E-mail
libin@wm-sensor.com
-
Phone
15111274459
-
Address
Room 1919, Building 4, Gaosheng Times Square, No. 798 Zhongyi 1st Road, Yuhua District
Hunan Weimei Electric Technology Co., Ltd
libin@wm-sensor.com
15111274459
Room 1919, Building 4, Gaosheng Times Square, No. 798 Zhongyi 1st Road, Yuhua District
Product description
Can replace Dynisco high-temperature melt pressure sensor with 1/2 threadCan you communicate with my companyNSeriesGThe series of intelligent digital pressure gauges and similar control instruments at home and abroad are used together to achieve pressure measurement and control; It has a built-in amplification circuit, and the amplified signal can also be directly inputPLCControl system, internal80%Calibration signal. This series of products is widely used in China, with the advantage of accurate and reliable pressure measurement, mainly used for pressure measurement in the extrusion industry such as plastic and rubber.
Product Features
● High cost-effectiveness
● All stainless steel packaging
● Easy to install
80% internal calibration
● Good stability and repeatability
Can replace Dynisco high-temperature melt pressure sensor with 1/2 threadApplication field
●Non woven fabric and synthetic fiber drawing equipment
Plastic and rubber manufacturing equipment
Medical, food processing, packaging and other equipment
Pressure monitoring of other high-temperature fluids
Technical Specifications
pressure range |
0~5MPa~200MPa | Overload pressure |
150% FS |
comprehensive accuracy |
± 1.0% FS (including linearity, repeatability, and hysteresis) | output signal |
4-20mA, 0-10V, 0-5V 2mV/V,3.33mV/V |
power supply voltage |
24(12~36)VDC 10VDC |
Internal self calibration |
80%FS ± 1% |
insulation resistance |
200MΩ @ 100VDC | Diaphragm temperature resistance |
Can withstand 400 ℃ |
Diaphragm material |
15-5PH coated stainless steel | Temperature model |
J, K, E, PT100 (PT124B-121T) |
electrical connection |
Five core aviation plugin | process connection |
1/2”-20UNF, M14 x 1.5, M18 x 1.5, M22 x 1.5, G3/4 |
Product dimensions

Installation precautions
1 . The installation of sensors: The sensor diaphragm is a relatively vulnerable part. Please do not remove its protective cap before installation, and pay attention to protecting the sensor diaphragm during installation.
The processing of installation holes should be carried out according to the technical requirements of the installation hole size diagram and size table, to avoid membrane scratches caused by non-standard installation holes that may affect the normal operation of the sensor.
2 . When dismantling and installing sensors, it is necessary to ensure that there are no metal or plastic objects left in the installation holes. Before cleaning the extruder, all sensors should be removed from the machine. The sensor can only be removed when the polymer is in a hot molten state. After removal, immediately wipe the sensor probe film with a soft cloth. At the same time, our company can provide specialized cleaning tools for installation holes to remove any remaining materials in the holes for easy installation next time.
3 . Before starting the equipment, sufficient heating and melting time should be ensured to ensure that all materials in the diaphragm area of the sensor are in a melted state before the extrusion machinery starts working.
4 . The probe part of the installation position sensor can withstand high temperatures, but the temperature resistance of the housing needs to be within80℃Therefore, during installation and use, it is important to pay attention to placing the installed sensor outside
The shell is fixed in a room temperature environment. Isolating the casing from high-temperature areas is beneficial for improving the measurement accuracy and service life of sensors.
5 . In the actual pressure control process, the impact of overload should be within the rated pressure. Although the sensor has a certain overload capacity, prolonged overload will affect the sensor's measurement
Measurement accuracy and service life.
6 . During the electrical connection process of the sensor, the signal output connection cable of the transmitter must be connected separately through a wiring duct to avoid interference on site.