Quotation for Plant Stem Flow Measurement System

NegotiableUpdate on 01/18
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The SF-G stem flow (liquid flow) measurement system directly measures plant stem flow to determine plant water consumption (transpiration). If other sensors are added, plant stem flow can be measured under environmental factors such as air temperature, humidity, PAR, soil temperature, humidity, etc.
Product Details

SF-GStem flow (liquid flow) measurement systemDirectly measuring plant stem flow to determine plant water consumption (transpiration). If other sensors are added, plant stem flow can be measured under environmental factors such as air temperature, humidity, PAR, soil temperature, humidity, etc.

Principle:The SF-G stem flow sensor is a probe based instrument invented by French inventor GRANIER for measuring daytime stem flow. During work, two probes are inserted into different parts of the tree trunk. The upper probe is heated by a constant flow, creating a temperature difference between the two probes. When the stem flow rises, it takes away heat, and the temperature difference between the two probes decreases. There is a functional relationship between the temperature difference and the stem flow. Calculate stem flow by measuring temperature difference. Different stem flows generate different temperature differences, and sensors sense the small voltage generated thereby, providing data for stem flow calculation To calculate daytime stem flow, a stem flow value of zero must be set.

SF-GStem flow (liquid flow) measurement systemfeature

·Suitable for trees with a diameter greater than 2 centimeters;

·For different bark thicknesses, probes of different lengths can be selected and customized;

·Sensors can be reused;

·Unable to measure nighttime liquid flow;

Technical Specifications

probe body

SF-G

Needle length/heating wire length

18/10mm,33/20mm,43/20mm,63/20mm

compose

2-pin type, probe diameter of 1.5 millimeters

cable length

5m, Can be extended up to 20m

Suitable for tree diameter

Diameter>2 centimeters

power consumption

0.2 watts+/-5%, 84 milliamps, DC

Need data acquisition channel

1 differential channel

output

0 to 1000 microvolts

power supply

CCS, One CCS can supply 1 to 3 sensors, consuming 1 watt (12V x84mA)

Install the attachment

1 radiation shield, 4 aluminum tubes, 1 silicone tube, 1 roll of adhesive tape

data acquisition

CR1000

Large sampling frequency

100Hz

Simulated channel

8 differential channels (16 single ended channels)

pulse channel

2 of them

controlled output

8 of them

Excitation channel

3 voltage channels

Other ports

4 SDI-12 or 4 RS232 (shared with 8 control output interfaces)

Data communication port

1 CS I/O; 1 RS-232; 1 parallel peripheral device

Signal input range

±5000mV

A/D conversion accuracy

13 bit analog-to-digital conversion

measurement resolution

0.33 µV

measurement accuracy

± (reading * 0.06%+offset), 0~40 ℃

Built in storage space

4M

power supply voltage

9.6~16VDC

power consumption

Sleep mode: 0.6mA, 1Hz Acquisition frequency: 4.2mA

size

23.9×10.2×6.1cm

Operating Temperature

-25~50℃; -55~85 ℃ (Extended)

Origin: Germany