PGAs 2000 + ofNatural gas calorific value detectorTechnical features:
Built in microcontroller microcomputer
Quickly detect parameters and temperature values, and perform temperature correction and cross correction
24 sets of data records, can be set to automatic or manual recording
RS232/485 duplex interface, capable of online sampling with microcomputers
Inert gas software zeroing, standard sample or substitute calibration
All operation keyboard settings, window prompts
The BD6 tester is an intelligent system with a built-in single-chip microcomputer. The system is designed with excellent hardware, including 2MB. All data can be saved in case of power failure. Each instrument provides professional analysis/testing techniques, maximizing the solidification of professional methods. Support DKA (dual standard method) standard sample or substitute calibration, as well as single point pure inert gas calibration. Provide cross interference gas correction mode.
Natural gas calorific value detectorUsage: Analysis of calorific value of natural gas and liquefied petroleum gas
Gas calorific value detectorofApplication:
Rapid detection of gas industry
Natural gas detection
Natural gas, gas field gas or * gas, petroleum gas, condensate gas field gas analysis
Rapid analysis of liquefied petroleum gas composition
Rapid analysis of the main components of coal gas
Analysis of the main components of coal mine gas
Combustible ice detection
PGas2000 NG gas calorific value detectorofFunction:
LCD 4 × 16 character rotating display of multiple environmental parameters
Over limit alarm, alarm limit can be set
RS232/RS485 communication interface supports serial communication and can be connected to a computer
Comes with a serial micro printer
100 sets of data records. Readable, output or print
Optional pump sampling or depressurization sampling
Can enhance gas filter columns or other filters
Users can also calibrate or calibrate themselves
Calculation of calorific value through whole component analysis

Technical specifications of pGas200 natural gas calorific value meter:
BD6 host test ADC resolution: 0.025% FS
BD6 host test repeatability accuracy: 0.05% FS
Electrochemical probe accuracy: ± 1-2% reading (general)
Long term stability:+/-10%/year (generally)
Analyzer response time:<10ms;
Probe response time:<1min;
Instrument usage environment: Temperature: -10 ℃ to 60 ℃; Humidity: 10% to 90% R (no condensation)
Instrument storage environment: temperature: 0 ℃~50 ℃; Humidity: 10% to 80% R (no condensation)
Electrochemical probe direct sampling: temperature: 0-40 ℃; Pressure:<1.1 kgf=''>
Power supply: 6V rechargeable battery
Continuous usage time:>24 hours per charge; The battery should be stored for one week.