Product application:
With the development of computer technology and large-scale integrated circuit technology, instrument technology is striving towards high precisionSmall scale development. The US-8Y/US8300 displacement transmitter adopts large-scale integrated circuits to integrate the massive secondary instrumentsThe circuit and preamplifier adjustment circuit are miniaturized into one, and the displacement and vibration signals of the eddy current sensor are transmitted through the transmitterLinearization and normalization are used to output a 4-20mA standard signal, which is then sent to the DCS or PLC system for processing to achieve a rotating machineMeasurement of displacement or vibration of the mechanical axis.
1. Usage requirements
US-8Y/US8300 displacement transmitter collects displacement/voltage or current signals from eddy current sensors, and interacts with eddy current probesExtend cable connection,
The transmitter is installed in an explosion-proof or waterproof protective box in the low vibration and low temperature area of the unit site
2. Fault monitoring
US-8Y/US8300 transmitter monitors the radial displacement of rotating machinery rotors
3. Unit type
Various rotating machinery, such as gas turbines, blowers, compressors, electric pumps, etc
TECHNICAL INDEX:
US-8Y/US8300B displacement transmitter
External power supply: 24V
Full range output: 4~20mA
GAP voltage output: 1-5V
Measurement error:<1% (F · S)
Environmental indicators: temperature -25 ℃~60 ℃, humidity<80%
Dimensions: 100mm × 76mm × 47mm
Installation size: (60-90) mm × 63mm
Weight: 0.6kg
US-8Y/US8300Z amplitude transmitter
External power supply:+24V
Frequency response: 5Hz~5kHz (-3dB)
Full range output: 4-20mA
GAP voltage output: 2-10V
Measurement error:<1% (F.S)
Environmental indicators: temperature -25 ℃~60 ℃, humidity<80%
Dimensions: 100mm × 76mm × 47mm
Installation size: (60-90) mm × 63mm
Weight: 0.6kg
Measurement system: