E-mail
1658000156@qq.com
-
Phone
13916256554
-
Address
Jiading District, Shanghai
Shanghai Hansi Electromechanical Co., Ltd
1658000156@qq.com
13916256554
Jiading District, Shanghai
Three phase 30KW small gasoline generator

Generator monitoring communication interface: Whether it is on-site communication or remote communication, it must be achieved through the interface. Monitoring systems generally use serial communication. When using serial communication, data bytes are sent and received in sequence bit by bit. Serial communication can be divided into synchronous and asynchronous. When using synchronous serial communication, the agreement is made at the beginning of data transmission1~2A character is used as a synchronization indicator to achieve synchronization between the sending and receiving ends using a clock, while asynchronous serial communication involves transmitting data frame by frame. Due to the fixed format of each frame transmitted in asynchronous communication, the hardware structure is simpler than synchronous methods and can be corrected using check bits. So asynchronous communication is widely usedCRTTerminal, character printer, and telephone data communication.

At present, in regions with rapid economic development, it is necessary to construct commonly used generator sets with short construction cycles to meet the needs of users. This type of generator set generally has a larger capacity. Backup generator set. Under normal circumstances, the electricity required by users is supplied by the municipal power supply. When the municipal power supply is limited or interrupted due to other reasons, a generator set is set up to ensure the basic production and life of users.

| Parameters of a 30KW multi fuel generator set: | |
| Product Model | HS30REG / HS30REG-ATS |
| Rated peak power (GASOLINE) | 32KVA |
| Rated peak power (LPG) | 30KVA |
| Rated peak power (NG) | 29KVA |
| Rated voltage (V) | 230/400 |
| Rated current (GASOLINE) | 46.4 |
| Rated current (LPG) | 46.4 |
| Rated current (NG) | 43.5 |
| phase number | three-phase |
| Rated speed (rpm) | 3000 |
| power factor | 0.8 |
| Frequency (Hz) | 50 |
| Engine part number | LF481 |
| Displacement (cc) | 1587 |
| compression ratio | 9.5:1 |
| ignition system | ECM electronic ignition |
| electric start | yes |
| Starting motor specifications | QDY1205 12V 1.2KW |
| fuel type | GASOLINE/NG/LPG |
| Cylinder diameter x stroke (mm x mm) | L4-81×77 |
| breathing method | Naturally Aspirated |
| Engine oil capacity (L) | 3.5 |
| Rotary oil filter | yes |
| cylinder block | cast iron |
| cylinder liner | cast iron |
| Charging method | 14V/90A charging generator |
| Recommended Battery Cold Start Current (CCA) | 525A |
| Gasoline capacity (L) | 60 |
| number of cylinders | 4 |
| Continuous working time (h) | 8-10 hours |
| cooling system | Closed liquid cooling |
| High temperature shutdown | yes |
| Low oil pressure shutdown | yes |
| Type of AC generator | Synchronous generator, rotating magnetic field |
| pressure regulating system | AVR automatic voltage regulation |
| Excitation type | brushless |
| polar number | 2 |
| Total harmonic distortion @ full load | ≤ 5% |
| insulation class | H |
| Stator winding material | copper |
| Material of rotor winding | copper |
| Laminated materials (cold-rolled or hot-rolled) | cold rolling |
| connection method | Direct coupling (disc type soft connection) |
| motor bearing | 6306RS |
| voltage stability | |
| type | electron |
| Sensing | Single-phase [three-phase] |
| pressure regulation | ± 1% |
| Governor parameters | |
| type | electron |
| Frequency regulation from no-load to full load | synchronization |
| Steady-state frequency regulation | ± 0.5% |
| Controller installation location | Inside the chassis, above the motor |
| Manufacturer/Part Number | Zhongzhi/HSC940 |
| Auto/Manual/Off | yes |
| Generator voltage detection | yes |
| Mains voltage detection | none |
| Low oil pressure shutdown | yes |
| Low frequency protection | yes |
| High frequency protection | yes |
| crew | |
| 24/7 chassis | Powder coating cold rolling |
| Protection level | IP 23 |
| Emergency stop switch | have |
| Fuel solenoid valve | Dual solenoid valve |
| Closed type muffler | yes |
| grounding system | Rack grounding |
| Type of sound insulation device | Metal plate+soundproof cotton |
| Noise output dB (A) at 23ft (7M) during low-speed operation of the generator | 65 |
| Under the normal operation of the generator at full speed, the noise output at 23ft (7M) is dB (A) | 73 |
| GASOLINE consumption 50% load gal/hr (L/hr) | |
| GASOLINE consumption 100% load gal/hr (L/hr) | 13.7L/hr |
| NG consumption 50% load ft3/hr (m3/hr) | |
| NG consumption 100% load ft3/hr (m3/hr) | 10m3/hr |
| LPG consumption 50% load ft3/hr (kg/hr) | |
| LPG consumption 100% load ft3/hr (kg/hr) | 9.3kg/hr |
| NG intake pressure range kPa (in. H2O) | 1.3-2.7 (5-11) |
| LPG intake pressure range kPa (in. H2O) | 1.7-2.7 (7-11) |
| Unit size (length x width x height) in/mm | 61.4×35×38.19 / 1560×890×970 |
| Packaging dimensions (length x width x height) in/mm | 64.6×38.2×43.3 / 1640×970×1100 |
| Net weight (lbs/kg) | 460 |
| Gross weight (lbs/kg) | 500 |
| Loading capacity of 20/40 foot container | 12/28 |
| brand | HANSI HANSI |
| person in charge | Manager Cai |
Three phase 30KW small gasoline generator