The GC-90 gas chromatograph isShanghai gas chromatograph manufacturerShanghai Hui BranchnewA high-performance instrument produced. The instrument has a stylish appearance and beautiful design; Adopting a fully microcomputer control system with high precision and good stability; The LCD display screen is rich and intuitive in content, with a touch sensitive keyboard operation that facilitates users in setting various parameters. This machine has five detector options: FID, TCD, FPD, ECD, and NPD, and can simultaneously install three detectors and a methane converter.
GC-90Characteristics of gas chromatograph:
1. The instrument adopts a fully microcomputer control system, with a large screen LED display in both Chinese and English, providing rich and intuitive display content;
2. New digital design, highly integrated electronic circuit, excellent reliability, Chinese keyboard style operation, convenient parameter setting and operation.
3. The column box structure is compact, the layout is reasonable, the temperature is uniform, and the intelligent dual channel rear door design makes the cooling speed faster (from 280 ℃ to 50 ℃ in just 8 minutes), the efficiency is higher, and it can be stably controlled at room temperature of 5 ℃, expanding the application range of the instrument.
4. The instrument can be equipped with two packed column gasification chambers and one capillary gasification chamber simultaneously, as well as two capillary gasification chambers simultaneously, and can be expanded from a single amplifier to a dual amplifier. According to different analysis applications, different combinations can be used to install up to three detectors simultaneously, such as FID, TCD, ECD detectors, etc. Can easily achieve the series and parallel operation of detectors. Truly achieving one machine with multiple uses.
5. The instrument can be equipped with capillary columns of different specifications (caliber 0.2-0.53MM), and its reasonable capillary injection system design (with split/non split injection, diaphragm blowing, and tail blowing systems) makes the out of column effect small and the column efficiency high; To achieve a peak shape with high chromatographic peak height, narrow half peak, and no tailing, thus obtaining accurate and good repeatability quantitative results.
6. The instrument adopts a modular design, making installation simple and maintenance more convenient; The new FID has a lower detection limit and can be easily disassembled and cleaned for the nozzle and ion collection electrode.
7. The gas path adopts a dual design of stabilizing pressure first and then temperature flow; Stable regulation mode, with high precision, high reliability, and convenient and intuitive flow regulation. Equipped with gas/gas leakage protection and prompt function, it can automatically cut off TCD bridge current and protect rhenium tungsten wire from damage.
8. Equipped with a six channel temperature control system, including column chamber, gasification chamber, detection chamber, converter, and external control events.
9. It has a nine order linear program heating function, which can meet the analysis of multi-component samples.
10. It has power-off protection, over temperature protection, and power on self-test functions.
Shanghai gas chromatograph manufacturerInstrument application technology:
Organic chlorine pesticide residue detection
Detector: ECD detector;
Sample injector: capillary injection system;
Chromatographic column: Pesticide residue No.1 30m * 0.53mm * 1.0um
出峰顺序: 1.α-BHC; 2.β-BHC; 3.γ-BHC; 4.δ-BHC; 5.PP`-DDE;
6. PP`-DDD; 7.OP`-DDT; 8.PP`-DDT;
Chromatographic conditions: column temperature of 240 ℃, gasification chamber of 280 ℃, detector of 300 ℃.
Oxygenated compounds in gasoline
Detector: FID detector;
Sample injector: capillary injection system;
Automatic ten way valve cutting system
Peak order: 1. Methanol; 2. Ethanol; 3. Isopropanol; 4. tert butanol; 5. n-propanol; 6.mtbe;
7. sec butanol; 8. Diisopropyl ether; 9. Isopropanol; ten Ethyl tertiary ether;
11. tert pentanol; 12. Ethylene glycol dimethyl ether; 13. n-butanol; 14. tert amyl methyl ether.
