E-mail
476592670@qq.com
-
Phone
13375366215
-
Address
Weifang Oulong Technology Park
Shandong Leiente Intelligent Technology Co., Ltd
476592670@qq.com
13375366215
Weifang Oulong Technology Park
Portable oil particle size counterThe online oil particle counter is specifically designed for on-site online measurement and oil pollution level detection device. It has the advantages of small size, light weight, fast detection speed, high accuracy, and good repeatability, and can work under harsh conditions such as high temperature and high pressure. Suitable for all transparent solvents such as engine oil, gear oil, transformer oil (i.e. insulation oil), hydraulic oil, lubricating oil, synthetic oil, water-based (water-based hydraulic oil, water ethylene glycol, etc.), alcohols, ketones, etc. It can be widely used in power plants, aerospace, petrochemicals, transportation ports, steel metallurgy, automobile manufacturing and other fields.
Main Features
Using the principle of photoresist (light blocking) method, high-precision laser sensors are used, which have small size, high accuracy, and stable performance
Suitable for on-site online detection, it can monitor the particle pollution level in the oil system in real time
Built in data analysis system, capable of displaying real data of particle size in each channel and automatically determining sample grade
The standard model can directly withstand a pressure of 100 kilograms and can be equipped with a pressure reducing valve for online high-pressure measurement
L has volume flushing and duration flushing modes, making it convenient for users to use and maintain the equipment
lPortable oil particle size counterBuilt in particle pollution level standards such as ISO4406, NAS1638, SAE4059, GJB420A, GJB420B, Г OCT17216, GB/T14039, etc
Built in calibration function, can calibrate according to standards such as GB/T21540, ISO4402, ISO11171, GB/T18854, etc. One test can provide all built-in standard results
L can independently set all standards and any alarm level to achieve pollution or cleanliness detection
RS232 or RS485 interface, supporting standard Modbus protocol, can be connected to computers, upper computers, printers, PLC systems or other devices for data monitoring and processing
Large storage capacity, can be selected to be stored inside the instrument or on external storage devices
Durable exterior structure, suitable for complex working environments
The bottom in and top out mode is beneficial for minimizing the interference of online bubbles on test results
L can be tested continuously or the testing time interval can be set arbitrarily
Dual system in both Chinese and English, customers can freely switch, suitable for export
Touch screen or membrane button operation, can be freely switched, and the instrument interface can freely control the switch of the remote printer
Optional 4G/5G module, supporting remote data monitoring, historical data, and curve query on mobile phones or computers (optional)
Built in moisture and temperature sensor module, capable of simultaneously outputting four types of parameter information (optional)

technical indicators
Light source: semiconductor laser
Flow rate range: 5-500mL/min
Test sample viscosity: ≤ 650cSt
Online pressure detection: 0.1~10 Mpa
Particle size range: 1~600 μ m
Interface: USB interface, RS232 interface, RS485 interface
Data storage: Provides 1000 sets of data storage space and supports USB storage
Sensitivity: 1 μ m or 4 μ m (c)
Limit coincidence error: 40000 particles/ml
Counting volume: 1~999ml
Counting accuracy: ± 0.5 pollution level
Protection level: IP56
Temperature (optional): Collection range: 1-100 ℃; Measurement accuracy: 1 ℃
Water activity (optional): Collection range: 1~RH; Measurement accuracy: 1% RH
Water content (optional): Collection range: 1~360ppm; Measurement accuracy: 1ppm
Test interval: 1 second to 24 hours
Test sample temperature: 0~80 ℃
Working temperature: -20~60 ℃
Power supply: AC 220V ± 10%, 50/60Hz or DC12-40V
Weight: 1kg
Volume: 115 × 85 × 60mm