E-mail
15164162483@139.com
-
Phone
18940682483
-
Address
No. 6-84 Shengshi New City, Ziming Street, Linghe District, Jinzhou City, Liaoning Province
Jinzhou Jintai IoT Technology Co., Ltd
15164162483@139.com
18940682483
No. 6-84 Shengshi New City, Ziming Street, Linghe District, Jinzhou City, Liaoning Province
26GHz radar water level gauge
model:DC-6610/6611

eye record
1、productprinciple..............................................................................................1
2、Application characteristics of water conservancy industry.............................................................................1
3、Instrument Introduction...................................................................................2
4、instrumentinstall........................................................................................3
5、electrical connection........................................................................................4
6、instrumentdebug.........................................................................................5
7、structural dimensions........................................................................................6
8Technical parameters.........................................................................................8
9、Instrument linearity.........................................................................................9
10Product selection.........................................................................................10
1. Product principle
26GHz radar water level gaugeThe radar water level gauge antenna emits extremely narrow microwave pulses, which propagate at the speed of light in space. When they encounter the surface of the measured medium, some of their energy is reflected back and received by the same antenna. The time interval between transmitting and receiving pulses is proportional to the distance from the antenna to the surface of the measured medium. Due to the propagation speed of electromagnetic waves *, it is difficult to confirm the time interval between the transmitted pulse and the received pulse, which is very small (nanosecond level),90Xseries26GThe radar water level gauge uses a special demodulation technique that can accurately identify the time interval between the transmitted and received pulses, thereby further calculating the distance between the antenna and the surface of the measured medium.
A. Range setting
B. Low level adjustment
C. High level adjustment
D. Blind area range

2. Application characteristics of water conservancy industry
The industry recommended radar water level gauge adopts26GHzThe emission frequency has:
lSmall beam angle, concentrated energy, and stronger resistance to impactStrength greatly improves measurement accuracy and reliability
lThe antenna size is small, making it easy to install and install antenna protection devices such as dust covers
lLightweight approximately1KGEasy to install
lMeasurement range can reach70Meter, covering large reservoirs and other water level measurements
lMultiple output circuit interfaces and integration with acquisition systems
lAdopting a pulse working mode, the radar water level gauge has an extremely low transmission power and is harmless to both the human body and the environment
The reference surface for measurement is the bottom surface of the thread or the sealing surface of the flange
Note: Use radarwaterTiming must be ensuredliquidCannot enter the measurement blind zone (as shown in the figure)DThe area shown.
3Instrument Introduction
lDC-6610

should Use: Rivers, lakes, and shallow waters
Measuring range 30rice
Process connection: threadG1?? A /support/flange
Process temperature: -40~100℃
Process pressure: atmospheric pressure
essence Degree: ±3mm
Frequency range: 26GHz
Protection level: IP67 / IP65
Power supply:DC(6—24V)/four lines
DC 24V /Two lines
Signal output:RS485/ModbusAgreement(6~24V DC)
0mA/HartTwo lines(24V DC)
On site display: optional
outside Shell: aluminium/plastic
.DC-6611

should Use:Rivers, lakes, and shallow waters
Measuring range70rice
Process connection:threadG1?? A /support/flange
Process temperature:-40~100℃
Process pressure: atmospheric pressure
essence Degree:±10mm
Frequency range:26GHz
Protection level:IP67 / IP65
Power supply:DC(6—24V)/four lines
DC 24V /Two lines
Signal output:RS485/ModbusAgreement(6~24V DC)
4~20mA/HartTwo lines(24V DC)
On site display: optional
outside Shell: Aluminum/plastic
4. Instrumentinstall
?Preparation before installation Please pay attention to the following items to ensure that the instrument can be installed correctly:
Please reserve sufficient installation space.
Please avoid installation environments with strong vibrations.
?Illustration and installation location

Radar and bracket installation diagram (1)

Radar and bracket installation diagram (II)
Note: When radar antennas emit microwave pulses, there is a certain emission angle. There shall be no obstacles between the lower edge of the antenna and the surface of the measured medium, as well as within the area radiated by the emitted microwave beam. Therefore, during installation, it is necessary to avoid obstructing facilities as much as possible, and if necessary, "false echo learning" should be carried out. When installing instruments, attention should also be paid to: the liquid level should not enter the measurement blind zone; the instrument must be grounded, and lightning protection measures should be added; outdoor shading and rainproof measures should be taken.
5electrical connection
power supply voltage
RS485/Modbus Power supply andModbusThe signal lines are separated and each uses a shielded cable. The specific power supply voltage range can be found in the technical data.
(4~20) mA/HART(Two wire system) The power supply and output current signal share a two core shielded cable. Please refer to the technical data for the specific range of power supply voltage. For intrinsic safety type, a safety barrier must be added between the power supply and the instrument.
connection method
RS485/ModbusThe wiring diagram is as follows:

