Which is good for series resonance

NegotiableUpdate on 01/17
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Our company's BYXZ series frequency conversion series resonance test equipment is mainly used for the frequency conversion AC withstand voltage test of 10kV, 20KV, 35kV, 110kV cross-linked rubber power cables, 66kV, 110kV, 220kV combination electrical appliances (GIS), and power frequency AC withstand voltage test of hydraulic and thermal generators or power transformers. The basic principle is to use an adjustable (30-300Hz) series resonance test equipment to resonate with the capacitance of the test object to generate an AC test voltage.

Product Details

Complete set of equipment for frequency conversion series resonance testThe BYXZ series is mainly used for cross linked rubber power cables of 10kV, 20KV, 35kV, and 110kV, frequency conversion AC withstand voltage tests of 66kV, 110kV, and 220kV combination electrical appliances (GIS), and power frequency AC withstand voltage tests of hydraulic and thermal generators or power transformers. The basic principle is to use an adjustable (30-300Hz) series resonance test equipment to resonate with the capacitance of the test object to generate an AC test voltage. Due to the large capacitance of cables, traditional power frequency test transformers are bulky, bulky, and difficult to obtain on-site power sources with high currents. Therefore, series resonant AC withstand voltage test equipment is generally used. Its input power capacity can be significantly reduced, weight can be reduced, and it is easy to use and transport. In the initial stage, induction type series resonant devices (50Hz) were commonly used, but they have disadvantages such as poor automation and high noise. Therefore, nowadays, frequency conversion resonance is mostly used, which can achieve higher quality factor (Q value), and has advantages such as automatic tuning, multiple protections, noise reduction, flexible combination methods, and light weight per piece.

1Complete set of equipment for frequency conversion series resonance testCapacity selection of BYXZ series resonant device:

Test current: I=2 π fCU × 10-3 (A).

Frequency selection (HZ):

1. Generator -50HZ, take 50HZ.

2. Transformer -45~65Hz, take 50Hz.

3.GIS、 Switches and busbars -30~300Hz, take 45Hz.

4. Power cable: 30-300Hz, take 35Hz.

5. Voltage selection (KV): Determine the DA test voltage according to regulatory requirements.

6. Selection of capacitance (uf): determined based on the large capacitance of the test sample.

7. Large capacity of the device: P=UI × 1.25 (KVA).

2、 Main technical parameters:

Rated capacity: 270kVA.

Rated voltage: 45kV; 90kV; 135kV;270kV。

Rated current: 6A; 3A; 2A; 1A。

Measurement accuracy: The effective value of the system is at level 1.5.

Operating frequency: 30-300Hz.

Device output waveform: sine wave.

Quality factor: The device itself has a Q ≥ 30 (f=45Hz)

Waveform distortion rate: Output voltage waveform distortion rate ≤ 1%.

Input power supply: single-phase 220 or three-phase 380V voltage, frequency 50Hz.

Working time: Continuous 60 minutes allowed under rated load; Overvoltage 1.1 times for 1 minute.

Temperature rise: The temperature rise after continuous operation for 60 minutes under rated load is ≤ 65K.

Protection functions: overvoltage, overcurrent, zero start, system detuning (flashover) and other protection functions.

Environmental temperature: -20 ℃ -55 ℃.

Relative humidity: ≤ 90% RH.

Altitude: ≤ 3000 meters.

combination method

Subject of the test sample

Reactor selection(45kVA/45kV Section 6)

Incentive Transformer

Output terminal selection

Test voltage (kV)

10kV/300mm2 cable 3km

Use six reactors in parallel (with three reactors grounded)

4kV

≤22kV

35kV/300mm2 cable 1km

Use two reactors in series and three reactors in parallel

4kV

≤52kV

110kV/630mm2 cable 0.2km

Use three reactors in series and two groups in parallel

4kV

≤128kV

110kV/63000kVA main transformer with full insulation

Use four reactors in series

8kV

≤160kV

110kV and below voltage level GIS, switch bus busbar and other substation equipment

Use six reactors in series

16kV

≤265kV