E-mail
zhangminmin@dalton-corp.com
-
Phone
13162746417
-
Address
515 Yi'an Business Building, Qinzhou Road, Xuhui District, Shanghai
Shanghai Daotong Application Technology Co., Ltd
zhangminmin@dalton-corp.com
13162746417
515 Yi'an Business Building, Qinzhou Road, Xuhui District, Shanghai
Two minute sample analysis time
Detect samples extracted discretely, or can be connected to Sievers automatic sampler for large-scale sample analysis
Automatically perform calibration, validation, and data analysis operations
The reagent adaptive function can automatically determine the optimal flow rate for each sample
Very suitable for various sample matrices and concentrations
Very little preventive maintenance (usually only a few hours per year)
12-month calibration stability period
Optional "Stage 1" conductivity testing capability for synchronous detection of TOC and conductivity
Optional Turbo acceleration mode, analysis time only takes 4 seconds
Operating specifications* | |
|---|---|
| scope | 0.03 ppb to 50 ppm |
| Precision and accuracy | < 1% RSD |
| accuracy | ± 2% or ± 0.5 ppb (whichever is higher) |
| Display reading | 3 significant digits |
| Sample Type | Automatic sampler or discrete sample aspiration |
| calibration | The usual stable period is 12 months |
| analysis time | 2 minutes (4 seconds when using the optional Turbo mode) |
| Sample temperature | 5-95 °C(41-203 °F) |
| ambient temperature | 5-40 °C(41-104 °F) |
| Instrument samples flow velocity |
0.5 mL/min |
Analyzer specifications | |
| output | USB device port (1); USB host port (3); Modbus TCP/IP |
| display | 7 'WVGA 800x480 pixel, color LCD touch screen |
| electricity | 100 - 240 V~,50 - 60 Hz,100 VA |
| fuse | Replace the same type and size of fuse: T 1.6 A 250 VAC fuse (slow melting), size 5 X 20 mm electrical socket |
| size | H: 42.2 cm(16.6 in),W: 24.6 cm(9.7 in),D: 40.0 cm(15.8 in) |
| weight | 9.4 kg(20.6 lb) |
| Safety Certification | ETL, CE (see conformity declaration) |
Sample conductivity (optional) | |
| Initial conductivity range | 0.01 to 2000 μ S/cm |
| Conductivity accuracy | ± 0.005 μ S/cm or ± 1% (whichever is higher) |
| Precision and accuracy | <0.25% rsd=''> |
environment | |
| High relative humidity | 0-95%, no condensation |
| High altitude | 3,000 m(9.800 ft) |
| pollution level | 2 |
| The UV lamp in this product contains mercury and must be recycled or disposed of in accordance with local, state, and federal laws. | |
*The analytical performance can be achieved under controlled laboratory conditions, minimizing operational and standard errors to the greatest extent possible. | |
Sievers automatic sampler: 63 or 120 sample positions capacity
Data Pro 2 software: custom sampling protocol, automatic calibration and verification protocol
DataGuard softwareProvide compliance support for 21 CFR Part 11 and Appendix 11
Inorganic carbon remover (ICR):Improve the accuracy of TOC in samples with high inorganic carbon content
Sample conductivityDetect and report the conductivity of the sample
Turbo acceleration mode:Provide a 4-second analysis time