Welcome Customer !

Membership

Help

Beijing Beidouxing Technology Co., Ltd
Custom manufacturer

Main Products:

ag-mach>Products
Product Categories

Beijing Beidouxing Technology Co., Ltd

  • E-mail

    674338455@qq.com

  • Phone

    18611900152

  • Address

    Institute of Physics, Chinese Academy of Sciences, Zhongguancun, Haidian District, Beijing

Contact Now

Manufacturer of semi-automatic hydrogen purity analyzer

NegotiableUpdate on 05/18
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The pBD5GS-H2-R100 portable hydrogen purity analyzer (referred to as the hydrogen purity analyzer) is a portable gas analyzer used for the percentage content of hydrogen in mixed gases. It is widely used for daily detection of hydrogen purity in chemical plants, power plant hydrogen cooled generators, and hydrogen production stations. It can also be used for monitoring the hydrogen replacement process during the start-up and shutdown of hydrogen cooled generators, monitoring the percentage content of hydrogen in the environment, synthetic ammonia processes in fertilizer plants, and sewage treatment. The portable hydrogen purity analyzer overcomes the shortcomings of the "absorption method" and does not require pre extraction of gas samples. It can be directly carried to the sampling point on site and connected to a gas pipeline for testing. The instrument is powered by rechargeable batteries, with small size, light weight, simple operation, rapid response, and stable readings. The instrument testing accuracy is better than 0.1%, and the linearity is good.

Product Details

pBD5GS-H2-R100Portable hydrogen purity analyzer

name

Specifications

Sensors and their characteristics

range

Zui High Resolution

Repetitive accuracy

Remarks

Hydrogen purity analyzer

pBD5GS-H2-R100

3E4%

0~4%

4-100.0%Vol;

100ppm

<2%<>

<4%<>

Hydrogen purity analysis;

Simultaneously test humidity and temperature;



  • Built in microcontroller microcomputer

  • At any temperature, simply insert the sample and immediately read out the electrochemical gas parameters and temperature values

  • Sound and light alarm function, alarm limit can be set, solidified with TLV, S alarm database

  • 24 sets of data records, can be set to automatic or manual recording

  • RS232/485 duplex interface, capable of online sampling with microcomputers

  • Zero adjustment of inert gas, calibration of standard samples or substitutes

  • Supports two-phase analysis and can test dissolved gases

  • Multi meter calibration, supporting cross testing of multiple gases

  • All operation keyboard settings, window prompts


The H-BD5gs tester is an intelligent system with a built-in single-chip microcomputer and a well-designed hardware system. All data can be saved in case of power failure. Each instrument provides the most professional analysis/testing techniques and maximizes the solidification of professional methods. Capable of supporting fieldbus and RS232/485 communication interface. The BD5 tester enables most instruments to provide full range testing, eliminating the hassle of range selection.

The Beidouxing handheld sensor is ingeniously designed to be similar to general instruments, directly used for grinding bottles, or connected to pipelines with pipe threads for temporary continuous detection.

The H-BD5gs analyzer also supports cross gas single gas testing. That is to say, it can also be used for testing other gases in addition to the main gas being tested. Provide information on other measurable gases in the product documentation.

pBD5GS-H2-R100Portable hydrogen purity analyzerFeatures:

Unlike thermal conductivity concentration meters, this instrument has selectivity. In most mixed gases, it only responds to H2.

Application of hydrogen purity detector

Hydrogen leak detection, hydrogen purity analysis

Analysis of Hydrogen in Natural Gas

Simple gas analysis testing

Production safety monitoring

Widely used in scientific research, chemical plants, power plants, hydrogen cooled generators, and daily detection of hydrogen purity in hydrogen production stations. It can also be used for monitoring the hydrogen replacement process during the start-up and shutdown of hydrogen cooled generators, monitoring the percentage of hydrogen in the environment, synthetic ammonia processes in fertilizer plants, and sewage treatment.

Unsaturated hydrocarbons such as ethylene, hydrogen sulfide, alcohols such as isopropanol, and coal gas cannot be used.

Technical Specifications for Analyzer

Display: 2x16 LCD

Analyzer resolution: 24 bits (FS=+/-1280mV)

Sensor response time:<10s, Max<60s>

Environmental temperature: -30 ℃~70 ℃ (processor)

Environmental humidity: 0% to 90% R (processor)

Power supply: 9V rechargeable battery or DC 9V power supply

Continuous battery operation:>10 hours/voltage drop alarm

Processor size: 98W × 180H × 35D

The lower limit of temperature for general electrochemical sensors is -10 ° C. The upper limit is 40 or 50 ° C.

Safety level: intrinsic safety type

Chassis standard: IP10

Standard specifications:

General Technical Requirements for Gas Detection and Alarm Devices in Work Environment GB 12358-90;

PBD5GS-H2-R100 Hydrogen Purity Analyzer

Common professional application testers:

name

Specifications

Sensors and their characteristics

range

Zui High Resolution

repeatability accuracy

Remarks

Hydrogen gas detector

H-BD5GS-H2

4HYT

0~2000ppm

2ppm

<2%<>

Hydrogen explosion-proof leak detection

Hydrogen gas detector

pBD5gs-H2

4HYT

0~2000ppm

2ppm

<2%<>

Hydrogen explosion-proof leak detection

Hydrogen gas detector

H-BD5GS-H2

3E1%

0~1%;

20ppm

<2%<>

Hydrogen explosion-proof leak detection

Hydrogen gas detector

H-BD5GS-H2

3E4%

0~4%; 0-100.0%LEL

100ppm

<2%<>

Hydrogen explosion-proof leak detection

Hydrogen purity analyzer

pBD5GS-H2-R100

3E4%

0~4%

4-100.0%Vol;

100ppm

<2%<>

<4%<>

Hydrogen purity analysis;

Simultaneously test humidity and temperature;

Hydrogen purity analyzer

pBD5GS-H2+CO-R100

3E4%

H2:0~4%

4-100.0%Vol;

CO:0-100.0%

100ppm

<2%<>

<4%<>

Analysis of hydrogen concentration in mixed gas with CO;

Simultaneously test humidity and temperature;

Hydrogen purity analyzer

pBD5GS-H2R100+O2

3E4%


KE

0~4%

4-100.0%Vol;

0-100.0%

100ppm


0.1%

<2%<>

<4%<>

1%

Hydrogen purity analysis;

Oxygen content analysis;

Simultaneously test humidity and temperature;

Common cross interference data of sensors

3HYE 10-10000/20000

3HYT 2-1000/2000

Manufacturer of pBD5GS-H2-R100 Hydrogen Purity Analyzer:

Beijing Beidouxing Industrial Chemistry Research Institute

Beijing Beidouxing Technology Co., Ltd