KY-9000SA fully automatic sulfur contentMeasuring instrument (156 bits)
Main features of the instrument:
*1. The instrument adopts popular USB port communication, standard 24 bit data acquisition, and detects signals less than 1 microvolt.
*2. Data can be stored, accessed, printed at will, and relevant problems can be solved based on on-site data files.
*3. The main components of the instrument are made of * devices, which have better overall performance than similar domestic instruments and can replace imported products.
*4. The high voltage of the photomultiplier tube (PMT) can be adjusted arbitrarily, and the calibration of the standard curve can be done using single point or multi-point calibration, making it easy to operate.
*5. The instrument has * sensitivity, linearity, and analysis resultsreliable
*6. The software can run on all current operating systems and has strong adaptability. The instrument software has powerful functions.
KY-9000SA fully automatic sulfur content analyzer (156 bits)Instrument execution standard:
*SH/T 0689 Determination of Total Sulfur Content in Light Hydrocarbons, Engine Fuels, and Other Oil Products by UV Fluorescence Method
*GBT 34100-2017 Determination of Total Sulfur Content in Light Hydrocarbons, Engine Fuels, and Other Oil Products by UV Fluorescence Method
*GB/T 35582 sulfur and nitrogen element analyzer
*ASTMD5453 Standard Test Method for Total Sulfur Content of Light Hydrocarbons, Spark Ignition Engine Fuel, Diesel Engine Fuel, and Engine Oil by Ultraviolet Fluorescence Method
*ASTM D6667 Test Method for Total Volatile Sulfur Content in Gaseous Hydrocarbons and Liquefied Petroleum Gas by Ultraviolet Fluorescence Measurement
*ASTM D7183 Standard Test Method for Total Sulfur Content in Aromatic Hydrocarbons and Related Compounds by Ultraviolet Fluorescence Method
*ISO 17198 Determination of total sulfur content using ultraviolet fluorescence method for dimethyl ether (DME) fuel
*DB51/T 1689 Determination of Total Sulfur Content in Liquefied Natural Gas (LNG) by UV Fluorescence Method
*GB/T 11060.8 Determination of Sulfides in Natural Gas Part 8: Determination of Total Sulfur Content by UV Fluorescence Method
Main technical parameters:
*1.Sample type: Liquid
*2.Measurement method: UV fluorescence method (S)
*3.Sample tray:156 positions
*4. Waste liquid bottle position: 1
*5. Solvent bottle position: 2
*6. Injection volume: 0.1ul~250ul
*7.Measurement range: 01mg/L~20000mg/L
*8.Detection limit: 01mg/L
*9.Repeatability error: 1.0mg/l, ± 0.2 mg/l
1.0mg/l
100mg/l
*10.Gas source requirement: high-purity oxygen: 99.99%The above high-purity argon gas: 99.99%Above
*11. Temperature control range: room temperature~1100℃
*12.Temperature control accuracy: ±2℃