Beidou Satellite Instrument w-MG200CWAWall mounted multi parameter toxic agent monitoring alarmAdvantages and Features:
Built in microcontroller microcomputer
intelligent control
quick response
data recording
Readable records
Alarm limit can be set/Adjust
Wall mounted multi parameter toxic agent monitoring alarmapplicationApplication
Civil air defense environmental monitoring
Monitoring and alarm of ventilation and air exchange in civil air defense engineering
Indoor air quality testingSuitable for monitoring air quality index in offices and other public places;
Air purification monitoring and control
Ventilation and air exchange monitoring and control
VOCs monitoring and emission control
Odor monitoring and emission control
Air quality supervision in production settings
Air toxicity testing at construction sites
Can detect toxic agents and gasesNeurotoxic agents, erosive agents, various phosphorus containing agents, organic gasesToxic gas, chlorine gas, phosgeneCyanohydrogenAmmonia gas, etcWait.
|
Typical Sensitive to Organic phosphorus gas:0.1-100ppm HD:0.02-20ppm L:0.02-20ppm GA,GB, GD,GF,GE, Vx,Ve, VG, VS,VR,HS,HD,HT,HN,Lewisite,M-1,MD , ED, DA, CDA, BZ, CN, CNS,PS, CN-PS/CNB,Adamsit, CN-DM,BA, CA, CD, |
|
organic gas, odorous substances Typical Sensitive to toluene:<1~30ppm<> hydrogen sulfide:<0.1~3ppm<> ethanol:<1ppm-30ppm<> ammonia:<1~10000ppm<> Hydrogen: 3ppm~99.99% Thiol sulfide and other sulfidesCSC:0.1-15ppm Ether ketone ester alcoholCOC:0.1-100ppm |
Technical performance parameters:
Sensitivity and response time of toxic agent alarm(Under normal temperature conditions)
Type of Toxic AgentNeurotoxic agents,
sensitivity(mg/m3) : 20
response time(s) :≤10S。
Type of Toxic AgentCorrosive toxic agents,
sensitivity(mg/m): 0.2 (Vieux 0.5),
response time(s) :≤30S。
environmental adaptability:
Operating Temperature:-20℃~~+40℃,
damp-heatAt 30 ℃,
relative humidity≤95%RH,
Shock and vibrationMeet the relevant requirements of national standards.
3)Continuous working hours shall not be less than24 hours (at room temperature).
Power indicator light:green
display device:2×16 LCD
Heat up time:60S
power consumption:300mW
power supply:220V AC or 12/24VDC
measurement resolution:24 digits
Communication interfaceRS485 interface
call the policefunction:buzzer/transfiniteLED lightDouble alarm
switch control:relay/0/5V
response timeT90:< 10s
Repetition accuracy:<<>±1%
temperature-20℃~50℃
Humidity:10%~90%RH
Sensor lifespan:~3 years