Gas chromatograph for Baijiu analysisFeatures:
1. The instrument adopts a fully microcomputer control system, with a large screen LED display in both Chinese and English, providing rich and intuitive display content;
2. New digital design, highly integrated electronic circuit, excellent reliability, Chinese and English touch screen operation, convenient parameter setting and operation.
3. The column box structure is compact, the layout is reasonable, the temperature is uniform, and the intelligent dual channel rear door design makes the cooling speed faster (from 280 ℃ to 50 ℃ in just 8 minutes), the efficiency is higher, and it can be stably controlled at room temperature of 5 ℃, expanding the application range of the instrument.
4. The instrument can be equipped with two packed column gasification chambers and one capillary gasification chamber simultaneously, as well as two capillary gasification chambers simultaneously, and can be expanded from a single amplifier to a dual amplifier. According to different analysis applications, different combinations can be used to install up to three detectors simultaneously, such as FID, TCD, ECD detectors, etc. Can easily achieve the series and parallel operation of detectors. Truly achieving one machine with multiple uses.
5. The instrument can be equipped with capillary columns of different specifications (caliber 0.2-0.53MM), and its reasonable capillary injection system design (with split/non split injection, diaphragm blowing, and tail blowing systems) makes the out of column effect small and the column efficiency high; To achieve a peak shape with high chromatographic peak height, narrow half peak, and no tailing, thus obtaining accurate and good repeatability quantitative results.
6. The instrument adopts a modular design, making installation simple and maintenance more convenient; The new FID has a lower detection limit, making it easy to disassemble and clean the nozzle and ion collection electrode accuratelyThe fixed emitter installation structure ensures high consistency in the performance of each instrument.
7. The gas circuit adopts a dual design of first stabilizing the voltage and then stabilizing the current; Stable regulation mode, with high precision, high reliability, and convenient and intuitive flow regulation. Equipped with gas/gas leakage protection and prompt function, it can automatically cut off TCD bridge current and protect rhenium tungsten wire from damage.
8. Equipped with a six channel temperature control system, including column chamber, gasification chamber, detection chamber, converter, and external control events.
9. It has a nine order linear program heating function, which can meet the analysis of multi-component samples.
10. It has power-off protection, over temperature protection, and power on self-test functions.
Gas chromatograph for Baijiu analysistechnical indicators
1. Column box
Temperature control range: 6 ℃ to 400 ℃ at room temperature
Temperature control accuracy: within 200 ℃, the accuracy is ± 0.1 ℃
The accuracy is ± 0.2 ℃ within the range of 200 ℃ to 399 ℃
Program heating range: 6 ℃ to 400 ℃ at room temperature
Number of ascending orders: Nine orders
Cheng Sheng rate: 0.1 ℃ to 40 ℃, with increments of 0.1 ℃. At the beginning, the termination time range is 0-6000min, with increments of 1min
2.Baijiu chromatographsampler
Temperature control range: 6 ℃ to 400 ℃ at room temperature
3. Hydrogen flame ionization detector (FID)
Sensitivity: Mt ≤ 1 × 10-11G/s (n-hexadecane)
Noise: ≤ 5 × 10-14A
Drift: ≤ 1 × 10-13A/15min
Linear range: ≥ 106