Overview

The LW8558AD laboratory penicillin bottle cleaning machine can be used for cleaning, disinfecting, and drying conventional glassware in the laboratory. This model of cleaning machine can be used in preparation laboratories, pharmaceutical and food laboratories, water quality and environmental analysis laboratories, microbiology laboratories, petrochemical laboratories, paper and pulp industry laboratories, etc.

Product Details

Overview of LW8558AD Laboratory Penicillin Bottle Cleaning Machine Equipment

The LW8558AD laboratory penicillin bottle cleaning machine provides a new user experience for cleaning, disinfecting, and drying laboratory glassware. It not only reduces the daily workload of laboratory personnel and lowers the occupational risks associated with cleaning vessels, but also ensures standardized, reproducible, and verifiable cleaning quality, making it a device for cleaning vessels in small laboratories.

实验室西林瓶清洗机


LW8558AD Laboratory Penicillin Bottle Cleaning MachineApplicable Industries

This equipment can be used in preparation laboratories, pharmaceutical and food laboratories, water quality and environmental analysis laboratories, microbiology laboratories, petrochemical laboratories, paper and pulp industry laboratories, etc.

Cleaning vessels can clean laboratory vessels of different materials (glass, ceramic, plastic, and metal), shapes (test tubes, culture dishes, volumetric flasks, conical flasks, measuring cylinders, etc.), capacities, and sizes (2 ml, 50 ml, 1000 ml). Generally speaking, this includes glass, heat-resistant plastics, stainless steel, and coated metal items such as containers (beakers, conical flasks, Erlenmeyer flasks, bottles, test tubes, separatory funnels, etc.), measuring containers (volumetric flasks, measuring cylinders, pipettes, etc.), dishes (Petri dishes, mortars, surface dishes, etc.), and small parts (plugs, scrapers, stirring rods, etc.).

Laboratory penicillin bottle cleaning machinefunction

Cleaning: Removing dirt from cleaning items to a level that can be further processed and used.

Disinfection: Reduce the amount of active microorganisms on items to make them suitable for further processing and use. According to the heating and disinfection parameters of EN ISO 15883-1, continuous heating at 80 ° C (+5 ° C, -0 ° C) for 10 minutes or at 90 ° C (+5 ° C, -0 ° C) for 5 minutes is necessary to suppress the activity of hepatitis B virus.

Drying: The residual moisture on the vessel can be evaporated by hot air

Data export: A tool used to connect to a printer or computer, which can download all information related to cleaning and disinfection programs, providing data support for cleaning verification.

Specifications:

working conditions

1.1 Working voltage: 380V, 50/60Hz

1.2 Cold water source: meets the national standards for urban tap water, with a water pressure of 1.0-5.0kg/cm2 and a water temperature of 5-40 ℃.

1.3 Pure water source: meets the Class III/I water standard of GB6682-2008 for water used in Chinese analytical laboratories

实验室西林瓶清洗机


Equipment structure

2.1 Loading Door: Front loading and equipped with a pull-down door

2.2 Structure: Adopting a double-layer detachable insulation and sound insulation shell design, reducing heat loss

2.3 Material: 304 grade stainless steel shell, 316L grade stainless steel liner, with * anti-corrosion function.

2.4 Water inlet method: The top coupling system of the basket frame can effectively utilize water, and the basket frame has a wide adaptability to glassware.

2.5 Inner cavity: Surface polished to a roughness of<0.6m ra=''>

2.6 Spray system: A certain number of rotating spray systems should be equipped to ensure the coverage of the cleaning process, and their design should also avoid

Prevent the occurrence of particles during the cleaning stage.

2.8 Equipment size: Inner cavity size: L * D * H: 535/510/500mm, outer shell size: L * D * H: 990 * 700 * 1300mm

control system

3.1 Adopting Mitsubishi PLC control system from Japan, 7-inch large LCD display screen, program controlled cleaning, with 10 standards

Cleaning program, customers can set multiple custom cleaning programs according to their needs;

3.2 Interlocking device: Electronic door lock for safe operation, which can be activated through buttons, programs, and manual modes

Open;

3.3 Operation permissions: operator, administrator, system engineer; Each level has corresponding customizable permissions to enable

Use screen data or modify parameters.

3.4 Alarm device: The control system should alarm for equipment abnormalities and deviations, and can achieve automatic sound alarm,

Display alarm information on the display screen and automatically print records, and the alarm information can be displayed on the operation interface.

drying system

4.1 Air filtration: High efficiency filter/HEPA is used, with a filtration speed greater than 99.992%

4.2 Fan: Air flow rate of 60m3/hour

4.3 Hot charging device: 1.5KW

4.4 Steam Condenser: Convert water vapor into liquid and discharge it through a dual steam condenser to avoid increasing room humidity

Protect electronic components from damage.

Cleaning agent distribution

5.1 Distribution pump DOS 10/30 for liquid acidic additives (1 unit)

5.2 Distribution pump DOS 60/30 for liquid cleaning agents (1 unit)

5.3 Drawer for storing 2 x 10 liter containers