Equipment Name: Beidouxing Ammonia Concentration Detector/Online TypeReal time monitoring and metering system for ammonia unloading concentration
Equipment model (specification) |
auxiliary equipment |
remark |
T-BD5CMD+EMC1204pR0.1-60T60 P1.6 |
Medium: ammonium chloride/water; Range: 0-27.1% w @ 20°C; Accuracy: 0.1% Accuracy: 1% FS Operating temperature:<60<>°C Connection method: DN32 flange installation, equipped with stainless steel positive flange; Liquid receiving material: 316L; Work pressure:<0.6mpa<> Protection level: IP65 Output: 4-20mA, four wire system Digital LCD display; Explosion proof type: Class II explosion-proof; Combustible gas: NH3; |
Suitable for legitimate manufacturers of chlorinated ammonia solution products; Impurity content not exceeding 0.35% |
BD4 Measurement Monitor |
|
|
Beidou Star Ammonia Concentration DetectorApplication: Limited to pure industrial water solutions or equivalent industrial process binary liquid concentration testing.
Limitations: Salt content variation system cannot be used; Salt content higher than 1000ppm cannot be used.
The common specifications of smart transmitters are as follows:
Non polar or weakly polar organic compounds and aqueous phase, or strongly polar and aqueous phase dual main component systems refer to
Model |
EMC1204p |
T-BD5CMD+EMC1204pc_R0.01-10T120 P1.6 |
T-BD5CMD+EMC1204p_R0.1-100T60 P1.6 |
T-BD5CMD+EMC1204p_R0.1-100T100 P1.6 |
T-BD5CMD+EMC1204p_R0.1-100T120 P1.6 |
T-BD5CMD+EMC1204p_R0.1-100T200 P1.6 |
T-BD5CMD+EMC1204pp_R0.05-10T120P1.6 |
*The number after R in the specification model is the range (%); The number after T isz高Liquid temperature(ºC); The number after P isz高Work pressure (MPa).
Characteristics of ammonia concentration detectorAdvantages
Maintain high sensitivity across the entire range
Storage tanks, pipelines, and reaction vessels can be directly inserted
Easy to install and use
Online testing for high accuracy and repeatability
No mechanical vulnerable parts, no maintenance
Application of Beidou Star Ammonia Concentration Detector
Petrochemical industry, constant concentration testing of organic liquids
Water phase liquid, slurry concentration testing
Concentration test of two-component mixture
Data Processor STIM Signal Processor
Processing unit:BD5xCD (standard, with on-site display)/BD5xC (without on-site display)
Power supply requirements:9-24v d.c. @ 100mA x5V (total power consumption of standard transmitter)
analog output: 0/4 - 20mA, Full, customizable
communication interfaceRS232 and R5422/485, IEEE1451.2 STIM smart transmitter standard protocol, supporting ModBus instrument network Other fieldbus supports can be ordered
Alarm/switch1 way photoelectric isolation power drive, 3A * 380V