E-mail
18500490921@126.com
-
Phone
18500490921
-
Address
3101 Jiangxi Building, No.16 Shizhuang Road, Xinhua District, Shijiazhuang City, Hebei Province
Hebei Zhurong Environmental Technology Co., Ltd
18500490921@126.com
18500490921
3101 Jiangxi Building, No.16 Shizhuang Road, Xinhua District, Shijiazhuang City, Hebei Province
Multi functional smoke analyzer for multi scenario application procurementFour year warranty, touch screen display function, and equipped with computer data management software and smartphone applications for more in-depth combustion efficiency analysis.
Intelligent gas sensors can be replaced on-site to further improve measurement performance.
1,configuration2 or3 Group gas sensor: O2, COandLow NO/ Low NOx
2,Pre calibrated intelligent sensors that can be replaced on-site
3,Can be set to stop air pump protectionCOSensor poisoning
4,Can be movedApp/Computer software generates reports,automatic/Manually record and analyze data
5,compact and lightweight,Self weight only350 gram
6,High definition color touch screen
Multi functional smoke analyzer for multi scenario application procurementProduct Features
ŸCan be set to stop air pump protectionCOSensor poisoning
ŸOne click activation/Turn off the air pump
Ÿcomputer software,Can be connected wirelessly& USBconnect
ŸGraphical display
ŸPersonalized settings analysis display parameters
ŸMaintenance Reminder,Sensor lifespan&Calibration cycle prompt
ŸSqueezing pressure&Differential pressure measurement
Ÿ CO2parameter calculation
ŸenvironmentCOsafety monitoring
ŸCalculation of combustion efficiency and excess air coefficient
ŸHost anti slip rubber protective cover
Ÿ 4Annual warranty service
ŸadjustableO2Reference base
Dimensions
Technical Specifications
parameter |
sensor |
range |
resolution |
accuracy(1) |
T90response time |
O2 |
electrochemistry |
0 ~ 25% |
0.01 % |
± 0.2% vol |
< 30 s |
CO |
electrochemistry |
0 ~ 8,000 ppm |
1 ppm |
± 8 ppm ( 0 ~ 159 ppm) ± 5%measured value( 160 ~ 2,000 ppm) ± 10%measured value( 2,001 ~ 8,000 ppm) |
< 40 s |
CO2 |
calculated value |
0 ~ 99.9% |
0.1 % |
- |
- |
Low NO |
electrochemistry |
0 ~ 300 ppm |
0.1 ppm |
± 1.5 ppm (0.0 ~ 29.9 ppm) ± 5%measured value (30.0 ~ 300.0 ppm) |
< 40 s |
Low NOx |
calculated value |
0 ~ 450 ppm |
0.1 ppm |
- |
|
|
flue gas temperature (host) |
TcK |
-20 ~ +1,250 °C |
0.1 °C |
± 2 °Cor ± 0.5%measured value(2) |
- |
ambient temperature |
NTCor TcK |
-20 ~ +120 °C |
0.1 °C |
±2 °C |
- |
Temperature difference value |
calculated value |
0 ~ 1,250 °C |
0.1 °C |
- |
- |
|
pressure (differential pressure/Squeezing pressure) |
semiconductor |
-200 ~ +200 mbar |
0.01 mbar |
± 1%measured value ±0.03 mbar |
- |
Excess air coefficient |
calculated value |
0 ~ 999% |
1 % |
- |
- |
Low heat combustion efficiency |
calculated value |
099% (Overall efficiencyHHV (3) |
0.1 % |
- |
- |
High thermal combustion efficiency |
calculated value |
0 ~ 125% (Net efficiencyLHV (4) |
0.1 % |
- |
- |
flue gas velocity |
calculated value |
0 ~ 99 m/s |
0.1 m/s |
- |
- |
Order number |
suit model |
Suit Details |
27509 |
Si-CA 130 Kit 2BS |
2 Group gas sensor(O2andCO), 300mmProbe temperature resistance to +800 °C, 3mcable,Host anti slip rubber protective cover,Condensed water tank,charger, USBdata cable,quick start guide,Factory calibration certificate and portable bag |
27517 |
Si-CA 130 Kit 3LowBS |
3 Group gas sensor(O2, COand Low NO/Low NOx), 300mmProbe temperature resistance to +800 °C, 3mcable,Host anti slip rubber protective cover,Condensed water tank,charger, USBdata cable,quick start guide,Factory calibration certificate and portable bag |