1Six phase industrial control relay protection testing deviceKey Features:
1. Flexible combination of voltage and current output can achieve 6-phase voltage and 6-phase current, and can be freely combined to achieve conventional 4-phase voltage, 3-phase current type, 6-phase voltage type, 6-phase current type, and 12 phase output modes. It is compatible with various traditional testing methods, and can also be conveniently used for three-phase transformer differential testing, plant power fast switching, and backup automatic switching testing.
2. Operation method: The device can be directly connected to a laptop or desktop computer for convenient, fast, and stable performance.
3. New high fidelity linear power amplifier: The output end has always insisted on using high fidelity and high reliability modular linear power amplifiers, rather than switch type power amplifiers, which have better performance. It will not cause high or medium frequency interference on the test site, and ensures smooth waveform accuracy from high current to low current throughout the entire process.
4. High performance host: The output part is controlled by DSP, with fast operation speed, strong real-time digital signal processing capability, wide transmission frequency band, and high-resolution D/A conversion control. The output waveform has high accuracy, low distortion, and good linearity. The device adopts a large amount of technology and precision component materials, and has undergone specialized structural design, resulting in a small volume, light weight, comprehensive functions, easy portability, and can work immediately after startup. Flow testing is very convenient.
5. Powerful software functions: It can complete various large-scale complex verification tasks with high automation level, easily test and scan various protection settings, perform fault playback, store test data in real time, display vector graphics, print reports online, etc. 6-phase current can facilitate three-phase differential protection testing.
6. With independent DC power output: equipped with one 110V and 220V adjustable DC power output.
7. Complete interface: The device is equipped with a USB communication port, which can communicate with computers and other external devices.
8. Comprehensive self-protection function: The heat dissipation structure is designed reasonably, the hardware protection measures are reliable and complete, it has power soft start function, software self diagnosis of faults, and output locking function.
IISix phase industrial control relay protection testing deviceRelay test:
Relay protection type |
test project |
Suggested modules for testing |
Remarks |
signal relay |
Corresponding testing items |
DC test AC/DC test |
If an intermediate relay with mixed input of AC and DC is required, please test it in the "AC/DC Test" module Signal relays with rated current too low can be tested using the voltage circuit output of a tester |
time relay | |||
intermediate relay | |||
Reclosing relay | |||
Other DC voltage and current relays | |||
current relay |
Corresponding testing items |
Communication experiment |
Sequence component relays can be tested in the dedicated sequence component module of the "Communication Test" Reverse time relays can also be tested in the "I-t Characteristics" module |
Overvoltage (undervoltage) relay | |||
Sequential component relay | |||
Synchronization check (or phase comparison) relay | |||
Inverse time current relay | |||
Differential relay |
DC assisted magnetic properties |
Differential relay, differential harmonic, AC/DC test, harmonic test |
Please refer to the instruction manual for correct wiring during the experiment |
Harmonic braking characteristics | |||
Proportional braking characteristics |
Differential relay, AC test |
||
Power (direction) relay |
Corresponding testing items |
Power direction and impedance, AC test |
Before testing the power (direction) relay, the wiring type and approximate action boundary of the protection should be determined in advance |
Impedance relay | |||
synchronizing relay |
Corresponding testing items |
Simultaneous testing and communication testing |
The "synchronous test" module is fixed with the UA and UC of the tester as the system side and the voltage output to be parallel side, respectively |
Frequency relay |
Corresponding testing items |
Frequency and high-low cycle |
When selecting the "automatic frequency conversion" mode for single machine testing, it can test the frequency slip constant value |
3、 Microcomputer protection test:
Relay protection type |
test project |
Suggested modules for testing |
Remarks |
|
|
line road guarantee protect |
Multiple overcurrent segments |
Corresponding testing items |
Communication experiment |
As long as the method is appropriate, the "communication test" module can be used for most relay and microcomputer protection tests, and this module should be emphasized for learning |
Over (under) voltage | ||||
Sequential component voltage and current | ||||
Frequency device | ||||
Power direction protection | ||||
Recloser and switching faults |
Corresponding testing items |
Comprehensive testing of whole set test, line protection, status sequence, and 6-35kV line protection |
Require testing for synchronization and no voltage, using Ux as the output voltage for the parallel side. The tester uses Ua instead of Ux for testing |
|
Distance and zero sequence |
Distance and zero sequence constant value verification |
Distance and zero sequence, line protection, whole group test, AC test |
Both "distance and zero sequence" and "line protection" can automatically test multiple segments, various fault types, and various phase distances and zero sequence settings at once |
|
impedance characteristics |
impedance characteristics |
|||
Distance of power frequency variation |
Fixed value verification |
Distance and zero sequence, line protection |
The fault current should be set sufficiently large, such as 10~15A (when it is a 5A CT) |
|
Composite voltage lockout (direction) overcurrent |
Overcurrent, low voltage, negative sequence voltage, sensitive angle, etc |
Communication test, comprehensive testing of 6-35kV line protection |
Some protected "low voltage" and "negative sequence voltage" are input from different terminals, and the wiring needs to be replaced during testing |
|
Low cycle and low voltage load shedding device |
Corresponding testing items |
Comprehensive testing of frequency and high/low cycle, 6-35kV line protection |
If all other conditions are met but the device cannot operate, please confirm whether the device still needs to input current and switch contacts simultaneously |
|
|
send change group guarantee protect |
differential protection |
Proportional braking characteristics |
Differential protection, differential setting, AC test |
Generator differential protection, when tested with "differential protection", can be regarded as a transformer protection with a wiring type of Y/Y and a balance coefficient of 1 on both the high and low voltage sides Differential protection "focuses on curve characteristic search, while the" differential setting "module focuses on differential setting testing. The combination of the two can comprehensively test differential protection |
Harmonic braking characteristics |
Differential protection, differential setting, harmonic test |
|||
Demagnetization protection |
Corresponding testing items |
Communication experiment |
During the experiment, attention should be paid to the angle between the output voltage and current |
|
Excitation protection | ||||
Composite voltage lockout (direction) overcurrent (backup) |
Corresponding testing items |
Please refer to the "Line Protection" section in the previous text |
Please refer to the "Line Protection" section in the previous text |
|
its it guarantee protect |
Automatic quasi synchronous device |
Corresponding testing items |
Simultaneous experiment |
When conducting automatic adjustment tests, each input must be wired according to the instructions |
Busbar differential protection |
Corresponding testing items |
Communication experiment |
Please refer to the description of BP-2B and RCS-915 in the "Nanrui Partial Protection" section |