Capillary chromatographic column for supplying Baijiu

NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Baijiu has a history of thousands of years as an emotional carrier in people's daily life. Baijiu is closely related to people's life, and the analysis and detection of Baijiu is also very important. LZP-930 Baijiu capillary chromatographic column can well separate 15 components and 23 components of Baijiu specified in the national standard, which can meet the use requirements of the national standard.

Product Details

In recent years, the quality control of Baijiu has become increasingly strict. The application of gas chromatography in Baijiu production has become a powerful means to improve the quality of Baijiu. Due to the wide variety and complex components of Baijiu, gas phase analysis method plays a vital role in the identification of quality. Gas chromatograph analysis of BaijiuLZP930 Baijiu Capillary Column(Baijiu analysis column), detected by hydrogen flame ionization detector.

LZP-930Baijiu capillary columnSpecification: 30m × 0.32mm × 1.0 μ m

Due to the complex components of Baijiu mixed standard, the temperature programmed method was selected. For the separation of low boiling point components such as acetaldehyde and methanol, the selection of initial temperature is very important. After many tests, when the initial temperature is 50 ℃ and it is kept for 4 minutes, the separation of components with low boiling point is achieved. When the temperature rises to 230 ℃ at the rate of 5 ℃/min, other components in the Baijiu mixed standard are effectively separated.


LZP930 Baijiu Capillary ColumnAnalysis conditions:

柱温: 50℃(8min) to 170℃ at 10℃/min

Vaporization temperature: 220 ℃

Detection temperature: 230 ℃

SampleStandard sample of Baijiu23 components

Split ratio: 30:1

Column flow rate: 0.8ml/min


Column spectrum of Baijiu analysis:


图片1.png


─────────────────────────────────────

serial number retention time name peak area Peak separation degree Peak tailing factor

─────────────────────────────────────

1 5.044acetaldehyde22528 3.06 1.30

2 5.496methanol10776 4.14 1.99

3 8.660ethanol45959885 0.78 0.51

4 9.232isopropanol24213 5.15 1.77

5 10.259isobutyraldehyde11844 7.40 2.29

6 11.769n-propanol46677 1.85 1.88

7 12.090ethyl acetate80662 4.82 1.23

8 12.364diacetyl 2547 2.15 0.84

9 13.000sec-Butyl alcohol49086 7.21 1.57

10 14.262isobutanol68926 7.28 1.38

11 15.452Acetal30058 2.36 1.09

12 15.613n-butanol9739 1.99 1.20

13 16.137acetic acid54076 6.14 6.45

14 17.874Isopentanol76090 4.45 1.23

15 18.478Ethyl butyrate 30279 1.99 1.04

16 18.794propionic acid13067 1.09 2.79

17 19.016butyl acetate58447 6.99 1.01

18 20.348ethyl lactate203978 3.47 1.23

19 20.985丁酸22356 1.49 3.15

20 21.292Ethyl valerate103415 9.35 1.02

21 23.661valeric acid34587 2.35 4.63

22 24.212Ethyl hexanoate 288745 10.12 1.03

23 26.851hexanoic acid44286 2.39 4.97

24 27.749Ethyl heptanoate 90602 0.00 1.01

───────────────────────────────────