Concrete ultrasonic testing instrumentSwiss imports:
Concrete ultrasonic UPV detector Pundit PL-200PE.
Pundit PL-200PE uses * pulse echo technology to expand the application of ultrasound programslimitObjects in unilateral contact.
Concrete ultrasonic testing instrumentSwiss imported innovative technologies have played an important role in the measurement process, such as echo tracking and automatic estimation of pulse velocity. The A-Scan mode can directly analyze raw signals, while the real-time B-Scan mode provides cross-sectional views. Area scanning supports performing plate thickness * testing in grid mode.
This allows users to determine the thickness of the cement board and identify the location of surface deformities such as voids, pipes, delamination, and honeycombs.
The control buttons and direct optical feedback on the detector improve measurement efficiency and make the instrument more user-friendly.
Features:
Single side measurement of cement board thickness
Gap, pipeline, layer and honeycomb detection and location determination
*The echo tracking technology helps identify the main echoes
Area scanning is suitable for conducting flat panel thickness * testing in grid mode
Measure the thickness variation of tunnel lining according to RI-ZFP-TU
The control buttons and direct optical feedback on the detector improve measurement efficiency
Automatic estimation of pulse velocity
Convenient B-Scan directly measure through the center mark and ruler on the detector
Dry contact sensor: No coupling agent required, suitable for measuring rough surfaces
Lightweight and in accordance with ergonomic principles when in use
Scalable pulse velocity sensor
attachment
| 50 kHz pulse echo sensor Pulse echo sensor is a transverse wave sensor that can be designed for single handed and/or dual handed operation. Especially suitable for detection with limited single side contact. |
|
Standard 54kHz sensor |
|
| 150kHz sensor These two sensors have higher resolution, but reduce the measurement range. Used for samples with finer particles. |
|
| 250kHz sensor These two sensors have higher resolution, but reduce the measurement range. Used for samples with finer particles. |
|
| 54kHz index sensor Used for rough surfaces without coupling agents. Used in conjunction with Pundit Lab+, no external amplifier is required. |
|
500kHz sensor |
|
| 250 kHz transverse wave transducer Used for material testing that combines the use of standard longitudinal wave transducers to measure dynamic elastic modulus. |
|
| sensor bracket Specially used for mixed measurements such as measuring surface velocity or crack depth. |
PL-Link
Download and save data on PC software for analyzing and exporting third-party applications.
application
| Pundit PL-200 | Pundit PL-200PE |
| Transmission through transmission: double-sided contact on both sides | Pulse echo: single side contact |
| Concrete quality assessment | |
| Ultrasonic pulse velocity | |
| uniformity | |
| Comprehensive method of compressive strength and SONREB ultrasonic rebound | Thickness of single-sided cement board |
| Determination of crack depth | Gap, pipeline, crack (parallel to the surface) and honeycomb detection and location determination |
| modulus of elasticity | |
| scanning mode | |
| A-Scan linear scan data recording Area scanning |
A-Scan B-Scan Area scanning |
standardization
The Pundit PL-200 ultrasonic testing equipment meets the following standards:
EN12504-4 (Europe)
ASTM C 597-02 (North America)
BS 1881 Part 203 (UK)
ISO1920-7:2004()
IS1311(印度)
CECS21 (China)
Technical data
| Pundit PL-200 | Pundit PL-200PE | |
| scope | 0.1 – 7930 μs | |
| resolution | 0.1 μs (< 793 μs), 1 μs (> 793 μs) | |
| monitor | 7 "color display screen with 800 x 480 pixels | |
| Pulse voltage UPV | 100 – 450 Vpp | |
| Pulse voltage UPE | - | 100 – 400 Vpp |
| bandwidth | 20 – 500 kHz | |
| Receiver gain | 1 x -10000 x (0-80dB) | |
| Memory: Internal | 8 GB flash memory | |
| Locale | Supports metric and imperial units | |
| battery | Lithium polymer, 3.6 V, 14.0 Ah | |
| Battery lifespan | >8h (in standard operating mode) | |
| Operating Temperature | 0 ° C-30 ° C (charging, operating instrument)/0 ° C-40 ° C (charging, instrument off)/-10 ° C-50 ° C (not charging) | |
| humidity | < 95 % RH, non-condensing | |
| IP rating | IP54 | |