Welcome Customer !

Membership

Help

Shanghai Huifen Scientific Analysis Instrument Co., Ltd
Custom manufacturer

Main Products:

ag-mach>Products
Product Categories

Shanghai Huifen Scientific Analysis Instrument Co., Ltd

  • E-mail

    2954198810@qq.com

  • Phone

    13651667376

  • Address

    Room 3661, No. 13, Lane 65, Huandong 1st Road, Fengjing Town, Jinshan District, Shanghai

Contact Now

How much is the 002810 SGE injection needle

NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Australian SGE injection needle 002810 10F-AG-0.63 is used as an automatic injection needle for gas chromatography

Product Details

SGE injection needle 002810 10F-AG-0.63It is a gas-phase pointed injection needle with a specification of 10ul. The SGE injection needle 002810 has a conical tip to reduce damage to the injection pad, making it an ideal choice for automatic injectors.


SGE injection needle 002810 10F-AG-0.63Introduction

Before use, be sure to check the syringe for cracks and burrs on the needle tip.

Press the plunger until the correct volume is reached. Bring back the plunger and wipe the needle tip with a cotton free tissue.

To ensure accuracy, the Z small injection volume of the syringe should not be less than 10% of its total capacity.

To remove bubbles, rotate the syringe vertically, attach one side of the barrel, remove the bubbles, and then discharge them from the syringe.

To eliminate carryover between samples, rinse the syringe with solvent 5-20 times and remember to discard the first 2-3 washes.

SGE injection needle ordering information:

volume Needle length (mm) label Outer diameter (mm) Needle tip type Order Number
Agilent 7670 replaceable needle
1μL 42 23 0.63 taper 000585
Agilent 7673、 7683 and 6850 ALS fixed needle - straight tube type
5μL* 42 26 0.47 taper 001800
5μL(M)* 42 23 0.63 taper 001810
10μL* 42 26 0.47 taper 002800
10μL(M) 42 23 0.63 taper 002810
10μL(M)airtight 42 23 0.63 taper 002812
Fixed needle - tapered cone
5μL* 42 23 – 26 0.63/0.47 Tapered cone shape 001821
10μL* 42 23 – 26 0.63/0.47 Tapered cone shape 002821
10 μ L airtight* 42 23 – 26 0.63/0.47 Tapered cone shape 002826
25 μ L airtight 42 23 – 26 0.63/0.47 Tapered cone shape 003668
50 μ L airtight 42 23 – 26 0.63/0.47 Tapered cone shape 004668
100 μ L airtight 42 23 – 26 0.63/0.47 Tapered cone shape 005668
Fixed Needle - SuperFleXTM Elastic Anti Folding Push Rod
10μL* 42 26 0.47 taper 002830
10μL* 42 23 0.63 taper 002835
Interchangeable needle - straight tube type
0.5μL# 42 26 0.47 taper 000400
0.5μL(M) # 42 23 0.63 taper 000410
1μL# 42 23 0.63 taper 000610
5μL 42 26 0.47 taper 001805
5μL(M) 42 23 0.63 taper 001815
10μL 42 26 0.47 taper 002805
10μL(M) 42 23 0.63 taper 002815
10 μ L airtight 42 26 0.47 taper 002817
10 μ L (M) airtight 42 23 0.64 taper 002818
25μL(M) 42 23 0.63 taper 003665
50μL 42 23 0.63 taper 004665
100μL 42 23 0.63 taper 005665
250μL 42 23 0.63 taper 006665
Swappable needle - tapered cone
0.5μL# 42 23 – 26 0.63/0.47 Tapered cone shape 000415
5μL 42 23 – 26 0.63/0.47 Tapered cone shape 001825
10μL 42 23 – 26 0.63/0.47 Tapered cone shape 002825
10 μ L (M) airtight 42 23 – 26 0.63/0.47 Tapered cone shape 002829
Swappable Needle - SuperFlexTMElastic anti folding push rod
10μL 42 26 0.47 taper 002844
10μL 42 23 0.63 taper 002845

(M) Suitable for Merlin Microseal sampler; *Multiple units can be ordered;
#Replace the needle; Replace the push rod item number; Replace the needle core without dead volume.


Cleaning of injection needle

Syringe cleaning agents typically rely on pollutants, with methanol and acetonitrile being commonly used cleaning solvents.

After cleaning the syringe, rinse it thoroughly.

Do not immerse the entire syringe in solvent, as this may damage the adhesive used to bond the syringe components.

Wipe the exterior clean with tissue. Disinfection methods:

-Autoclave: Remove the plunger from the barrel before high-pressure sterilization. Set the high-pressure vessel to the Z high temperature for removing needle syringes100℃, the high temperature of Z for fixed needle syringes is70℃. Before inserting the plunger into the barrel, allow the syringe to reach a certain temperature.

Gas: Use ethylene oxide.