The ORT-12 constant temperature aging room, also known as the burning room, is one of the commonly used aging testing equipment, widely used in fields such as computers, mobile phones, power supplies, cooling fans, LED displays, power monitoring boxes, lithium batteries, electronics, and communications. Aging cabinets are usually constructed from enclosure structures, air duct systems, control systems, indoor testing racks, and other components.
Constant temperature aging roomAlso known as the burning room, it is one of the commonly used aging testing equipment, widely used in fields such as computers, mobile phones, power supplies, cooling fans, LED displays, power monitoring boxes, lithium batteries, electronics, and communications. Aging cabinets are usually constructed from enclosure structures, air duct systems, control systems, indoor testing racks, and other components. The aging chamber has the following main characteristics:
The design and control system of the air duct system in the aging room can maintain uniform temperature throughout the cabinet, with accurate control and high precision.
The indoor temperature range for high-temperature aging is wide, ranging from room temperature to 70 degrees CelsiusIt can be continuously adjusted within the temperature range.
The system has complete protection functions, which can ensure safe and long-term stable operation.
The constant temperature aging chamber is detachable except for the chassis, making it convenient for transit transportation.
Constant temperature aging roomMain technical specifications:
1、 Main technical parameters:
Temperature range: RT+5~70℃
Temperature fluctuation: ±1.0℃
Temperature accuracy:± 3.0 ℃ (measured under no-load conditions)
Heating time: RT~7About 30 minutes at 0 ℃
Internal volume: approximately12m3
Interior dimensions:3000×2000×2000mm (depth x width x height)
Overall dimensions:3400×2100×2100mm (depth x width x height) (width does not include the size of the electrical control box)
Heating power: about 9KW
Power supply: 380V 50HZ
IILarge constant temperature aging roomMain features and materials
1. Room material: The entire aging roomThe five sided enclosure structure consists of insulated color steel rock wool sandwich panels and aluminum profilesedge bindingComposed by combination; The electric control box is made of cold-rolled steel plate baked paint and placed in the front right of the aging chamber for easy operation.
2. According to the customer's aging requirements, it can be done in the aging roomsideThe department has opened a test hole of ¢ 50mm, in the lead holeFor high-temperature agingWhen aging indoor products are powered on, they serve as a power sourceUsed for wiring.
3. The insulation layer thickness of the aging area chamber is 50mm.
4. The constant temperature aging chamber adopts a double door design, with a large glass observation window installed on each door for easy viewing of the condition of the test sample during aging
5. Air duct system: composed of a circulating air system and an exhaust system; The blower motor is located in the aging roomrear sideAt the top, the air duct is locatedafterOn the side, the heating tube is located inside the air duct; The exhaust motor is located at the top. agingcabinetAfter being heated by the heater, the internal circulating air is sent back to the room through the air outlet by the air supply fan, and this process is repeated to maintain the temperature in the aging room within the set range. When the temperature inside the aging room exceeds the alarm set value, the exhaust fan starts to remove the overheated gas inside the room, and at the same time, the outdoor cold air is replenished and mixed with the indoor hot air to restore the indoor space temperature to normal.
6. Control system: Adopting imported high-precision microcomputer PID temperature controller, LED display, PID regulation, solid-state relay output, control accuracy of 0.1. The control system of the high-temperature aging chamber adopts a two-stage PID to regulate the heating amount, achieving control of the indoor temperature. The control system also implements multiple protection functions such as leakage, phase loss, and fan overload. The comprehensive protection functions ensure agingcabinetCan operate stably for a long time.