Coal RF admittance level switch parameters

NegotiableUpdate on 05/09
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Radio frequency admittance level controller is currently a cutting-edge alternative product for international level controllers, which has been widely used in Europe, America, and Japan. Domestic users are also using it to replace old products. It can detect all materials without being affected by changes in parameters such as density, particle size, chemical composition, sedimentation viscosity, and conductivity. Widely used for controlling various materials such as liquids, powders, slurries, solids, etc.
Product Details

RF admittance level switch HL01-XXMZ01ZY31(Parameter: DC24V, 500mm) Threaded installation, widely used in industries such as metallurgy, power, coal, cement, and ports, is an important protective equipment for belt conveyors. Radio frequency admittance level switch, admittance level switch, and radio frequency admittance level meter are level control instruments designed based on absorbing the technology and functions of similar foreign products. All of its highly reliable sensors and stable circuit modules are made of imported components.shootThe frequency admittance level controller is currently a cutting-edge alternative product for international level controllers, which has been widely used in Europe, America, and Japan. Domestic users are also using it to replace old products. It can detect all materials without being affected by changes in parameters such as density, particle size, chemical composition, sedimentation viscosity, and conductivity. Widely used for controlling various materials such as liquids, powders, slurries, solids, etc.

Technical Specifications:

Working power supply: 220VAC50/60HZ

Power consumption:<3w<>

Contact capacity: AC380V 3A, 220V 5A

Material temperature: -20 ℃~+160 ℃

Measurement medium: Powder or granular material

Flexibility: Wear resistant rubber spring flexible shaft

Installation method: 3/4 pipe thread

Working principle of RF admittance level switch:

The RF admittance level controller is developed by our company based on the introduction and research of RF technology. It is an anti adhesion, more reliable, and widely applicable level controller: a high-frequency radio wave is applied to the probe. When the position of the material changes, the admittance value of the probe, container wall, and the measured material of the instrument changes accordingly. This change is detected by the circuit and converted into relevant signal outputs for remote control or alarm use. The circuit design of the instrument (utilizing the principle of equipotential) can eliminate the influence of material accumulation on the measurement circuit, thereby accurately reflecting the actual level of the material instead of adhering to the material accumulation on the probe.


Working principle of anti rotation level switch:

The anti rotation level switch uses a synchronous micro motor to drive the detection blades to rotate at a speed of one rotation per minute after deceleration. When the level of the tested material rises and the rotation of the blades is hindered, the detection mechanism generates rotational displacement around the main shaft. This displacement first activates a micro switch, emitting a material level signal. Subsequently, another micro switch is activated to cut off the power supply to the motor, causing it to stop running. As long as the material level remains unchanged, this state will continue indefinitely.

When the material level drops and the detection blade loses its obstruction, the detection mechanism relies on the spring tension to restore it to its original state. Firstly, a micro switch is activated to turn on the motor power and rotate it once. Then, another micro switch sends out a no material level signal. As long as there is no material blocking the rotation of the detection blade, this state will continue.

Key Features:

Strong universality: widely used in various occasions, including dust, particles, powders, liquids, viscous, conductive, and non-conductive materials.

Anti adhesion: The circuit design of * allows the measurement circuit to ignore the accumulation of materials on the probe and automatically calibrate.

Detached probe: The probe and controller can be separated without cable connection, making installation and removal easy and not affecting on-site work.

Powerful function: The output contact capacity is large, and there is an indicator light to display the working status. The impact of material fluctuations can be eliminated within 0-30 seconds.

Power outage protection: normally open or normally closed (switchable on-site)

Technical Specifications:

Power supply voltage: 220VAC/24VAC/24VDC

Power: 4W

Relay output: 5A/240VAC, two sets of normally open and normally closed contacts

Sensitivity: 0.3pf-750pf

Probe material: SUS304/SUS316/Teflon

Environmental temperature: -40-80

Delay time: adjustable from 0-30 seconds

Working temperature: -180-230 (ultra-high temperature up to 1000)

Connection thread: 1PT (special specifications can be customized)

Installation:

When selecting measuring points at the top of the warehouse, direct impact of materials on the level switch probe should be avoided. Therefore, the horizontal distance between the measuring point and the feeding port should be ≥ 1m. If there is a throwing angle during feeding, it should be avoided to directly face the throwing direction.

If applied to high material level measurement, in order to be able to measure the high point of the material level, the selection of measuring points should not be too far away from the feeding port.

3. Install flange pipes at the selected measuring points according to the installation diagram of the material level switch, and the flange plane should be horizontal.

4. Remove the material level switch, spiral the built-in flange upwards, connect the probe rod to the switch, and tighten the stop screw.

5. Insert the switch into the installation flange pipe and tighten the flange with 4 M 16 * 50 bolts.

6. Connect the wires according to the circuit diagram and turn on the power.

Typical applications:


Monitor various solid materials

For example: grains, milk powder, cement, lime, coal ash, processing materials, detergents, plastic pellets


Typical process:


Electric Power Metallurgy Cement Chemical Fertilizer Mining Coal Lime Food Feed


Measuring range


Full tank monitoring, intermediate quantity monitoring, empty tank monitoring




Medium temperature:


-40℃~+350℃


Ambient temperature


-40℃~+60℃


Container pressure:


-0.5..+10bar


Power supply:


230VAC、115VAC、48VAC、24VAC、24VDC、Multivoltage


Signal output:


SPDT,DPDT


Process connection:


Threaded: G 11/2 ", 11/4", 1 ", M32x1.5, M30x1.5, NPT 11/2", 1 1/4 ", 1"

Flange type: DN100 PN16, DN32 PN6, 2 ", 3", 4 "150lbs, 150x150


Process Connection&

Extended material:


Aluminum, stainless steel


Extension length:


70.300mm (top mounted), 70.150mm (side mounted, inclined mounted)


Measure blade:


Shoe shaped, rectangular, spring hinge shaped


Cable entrance:


M20x1.5(CE,ATEX),NPT1/2”(FM&CSA)


Shell:


Aluminum and epoxy resin coating


Protection level:


IP66 NEMA 4 Type 4


Optional:


Weather protection cover, installation components, cable entry, mobile card sleeve, enhanced sensitivity, signal light


characteristic:


Suitable for various solid materials, insensitive to material characteristics such as dust, conductivity, and viscosity,

*Maintenance free, adjustable sensitivity, rotatable casing, high resistance to mechanical impact