TORAY Toray RF-400-01 Zirconia Oxygen Concentration Meter from Japan is a brand new boutique!
New boutique TORAY zirconia oxygen concentration meter from Japan!
| shape | Desktop/panel mounted type |
|---|---|
| display mode | 4-digit display (concentration display) |
| measurement range |
10ppm~100vol%O2 0- 1/10/100/1000/10000ppm (1)/10/ |
| measurement range |
10 -20~10-0atm *Cannot guarantee 0-10ppm range and below *You can choose between a range of 0-10000ppm or a range of 0-1% |
| Sampling method | Built in pump continuous suction type |
| gas supply volume | 1000-2000mL/min |
| Sensor gas quantity | 60 ± 10 milliliters per minute |
| Gas connection port |
INLET (sample gas inlet) Rc1/4 BYPASSOUT (bypass outlet) Rc1/4 OUTLET (sample gas outlet) Rc1/4 |
| Comparing gases | atmosphere |
| a large amount of | About 6.5 kilograms |
| paint color | Munsell N3 matte paint (black) |
| repetitiveness |
1% (10000ppm) ≤ When measuring gas: ± 1% FS When 10ppm ≤ measured gas ≤ 1% (10000ppm): ± 2% FS (Cannot guarantee display range below 0-10ppm) |
|---|---|
| Air point stability | ± 1% FS/24 hours |
| Measurement value output | External output: 4-20mA, RS-232C |
|---|---|
| Concentration alarm output |
LED display (upper and lower limits) Contact output: 2a output separately Contact capacity: AC30V/DC30V, 1A |
| Self diagnostic function |
Preheating abnormality, thermocouple abnormality, internal temperature abnormality CPU abnormality, furnace temperature abnormality Asymmetric potential abnormality, sensor resistance value abnormality, AIR point calibration abnormality SPAN point calibration abnormality |
| Sample gas conditions |
Must be free of flammable components, halogens, silica, corrosive components, and water droplets Pressure: 29.4 kPa or lower Pressure flow rate: 1000 to 2000 mL/min Temperature: 0 to 50 ° C Humidity: Dew point lower than ambient temperature |
| warm-up time | Within 6 minutes |
| power supply |
Voltage: AC100V to 240V Required power capacity: 200VA Power consumption: 50W |
| Installation requirements |
Installation location: indoor, non explosion proof area Environmental temperature: 0 to 50 ° C Environmental humidity: 20 to 85% RH (non condensing) Does not contain flammable components, halogens, silica or corrosive components |
| option |
Activated carbon filter Cotton filter cartridge Silicon filter cartridge |