E-mail
wangjh@dianjiangtech.com
-
Phone
19901636028
-
Address
Building 42, Fortune Xingyuan, Lane 188, Maoting Road, Chedun Town, Songjiang District, Shanghai
DianDian (Shanghai) Technology Co., Ltd
wangjh@dianjiangtech.com
19901636028
Building 42, Fortune Xingyuan, Lane 188, Maoting Road, Chedun Town, Songjiang District, Shanghai
SF-GStem flow (liquid flow) measurement systemDirectly measuring plant stem flow to determine plant water consumption (transpiration). If other sensors are added, plant stem flow can be measured under environmental factors such as air temperature, humidity, PAR, soil temperature, humidity, etc.
Principle:The SF-G stem flow sensor is a probe based instrument invented by French inventor GRANIER for measuring daytime stem flow. During work, two probes are inserted into different parts of the tree trunk. The upper probe is heated by a constant flow, creating a temperature difference between the two probes. When the stem flow rises, it takes away heat, and the temperature difference between the two probes decreases. There is a functional relationship between the temperature difference and the stem flow. Calculate stem flow by measuring temperature difference. Different stem flows generate different temperature differences, and sensors sense the small voltage generated thereby, providing data for stem flow calculation To calculate daytime stem flow, a stem flow value of zero must be set.
SF-GStem flow (liquid flow) measurement systemfeature:
·Suitable for trees with a diameter greater than 2 centimeters;
·For different bark thicknesses, probes of different lengths can be selected and customized;
·Sensors can be reused;
·Unable to measure nighttime liquid flow;
Technical Specifications:
probe body |
SF-G |
Needle length/heating wire length |
18/10mm,33/20mm,43/20mm,63/20mm |
compose |
2-pin type, probe diameter of 1.5 millimeters |
cable length |
5m, Can be extended up to 20m |
Suitable for tree diameter |
Diameter>2 centimeters |
power consumption |
0.2 watts+/-5%, 84 milliamps, DC |
Need data acquisition channel |
1 differential channel |
output |
0 to 1000 microvolts |
power supply |
CCS, One CCS can supply 1 to 3 sensors, consuming 1 watt (12V x84mA) |
Install the attachment |
1 radiation shield, 4 aluminum tubes, 1 silicone tube, 1 roll of adhesive tape |
data acquisition |
CR1000 |
Large sampling frequency |
100Hz |
Simulated channel |
8 differential channels (16 single ended channels) |
pulse channel |
2 of them |
controlled output |
8 of them |
Excitation channel |
3 voltage channels |
Other ports |
4 SDI-12 or 4 RS232 (shared with 8 control output interfaces) |
Data communication port |
1 CS I/O; 1 RS-232; 1 parallel peripheral device |
Signal input range |
±5000mV |
A/D conversion accuracy |
13 bit analog-to-digital conversion |
measurement resolution |
0.33 µV |
measurement accuracy |
± (reading * 0.06%+offset), 0~40 ℃ |
Built in storage space |
4M |
power supply voltage |
9.6~16VDC |
power consumption |
Sleep mode: 0.6mA, 1Hz Acquisition frequency: 4.2mA |
size |
23.9×10.2×6.1cm |
Operating Temperature |
-25~50℃; -55~85 ℃ (Extended) |
Origin: Germany