50KW gasoline generator (230/400V)

NegotiableUpdate on 01/20
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The function of the spark plug of a 50KW gasoline generator (230/400V) is to introduce the high-voltage electricity generated by the ignition system (mainly the magneto) into the combustion chamber and generate an electric spark, which timely delivers the compressed combustible mixture in the gas cylinder. The final function of the ignition system is now working on the spark plug. The ignition system requires spark plugs for small gasoline generators. Spark plugs come into direct contact with high-temperature and high-pressure gases during operation, and they themselves carry high voltage. Therefore, they must have mechanical strength that can withstand high temperature and high voltage, as well as good insulation performance that can withstand high voltage.
Product Details

50KW gasoline generator (230/400V)

The function of spark plugs in gasoline generators is to connect the ignition system(Mainly magnetic motors)The generated high voltage electricity is introduced into the combustion chamber and generates electric sparks, which timely compress the combustible mixture in the gas cylinder. The final function of the ignition system is now working on the spark plug. The ignition system requires spark plugs for small gasoline generators. Spark plugs come into direct contact with high-temperature and high-pressure gases during operation, and they themselves carry high voltage. Therefore, they must have mechanical strength that can withstand high temperature and high voltage, as well as good insulation performance that can withstand high voltage.

Installation steps and methods for gasoline generator engines. After the maintenance and repair of the gasoline generator set, the components must be cleaned before installation. Installation should be carried out in the order of from inside to outside, and then disassembled and installed first. The steps and methods are to install the piston pin of the gasoline generator engine. The piston and connecting rod are connected by piston pins. Place the piston with the hinged hole in lubricating oil and heat it up until80-100At ℃, clamp the piston out and quickly insert the piston pin into the pin hole and connecting rod small head shaft hole(Note that the circular surface of the connecting rod big end should be aligned with the anti expansion cut of the piston in the same direction)Gently insert with a topper.

Parameters of HS50REG gasoline generator:
Product Model HS50REG/HS50REG-ATS
Rated peak power (GASOLINE) 50KVA
Rated voltage (V) 230/400
Rated current (GASOLINE) 99.5
phase number three-phase
Rated speed (rpm) 3600
power factor 0.8
Frequency (Hz) 50
Engine part number Q7
Displacement (cc) 2600
compression ratio 9.5:1
ignition system ECM electronic ignition
electric start yes
Starting motor specifications QDY1205 12V 1.2KW
fuel type GASOLINE/NG/LPG
Cylinder diameter x stroke (mm x mm) L4-81×77
breathing method Naturally Aspirated
Engine oil capacity (L) 3.5
Rotary oil filter yes
cylinder block cast iron
cylinder liner cast iron
Charging method 14V/90A charging generator
Recommended Battery Cold Start Current (CCA) 525A
cooling system Closed liquid cooling
High temperature shutdown yes
Low oil pressure shutdown yes
Type of AC generator Synchronous generator, rotating magnetic field
pressure regulating system AVR automatic voltage regulation
Excitation type brushless
polar number 2
Total harmonic distortion @ full load ≤ 5%
insulation class H
Stator winding material copper
Material of rotor winding copper
Laminated materials (cold-rolled or hot-rolled) cold rolling
connection method Direct coupling (disc type soft connection)
motor bearing 6306RS
voltage stability
type electron
Sensing Single-phase [three-phase]
pressure regulation ± 1%
Governor parameters
type electron
Frequency regulation from no-load to full load synchronization
Steady-state frequency regulation ± 0.5%
Controller installation location Inside the chassis, above the motor
Manufacturer/Part Number Zhongzhi/HSC940
Auto/Manual/Off yes
Generator voltage detection yes
Mains voltage detection none
Low oil pressure shutdown yes
Low frequency protection yes
High frequency protection yes
crew
24/7 chassis Powder coating cold rolling
Protection level IP 23
Emergency stop switch have
Fuel solenoid valve Dual solenoid valve
Closed type muffler yes
grounding system Rack grounding
Type of sound insulation device Metal plate+soundproof cotton
Noise output dB (A) at 23ft (7M) during low-speed operation of the generator 65
Under the normal operation of the generator at full speed, the noise output at 23ft (7M) is dB (A) 73
GASOLINE consumption 50% load gal/hr (L/hr)
GASOLINE consumption 100% load gal/hr (L/hr) 13.7L/hr
Unit size (length x width x height) in/mm 61.4×35×38.19 / 1560×890×970
Packaging dimensions (length x width x height) in/mm 64.6×38.2×43.3 / 1640×970×1100
Net weight (lbs/kg) 475
Gross weight (lbs/kg) 520
Loading capacity of 20/40 foot container 12/28
brand HANSI HANSI
person in charge Manager Cai