Quotation for Low Voltage Loss Mass Flow Controller

NegotiableUpdate on 02/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The full-scale pressure loss Z can reach up to 0.06 PSID, and low-pressure loss applications are no longer a problem. Alicat's low-pressure loss mass flow controller (Whisper series) is Alicat's solution for low-pressure applications, which can measure and control any flow rate from 0.5 SCCM to 500 SLPM at full scale, with a pressure loss Z as low as 0.06 PSID. We can accurately measure and control the mass flow rate of both challenging low-pressure and expensive gases.
Product Details

1AlicatLow pressure loss mass flow controllerProduct description

When the price of the gas being tested is high or the total pressure of the system is low, the problem of pressure loss has to be addressed directly.AlicatofWhisperSeries quality flowmeter&The mass flow controller is designed specifically for low pressure loss applications. adoptAlicatDesign of laminar flow and bubble flowWhisperSeries performance, low pressure loss up to0.06PSID.

IIAlicatLow pressure loss mass flow controllerProduct advantages

Alicat Newly launchedWhisperSeries Low Pressure Loss Mass Flow Meter&Mass flow controller(digital/Simulated type)Designed for applications with extremely low inlet pressure.

Easy to operate

WhisperSeries Mass Flow Meter&The mass flow controller is an independent device with a multifunctional digital display screen. Users can operate the flow meter or controller through panel buttons, including adjusting the set value andPIDCircuit parameters, etc., do not require connection to a computer or any other complex programming software.

Accurate measurement

WhisperSeries Mass Flow Meter&The measurement and control accuracy of the mass flow controller can reach ±(0.8% Rdg + 0.2% F.S.).

cost-effective

Alicat ofWhisperThe series has reduced the pressure loss of flow measurement and control to a certain extent The industry is at a low level. Reducing pressure loss means more gas enters the system instead of staying in the measurement&In the control equipment.WhisperThe series is specifically designed for applications where the system pressure is extremely low and the introduction of any equipment can cause gas flow stagnation. andAlicat Standard quality flowmeter(Mseries)&Mass flow controller(MCseries)Same, except for mass flow rate,Whisper The series can also measure volume flow rate, pressure, and temperature simultaneously, so you don't need to purchase and install other equipment separately. Use accumulator(TOT)The function can display the total amount of gas flowing through, which is an effective method for monitoring the entire application process and reducing gas waste.WhisperSeries quality flowmeter&The mass flow controller itself consumes fewer electrodes, thereby further reducing the operating costs of the system.

performance

WhisperSeries quality flowmeter&The mass flow controller can measure and control from0.5SCCMto500SLPMAny flow rate at full range, equipped with multiple analog signal outputs andRS-232Digital signal output.WhisperThe series of mass flow meters also have portable models(MWBseries)Using a regular piece9Powered by a battery, it becomes a low voltage loss second-class standard flow calibration device.

responsive

10The typical response time in milliseconds meansWhisperThe response speed of the series quality flowmeter is at least twice as fast as your blink, in fact, at the moment you blink,WhisperThe valve opening of the series quality flow controller has been adjusted1000Next time.

IIIAlicatLow pressure loss mass flow controllerProduct performance

  • Multi functional digital display screen

  • Display multiple measurement parameters: mass flow rate, volume flow rate, temperature, and pressure

  • Ultra low voltage loss

  • No warm-up needed

  • adjustablePIDalgorithm (Only used for mass flow controllers)

  • built-in30Gas options available

  • 200:1 Adjustable range ratio

  • RS-232Multi point digital input/output

  • Measurable and controllable from0.5SCCMto500SLPMAny flow rate at full range

Optional performance

  • high precision

  • accumulator

  • ProfiBUSDigital signal output

  • RS-485Digital signal output

  • RS-485Digital signal input

  • TFTBacklit color display screen

  • Remote display screen

  • remoteTFTBacklit color display screen

  • Acrylic insulation coating

  • EPDMseal

  • NeSSIontology

  • oxygen cleaning

  • Remote electronic packaging for high-temperature environments

  • SAEjoint

  • VCRTheVCO joint

  • Stainless steel valve (Only used for mass flow controllers)

High flow low pressure loss valve (Only used for mass flow controllers)