Which thermocouple manufacturer is good

NegotiableUpdate on 05/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

WRN thermocouples can directly measure the surface temperature of liquids, vapors, gases, and solids within the range of -200 ° C to 800 ° C in various production processes.

Product Details

WRN thermocoupleSpecializing in power station design, it can meet the temperature measurement needs of 300000, 600000 kW and other generator sets and auxiliary equipment. Directly measure the temperature of liquid, vapor, gas media, and solid surfaces within the range of -200 ° C to 800 ° C in various production processes.

WRN thermocoupleTechnical Specifications:

Product execution standards:
IEC584
Product Introduction
IEC751
IEC1515
JB/T18622-1997
JB/T8623-1997
GB/T16839-1997

Measurement range and tolerance

model Dividing number Tolerance level
I II
Allowable deviation Temperature measurement range ° C Allowable deviation Temperature measurement range ° C
WRN K ±1.5°C -40~+375 ±2.5 °C -40~+333
±0.004ltl 375~1000 ±0.0075 ltl 333~1200
WRM N ±1.5°C -40~+375 ±2.5°C -40~+333
±0.004 liters 375~1000 ±0.0075 ltl 333~1200
WRE E ±1.5°C -40~+375 ±1.5°C -40~+333
±0.004 liters 375~800 ±0.004 liters 333~900
WRF J ±1.5°C -40~+375 ±1.5°C -40~+333
±0.004 liters 375~750 ±0.004 liters 333~750
WRC T ±1.5°C -40~+125 ±1°C -40~+133
±0.004 liters 125~350 ±0.0075 ltl 133~350

Room temperature insulation resistance

The thermal resistance is tested at an ambient temperature of 15-35 ° C, relative humidity not exceeding 80%, and a test voltage of 10-100V (DC). The insulation resistance between the electrode and the outer sleeve is greater than 100M Ω.

The thermocouple is tested at an ambient temperature of 20 ± 15 ° C, relative humidity not exceeding 80%, and a test voltage of 500 ± 50V (DC). The insulation resistance between the electrode and the outer sleeve is greater than 1000 Ω m