WZP type thermistorDetailed Introduction
WZP type thermistor
Thermal Resistor Coreis used forPrefabricated thermistorOne of the temperature measuring components of the product, it can not only serve asthermal resistorThe component can be used in conjunction with the thermistor protection tube, or it can be used separatelydisplay instrument、Recording instrumentWait for the secondary instrument to measure and display the temperature of liquids, gases, and solid surfaces during each production process. This product has the advantages of small size, high accuracy, good linearity, fast thermal response time, and long-term stability, making it one of the most ideal temperature measuring components.
WZP type thermistorMain technical parameters:
1. Specification diameter: 3, 4, 5, 6, 8
2. Accuracy level: * B level
3. Index number: Pt100 Cu50
4. Temperature measurement range: -200 ° C to 600 ° C
5. Thermal response time: < 30s
6. Measurement end form: Single: Two wire system, Three wire system, Four wire system, Double support, Four wire system, Double support, Six wire system
7. Product execution standards
JB/T 8623-1997 JB/T 8622-1997
8. Temperature measurement and tolerance
Thermal resistance category |
Temperature measurement range |
graduation mark |
Allowable deviation △ t ℃ |
WZP type thermistor |
-200~600 |
Pt100 |
Grade B (-200~600 ℃ tolerance ± (0.30+0.005 | t |) |
*(-200~550 ℃) allowable deviation ± (0.15+0.002 | t |) | |||
WZC type copper resistor |
-50~150 |
Cu50 |
B-level tolerance ± (0.3+6.0 × 10-3t) |
Note:'t 'in the formula represents the measured temperature value of the temperature sensing element. | |||
Model and Specifications
| WZ□ | Thermal resistance standard type |
||||||||||
|
mark |
Types of thermal resistors |
|||||||||
C |
Copper thermistor |
||||||||||
P |
platinum resistance thermometer |
||||||||||
|
mark |
Measurement end form |
|||||||||
1 |
Single count (unmarked) with a diameter of 3 to 8 |
||||||||||
2 |
Double branch (not applicable to copper thermistors) with a diameter of 5 to 8 |
||||||||||
|
mark |
Connection type |
|||||||||
-0 |
No installation and fixing method |
||||||||||
|
mark |
Connection type |
|||||||||
1 |
With porcelain plate |
||||||||||
9 |
Lead out type |
||||||||||
|
mark |
accuracy class |
|||||||||
A |
* |
||||||||||
B |
Grade B |
||||||||||
|
mark |
|
|||||||||
2 |
Two line system - suitable for single tube |
||||||||||
3 |
Three wire system - suitable for single tube |
||||||||||
4 |
Four wire system - suitable for single or double support |
||||||||||
6 |
Six wire system - suitable for double support |
||||||||||
Mark S- |
Sensor diameter |
||||||||||
3 |
F3 |
||||||||||
4 |
F4 |
||||||||||
5 |
F5 |
||||||||||
6 |
F6 |
||||||||||
8 |
F8 |
||||||||||
|
mark |
sensor length |
|||||||||
X pole length |
L= mm |
|
|||||||||
|
+Lead length |
l= mm |
|||||||||