Y09-3016 handheld laser dust particle counter can directly detect clean environments with cleanliness levels ranging from one million to one hundred. It adopts a lightweight and sturdy high-pressure injection molding process plastic shell, which is easy to hold. Easily configure the instrument using the keyboard menu. Built in storage for up to 1000 particle records using points, which can be directly read on the screen or downloaded to software via USB port. Real time particle data from 6 particle size channels can be displayed simultaneously.
Y09-3016handheldLaser dustparticle counter
The laser dust particle counter can directly detect the cleanliness level
A clean environment ranging from one million to one hundred levels, using lightweight and sturdy high-pressure injection
Plastic shell made of plastic technology, easy to hold. Easy configuration using keyboard menu
Instruments. Built in storage up to 1000 A particle record using points, which
The data can be directly read on the screen or usedUSBDownload the software through the port.
Can display simultaneously 6 Real time particle data of individual particle size channels.
Widely used products
Can monitor biosafety,HVACSystem, computer room, beverage packaging environment,
Drugs, production environment, hospital clean operating room, car spray environment,
Production of microelectronics, biochemical products, food hygiene, fine chemicals, precision machinery, etc
The research department is responsible for the implementation of HVAC and pharmaceutical enterprises and their supervisory management departmentsGMP
Features and advantages
▪ Particle size range:0.3Mm, 0.5Mm, 1.0Mm,3.0Mm,5.0Mm,10.0Mm
▪ The traffic is0.1 CFM (2.83 L/min)
▪ display simultaneously6 A channel
▪ Compliant withISO14644-1TheGB50073-2001TheGMPTheFS-209Estandard
▪USBoutput
▪ Compatible with software
▪1000 A data memory
▪999 A testing location
▪LCDliquid crystaldisplay screen
▪ Display screen data reading
▪ Li-On rechargeable
▪ Chinese and English keyboard menu
▪ Display in both Chinese and English
▪ High impact plastic injection molding
▪ lightweight-only heavy1.3 lbs(0.58kg)
Technical Specifications:
light source |
Semiconductor laser with a lifespan of over 35000 hours |
sampling flow |
2.83L/min (0.1ft3) imported sampling pump |
display mode |
LCD display, real-time display, previous cycle display, real-time concentration display, can display time, date, measurement value, temperature and humidity, room number, sampling point, sampling frequency, battery level, status and other parameters, 95% UCL calculation, can directly display particle concentration (particles/cubic meter) |
Rechargeable battery |
Lithium ion battery, 7.4 V, 2200mAh |
power supply |
AC power adapter, AC: 100V~245V, 50/60 Hz to DC: 7.4V, 1A; |
working hours |
6 hours (remaining battery indicator) |
Counting mode |
Cumulative value, difference value, concentration value |
test method |
Single, repetitive, continuous, computational, remote |
unit conversion |
The unit can be converted into m3 |
Particle size channel |
0.3 、0.5、1.0、3.0、5.0、10μm, Simultaneously count six particle sizes |
sampling period |
1~10000(s),Delay count: 0-99 (S),Self purification time: ≤ 10 (min) |
working environment |
Temperature: 10-40 ℃ (50-104 ℉),Relative humidity: 20-90% RH, no condensation Atmospheric pressure: 86-106KPa |
Temperature and humidity: |
select (1) Temperature: 0-50 ℃± 1 ℃ (2) Humidity: 0~100%RH±5% |
UCL settings |
Sampling points (A): Set from 2 to 9 points. Sampling frequency per point: (L) 2-9 times set
Measurement position: 0-999
|
UCL report |
Compliant with ISO14644-1, GB50073-2001, GMP, FS-209E standards |
data storage |
It can store 1000 sets of data (circular buffer) (including particle size, data, environmental data, year, month, day, time, sampling volume, data location port), and the data will not be lost after power failure. |
communication interface |
RS232, 9600 baud rate |
Alarm Settings |
The instrument is equipped with a level alarm function, which can alarm when the cleanroom exceeds the standards of level 100, 1000, 10000, 100000, 300000, and 1000000Alarm for low battery voltage |
Zero Count |
Meets the requirements of JJG-547-88 Dust Particle Counter Verification Regulations JIS B9921:1997, with less than one count every five minutes |
Overlap error |
At 5%, 2000000 particles per cubic foot |
Print function |
External printer (optional) |
Overall dimensions |
230×130×45(mm) |
weight |
0.58kg |
calibration |
Traceable to the National Institute of Standards and Technology (NIST) in the United States, our company has passed the national metrology standard building assessment and can be traced back to the Shanghai Institute of Metrology and Measurement Technology. We can also calibrate ourselves or third-party national metrology institutions |
Standard Configuration |
Suitcase/charger, equal power sampling head, zero filter, RS 232 connection cable, computer connection communication software CDFactory inspection report, configuration list, instruction manual |
Optional parts |
External printer, professional triangular sampling rack |
warranty period |
One-year warranty |