Method for determination of moisture content in petroleum - Beidou satellite moisture detectorH-MS1204 Oil Handheld Petroleum Moisture Rapid Tester
Principle:This instrument utilizes the principle of microwave energy attenuation caused by the absorption of microwaves through matter.
Usage of moisture detector:
Gasoline, engine oil, diesel, transformer oil, various light oils
Crude oil, heavy oil, and residual oilCoal tar, tar
Lubricating oil, electrical oil, fuel oil, aviation gasoline
Instrument features:
Microwave measurement technology is not affected by the particles, colors, or any minerals contained in the product
Intelligent digital to analog conversion and related data processing, including temperature correction, etc
Less affected by mineralization degree
Can accurately determine the water content in various single component or multi-component mixtures
Technical parameters of moisture analyzer:
Test range: 0.01~100.0%
Repeat:+ 0.5%FS
Reaction rate:<10 ms=''>
Temperature:<120 ℃<>
Power supply: Powered by rechargeable batteries, each charge lasts for 8 hours continuously
L Chassis size: 500 × 400 × 200mm
Portable total weight:<6kg<>
Selection of Beidou satellite moisture sensor:
Category Name |
range |
resolution |
repeat |
main purpose |
MS1204N100 |
0~100.0% |
0.1% |
0~70%:&plun; 0.5%; 70~100.0%:&plun; 1.5% |
General oil water content test |
MS1204N60 |
0~60% |
0.1% |
0~60%:&plun; 0.5% |
General oil water content test |
MS1204N10 |
0~10% |
0.01% |
0~10%:&plun; 0.02% |
General oil water content test |
MS120ar |
0~100.0% |
0.05% |
0~70%:&plun; 0.5%; 70~100.0%:&plun; 1.5% |
Oil tanker inspection |
MS1204-Oil-01kit |
0~100.0% |
0.1% |
0~70%:&plun; 0.5%; 70~100.0%:&plun; 1.5% |
High water content in oilfield production |
MS1204-Oil-02kit |
0~100.0% |
0.1% |
0~70%:&plun; 0.5%; 70~100.0%:&plun; 1.5% |
High water content in oilfield production |
The MS1204 moisture sensor uses the principle of microwave energy attenuation caused by absorption when passing through a substance.
Due to the ratio of the absorption coefficient of moisture to that of oil75:1, when a high-frequency electric field is applied to oil products, the difference in absorption will affect the phase and amplitude of the high-frequency electric field, and the degree of influence is related to the moisture content.
The microwave attenuation moisture measurement instrument (humidity meter) represents a new development in product moisture measurement technology. By using microwave measurement technology, it can be used to measure moisture in productsThe moisture content can be determined within 1 second, and the measurement results are highly accurate and not affected by the particles, color, or any minerals contained in the product.
The MS1204W model can effectively eliminate the influence of oil quality and mineralization in the determination of crude oil water content in oil fields.
The HBD5MS1204 oil moisture rapid tester is a ppm level oil moisture tester developed by our institute, which can accurately determine the water content in various single component or multi-component mixtures.
HBD5-MS1204-CIL Oil Moisture Rapid Detector - Long Handle Probe Application Site Schematic:

Standing on the oil tanker, insert the sensor into the car to the bottom, turn on the power switch, and the display will show the water outlet score
Test probe selection:
MS1204N liquid type: 30cm sensor rod length, quick laboratory use
MS120ar long handle probe: 1.6m aluminum alloy rod length with scale. Design for on-site acceptance of heavy oil, crude oil tank trucks, etc
MS1204Dip liquid immersion type: extended cable to 6 meters suitable for depth testing, suitable for trains, oil tanks, and oil tankers
MS1204Pot Liquid Tank Tester: Designed specifically for measuring and testing oil tanks, it can be used for measuring tank trucks, storage tanks, oil tankers, etc
Method for determination of moisture content in petroleum - Beidou satellite moisture detectorH-MS1204 Oil Handheld Petroleum Moisture Rapid Tester
Comparison of various methods for measuring water content in crude oil:
distillation
Principle: Utilizing the principle of different boiling points and distillation times of crude oil, water, and solvents.
Disadvantages: Long distillation time, greatly affected by the accuracy of quality and volume measuring instruments, and the effect of circulating cooling.
Centrifugation
Principle: The principle of layering in a centrifuge by utilizing the density difference between crude oil and water
Disadvantages: Long distillation time, greatly affected by the accuracy of quality and volume measuring instruments, and the effect of circulating cooling.?
capacitance method
Principle: Utilize the difference in dielectric constant between crude oil and water.
Disadvantage: It is greatly affected by changes in the composition of the measured crude oil and electrolytes in water.
High frequency method
Principle: The principle of using different substances under the action of an electric field to absorb energy by electric dipoles during the transformation process, causing phase changes in electric field voltage and current.
Disadvantage: It is greatly affected by the conductivity of each component and electrolyte.
Coulomb method
Principle: The principle of utilizing the difference in the amount of electricity required for the electrolysis reaction between water and other substances.
Disadvantages: Long testing cycle, affected by dissolved oxygen content and component complexity.
Crude oil water content state:
Adding water and emulsifiers to the oil for emulsification cannot be achieved by distillation, but this instrument can detect it.
Adding salt or soil to the oil, this instrument also has the characteristic of positive response to water. If the true water content is not high,
It may be due to soil or other inorganic salt impurities.
Pure oil without water can be detected for quality, such as calorific value, using this instrument.
The purpose of accurately measuring oil samples in a mixed state of oil and water is only after thorough stirring.
At present, the analysis of crude oil water content in domestic oil production plants mainly adopts distillation and centrifugal separation methods, which are complex and time-consuming. In order to obtain a large number of oil samples in a timely manner, a large number of personnel are required.