24VThe two-wire wiring diagram is as follows:

safety guidance
Please comply with the requirements of the local electrical installation regulations!
Please comply with local regulations on personnel health and safety. All operations on the electrical components of instruments must be completed by professionals who have received formal training.
Please check the nameplate of the instrument to ensure that the product specifications meet your requirements.Please ensure that the power supply voltage meets the requirements on the instrument nameplateoneTo.
Protection level
This instrument * protection levelIP66/67Please ensure the waterproof performance of the cable sealing head. As shown in the figure below:

How to ensure installation meetsIP67Requirement:
Please ensure that the sealing head is not damaged.
Please ensure that the cable is not damaged.
Please ensure that the cables used comply with the requirements of electrical connection specifications.
Before entering the electrical interface, bend the cable downwards to ensure that water does not flow into the housing, see①
Please tighten the cable sealing head, see②
Please seal the unused electrical interfaces with blind plugs, see③
6Instrument debugging
There are two radar water level gaugesDebugging methods:
⑴ Display/button
⑵ Upper computer debugging
display/Button
By displaying on the screen4Use one button to debug the instrument. The language of the debugging menu is optional. After debugging, it is usually only used for display, and the measured values can be read very clearly through the glass window.
①LCD (Liquid Crystal Display)
② Button

7structural dimensions Unit mm
lwatch caseSize:

.Overall Dimensions
DC-6610

DC-6611

lConnection method:
2 Standard bracket connection
2 Connection with rain cover bracket
2 thread G1?″Aconnect
2 G1Install the base connection

8Technical Specifications
|
outside shell Sealing between the outer shell and the outer shell cover silicone rubber Shell window polycarbonate grounding terminal stainless steel |
|
power supply voltage fourlinear system (6~24) V DC / RS485 Modbus /Power consumption 90mW Two linesmanufacture DC 24V / 4~20mA /Power consumption 0.75W
Allow ripple -<100hz> Uss - (100~100K) Hz Uss |
|
cable parameters Cable entry/plug M20xl.5cable entry terminal block Cross-sectional area of conductor1.0mm2 |
|
output parameters output signal RS485 Modbus / 4~20mA communication protocol Modbus / Hart resolution 1. 6u A fault signal The current output remains unchanged; 20. 5mA 22mA; 3.9mA integration time 0~36)s, adjustable |
blind spot Antenna end |
|
measure distance 908 30rice 909 70rice |
Microwave frequency 26GHz |
Measurement interval approximately1Seconds (depending on parameter settings) |
adjust the time approximately1Seconds (depending on parameter settings) |
display resolution 1mm |
Working storage and transportation temperature (-40~70)℃ |
Process temperature (temperature of antenna section) (-40~100℃ |
press力 atmospheric pressure |
seismic resistance Mechanical vibration l0m/s2 , (10~150)Hz |
9Instrument linearity
DC-6610
Launch angle Depends on antenna size
-¢76mm 12°
-¢96mm 8°
precision See the figure below

DC-6611
Launch angle Depends on antenna size
-¢76mm 12°
-¢96mm 8°
-¢121mm 6°
precision See the figure below

10. Productselection
Model:DC-6610
license
PStandard type (non explosion proof)
Process Connection/Materials
GThreadG1?″ A /Stainless steel304
NStandard bracket
MBracket with rain cover
H G1Install the base
YSpecial Customization
Antenna type/material
A horn antenna Φ 76mm/Stainless steel304
B horn antenna Φ 96mm/Stainless steel304
YSpecial Customization
seal/Process temperature
V Ordinary seal/(-40~100)℃
electronic unit
VRS485/Modbus /four-wire system
W(4~20)mA / 24V DC two-wire system
shell/Protection level
L aluminium/IP67
G plastic /IP65
cable inlet
M M20 x l. 5
N ?″ NPT
on-site display/programming
A belt
X without
Model:DC-6611
license
PStandard type (non explosion proof)
Process Connection/Materials
GThreadG1?″ A /Stainless steel304
NStandard bracket
MBracket with rain cover
H G1Install the base
YSpecial Customization
Antenna type/material
A horn antenna Φ96mm/Stainless steel304
B horn antenna Φ121mm/Stainless steel304
YSpecial Customization
seal/Process temperature
V Ordinary seal/(-40~100)℃
electronic unit
VRS485/Modbus /four-wire system
W(4~20)mA / 24V DC two-wire system
shell/Protection level
L aluminium/IP67
G plastic /IP65
cable inlet
M M20 x l. 5
N ?″ NPT
on-site display/programming
A belt
X without