E-mail
2954198810@qq.com
-
Phone
13651667376
-
Address
Room 3661, No. 13, Lane 65, Huandong 1st Road, Fengjing Town, Jinshan District, Shanghai
Shanghai Huifen Scientific Analysis Instrument Co., Ltd
2954198810@qq.com
13651667376
Room 3661, No. 13, Lane 65, Huandong 1st Road, Fengjing Town, Jinshan District, Shanghai
SGE injection needle 002810 10F-AG-0.63It is a gas-phase pointed injection needle with a specification of 10ul. The SGE injection needle 002810 has a conical tip to reduce damage to the injection pad, making it an ideal choice for automatic injectors.
SGE injection needle 002810 10F-AG-0.63Introduction
Before use, be sure to check the syringe for cracks and burrs on the needle tip.
Press the plunger until the correct volume is reached. Bring back the plunger and wipe the needle tip with a cotton free tissue.
To ensure accuracy, the Z small injection volume of the syringe should not be less than 10% of its total capacity.
To remove bubbles, rotate the syringe vertically, attach one side of the barrel, remove the bubbles, and then discharge them from the syringe.
To eliminate carryover between samples, rinse the syringe with solvent 5-20 times and remember to discard the first 2-3 washes.
SGE injection needle ordering information:
| volume | Needle length (mm) | label | Outer diameter (mm) | Needle tip type | Order Number |
| Agilent 7670 replaceable needle | |||||
| 1μL | 42 | 23 | 0.63 | taper | 000585 |
| Agilent 7673、 7683 and 6850 ALS fixed needle - straight tube type | |||||
| 5μL* | 42 | 26 | 0.47 | taper | 001800 |
| 5μL(M)* | 42 | 23 | 0.63 | taper | 001810 |
| 10μL* | 42 | 26 | 0.47 | taper | 002800 |
| 10μL(M) | 42 | 23 | 0.63 | taper | 002810 |
| 10μL(M)airtight | 42 | 23 | 0.63 | taper | 002812 |
| Fixed needle - tapered cone | |||||
| 5μL* | 42 | 23 – 26 | 0.63/0.47 | Tapered cone shape | 001821 |
| 10μL* | 42 | 23 – 26 | 0.63/0.47 | Tapered cone shape | 002821 |
| 10 μ L airtight* | 42 | 23 – 26 | 0.63/0.47 | Tapered cone shape | 002826 |
| 25 μ L airtight | 42 | 23 – 26 | 0.63/0.47 | Tapered cone shape | 003668 |
| 50 μ L airtight | 42 | 23 – 26 | 0.63/0.47 | Tapered cone shape | 004668 |
| 100 μ L airtight | 42 | 23 – 26 | 0.63/0.47 | Tapered cone shape | 005668 |
| Fixed Needle - SuperFleXTM Elastic Anti Folding Push Rod | |||||
| 10μL* | 42 | 26 | 0.47 | taper | 002830 |
| 10μL* | 42 | 23 | 0.63 | taper | 002835 |
| Interchangeable needle - straight tube type | |||||
| 0.5μL# | 42 | 26 | 0.47 | taper | 000400 |
| 0.5μL(M) # | 42 | 23 | 0.63 | taper | 000410 |
| 1μL# | 42 | 23 | 0.63 | taper | 000610 |
| 5μL | 42 | 26 | 0.47 | taper | 001805 |
| 5μL(M) | 42 | 23 | 0.63 | taper | 001815 |
| 10μL | 42 | 26 | 0.47 | taper | 002805 |
| 10μL(M) | 42 | 23 | 0.63 | taper | 002815 |
| 10 μ L airtight | 42 | 26 | 0.47 | taper | 002817 |
| 10 μ L (M) airtight | 42 | 23 | 0.64 | taper | 002818 |
| 25μL(M) | 42 | 23 | 0.63 | taper | 003665 |
| 50μL | 42 | 23 | 0.63 | taper | 004665 |
| 100μL | 42 | 23 | 0.63 | taper | 005665 |
| 250μL | 42 | 23 | 0.63 | taper | 006665 |
| Swappable needle - tapered cone | |||||
| 0.5μL# | 42 | 23 – 26 | 0.63/0.47 | Tapered cone shape | 000415 |
| 5μL | 42 | 23 – 26 | 0.63/0.47 | Tapered cone shape | 001825 |
| 10μL | 42 | 23 – 26 | 0.63/0.47 | Tapered cone shape | 002825 |
| 10 μ L (M) airtight | 42 | 23 – 26 | 0.63/0.47 | Tapered cone shape | 002829 |
| Swappable Needle - SuperFlexTMElastic anti folding push rod | |||||
| 10μL | 42 | 26 | 0.47 | taper | 002844 |
| 10μL | 42 | 23 | 0.63 | taper | 002845 |
(M) Suitable for Merlin Microseal sampler; *Multiple units can be ordered;
#Replace the needle; Replace the push rod item number; Replace the needle core without dead volume.
Cleaning of injection needle
Syringe cleaning agents typically rely on pollutants, with methanol and acetonitrile being commonly used cleaning solvents.
After cleaning the syringe, rinse it thoroughly.
Do not immerse the entire syringe in solvent, as this may damage the adhesive used to bond the syringe components.
Wipe the exterior clean with tissue. Disinfection methods:
-Autoclave: Remove the plunger from the barrel before high-pressure sterilization. Set the high-pressure vessel to the Z high temperature for removing needle syringes100℃, the high temperature of Z for fixed needle syringes is70℃. Before inserting the plunger into the barrel, allow the syringe to reach a certain temperature.
Gas: Use ethylene oxide.