Gas Analysis in Gas Process
Detector: TCD detector;
Injector: Six way valve injection system;
Automatic six way valve cutting system
Peak order: 1. Carbon dioxide; 2. Ethylene; 3. Ethane; 4. Oxygen; 5. Nitrogen; 6. Methane;
7. Carbon monoxide.
Technical Cresol
Detector: FID detector;
Sample injector: capillary injection system;
Peak order: 1. Benzene fraction; two 2,6-dicresol; 3. o-cresol; 4. p-cresol; 5-cresol;
6.2,4-dicresol; 7.2,5-dicresol; 8.3,5-dicresol; 9.3,4-dicresol.
Standard sample of Baijiu
Detector: FID detector;
Sample injector: capillary injection system;
Peak order: 1. Acetaldehyde; 2. Methanol; 3. Ethanol; 4. Ethyl acetate; 5. n-propanol; 6. sec butanol;
7. Isobutanol; 8. Acetal; 9. n-butanol; 10. Isopentanol; 11. Ethyl butyrate;
12. Internal standard substance; 13. Butyl acetate; 14. Ethyl valerate; 15. Ethyl lactate;
16. Ethyl caproate.
Central control analysis of fuel grade dimethyl ether
Detector: TCD detector;
Injector: Six way valve injection system;
Peak order: 1. Air+carbon monoxide+methane; 2. Carbon dioxide; 3. Ethylene; 4. Ethane;
5. Propylene+Propane; 6. Dimethyl ether; 7. Water.
Multidimensional Chromatography Application Technology
Analysis of Trace Impurities in Ethylene and Propylene
Trace amounts of carbon monoxide, carbon dioxide, and acetylene are present in ethylene and propylene (acetylene detection does not require a conversion furnace),
GC-90 gas chromatograph, FID detector, methane converter, automatic ten way valve, can detect trace amounts of hydrogen in ethylene and propylene by simply replacing the TCD detector.
Analysis of Aromatic Hydrocarbons in Gasoline
GC-90 gas chromatograph
FID detector, capillary sampler, automatic ten way valve,
Chromatography column: TCEP pre cut column 0.56m × 0.38mm
Methyl silicone quartz capillary column: 30m × 0.53mm × 5.0um
Gas analysis of coal coking process
GC-90 gas chromatograph, dual TCD detector, ten way valve injection, automatic six way valve switching,
Determination of components: hydrogen, oxygen, nitrogen, methane, ethane, ethylene, acetylene, propylene, propane, carbon monoxide, carbon dioxide
Analysis of the entire composition of coal gas
GC-90 fully automatic gas chromatograph
FID detector, dual TCD detector, gas injection pump, three valve linkage,
Complete analysis of hydrogen, oxygen, nitrogen, methane, ethane, ethylene, acetylene, propylene, propane, carbon monoxide, carbon dioxide, benzene, toluene, xylene, and naphthalene in gas with a single injection.
Refinery gas analysis
GC-90 gas chromatograph, FID detector, TCD detector, three valve linkage.
One injection analysis of oxygen, nitrogen, methane, ethane, ethylene, acetylene, propylene, propane, carbon monoxide, carbon dioxide, hydrogen sulfide, carbonyl sulfide, n-butane, isobutane, n-pentane, isopentane and other components.
Gas detection in coal to oil process
GC-90 gas chromatograph, dual column chamber, FID detector, TCD detector, four valve linkage.
One injection analysis of hydrogen, oxygen, nitrogen, methane, ethane, ethylene, acetylene, propylene, propane, carbon monoxide, carbon dioxide, hydrogen sulfide, n-butane, isobutane, n-pentane, isopentane and other components.
Natural gas or refinery gas testing
GC-90 gas chromatograph, dual column chamber, FID detector, dual TCD detector, five valve linkage, seven chromatographic columns.
One injection analysis of hydrogen, oxygen, nitrogen, methane, ethane, ethylene, acetylene, propylene, propane, carbon monoxide, carbon dioxide, hydrogen sulfide, carbonyl sulfide, n-butane, isobutane, n-pentane, isopentane and other components in natural gas or refinery gas.