TORAY Toray Compact Zirconia Oxygen Concentrator RF-400-01 Ikedaya Industrial Advantage Supply, and provide quotation pictures
TORAY Compact Zirconia Oxygen Concentration Meter RF-400-01 from Japan
TORAY Compact Zirconia Oxygen Concentration Meter RF-400-01 from Japan
The zirconia oxygen concentration meter RF-400-01 is a product developed for nitrogen reflow soldering equipment, utilizing our years of accumulated manufacturing technology for oxygen concentration meters in the electronics industry. It is also compatible with high concentrations (dirty gases).
Equipped with our compact zirconia sensor, it can perform stable and high-precision measurements for a long time, and is also equipped with an oxygen sensor protection mechanism, achieving durability beyond traditional products.
This is a good oxygen concentration meter that combines simple operation and compact design, and can be integrated into various devices including nitrogen reflux equipment.
Product Features
Adopting a new type of particle filter
It uses a new type of particle filter that can react with oil and color it, making it easy to determine its expected lifespan. The filter can be replaced without removing the oxygen meter from the instrument.
Using special filters
It improves the durability of the oxygen sensor and can handle various deteriorated substances.
Wide power supply
Compatible with AC100V to 240V power supply.
Convenient measurement range
The measurement range is 0-10000ppm, commonly used in nitrogen reflow soldering equipment (0-1% range can also be selected).
Compatible with standards
Safety: CE, UKCA...EN61010-1
EMC:CE…EN61326-1
Environmental regulations
RoHS指令... EN63000
Optional support
The filters we provide help prevent sensor degradation and ensure accurate measurement of indicated and measured values.
① Activated carbon filter: a filter that adsorbs trace amounts of organic matter and small amounts of combustible gases. In addition to preventing impurities from entering the sensor, it can also prevent the measured oxygen from burning inside the sensor, thereby achieving accurate readings.
② Cotton filter: a filter that prevents dust and solid substances from entering. Prevent foreign objects from entering the oxygen concentration meter or adhering to the sensor to prevent deterioration of the oxygen concentration meter.
③ Silicon filter: a filter that adsorbs gases containing silicon. By preventing silicon containing gases from entering the sensor, sensor degradation can be prevented and accurate measurements can be achieved.
Product Specifications
Specifications
| shape |
Desktop/panel mounted type |
| display mode |
4-digit display (concentration display) |
| measurement range |
10ppm~100vol%O2 0- 1/10/100/1000/10000ppm (1)/10/ |
| measurement range |
10 -20 ~10 -0 atm *Cannot guarantee 0-10ppm range and below *You can choose between a range of 0-10000ppm or a range of 0-1% |
| Sampling method |
Built in pump continuous suction type |
| gas supply volume |
1000-2000mL/min |
| Sensor gas quantity |
60 ± 10 milliliters per minute |
| Gas connection port |
INLET (sample gas inlet) Rc1/4 BYPASSOUT (bypass outlet) Rc1/4 OUTLET (sample gas outlet) Rc1/4 |
| Comparing gases |
atmosphere |
| a large amount of |
About 6.5 kilograms |
| paint color |
Munsell N3 matte paint (black) |
feature
| repetitiveness |
When 1% (10000ppm) ≤ measured gas ≤ 100%: ± 1% FS When 10ppm ≤ measured gas ≤ 1% (10000ppm): ± 2% FS (Cannot guarantee display range below 0-10ppm) |
| Air point stability |
± 1% FS/24 hours |
engineering specifications
| Measurement value output |
External output: 4-20mA, RS-232C |
| Concentration alarm output |
LED display (upper and lower limits) Contact output: 2a output separately Contact capacity: AC30V/DC30V, 1A |
| Self diagnostic function |
Preheating abnormality, thermocouple abnormality, internal temperature abnormality CPU abnormality, furnace temperature abnormality Asymmetric potential abnormality, sensor resistance value abnormality, AIR point calibration abnormality SPAN point calibration abnormality |
| Sample gas conditions |
Must be free of flammable components, halogens, silica, corrosive components, and water droplets Pressure: 29.4 kPa or lower Pressure flow rate: 1000 to 2000 mL/min Temperature: 0 to 50 ° C Humidity: Dew point lower than ambient temperature |
| warm-up time |
Within 6 minutes |
| power supply |
Voltage: AC100V to 240V Required power capacity: 200VA Power consumption: 50W |
| Installation requirements |
Installation location: indoor, non explosion proof area Environmental temperature: 0 to 50 ° C Environmental humidity: 20 to 85% RH (non condensing) Does not contain flammable components, halogens, silica or corrosive components |
| option |
Activated carbon filter Cotton filter cartridge Silicon filter cartridge |