Welcome Customer !

Membership

Help

Chengde Feirui Automation Equipment Co., Ltd
Custom manufacturer

Main Products:

ag-mach>Products
Product Categories

Chengde Feirui Automation Equipment Co., Ltd

  • E-mail

    13653344774@163.com

  • Phone

    17832040885

  • Address

    High tech Zone, Chengde City, Hebei Province

Contact Now

Kaifeng electromagnetic flowmeter quotation

NegotiableUpdate on 01/18
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The FR200 series intelligent electromagnetic flowmeter has a display function in both Chinese and English, with two options of low-frequency excitation and high-frequency excitation (for slurry measurement). It also has the advantages of high accuracy, low power consumption, and easy maintenance. This product is widely used in metallurgy, chemical industry, urban construction, environmental protection, food, medicine and other fields to measure the volume flow rate of conductive liquids such as raw water, sewage, slurry, acidic and alkaline solutions.

Product Details

Overview

LDB200 series intelligentElectromagnetic FlowmeterEquipped with both Chinese and English display functions, low-frequency excitation and high-frequency excitation (for slurry measurement) are available for selection. It also has the advantages of high accuracy, low power consumption, and easy maintenance. This product is widely used in metallurgy, chemical industry, urban construction, environmental protection, food, medicine and other fields to measure the volume flow rate of conductive liquids such as raw water, sewage, slurry, acidic and alkaline solutions.

feature

Low frequency three value rectangular wave constant current excitation, not affected by power frequency and various stray interferences on site, works very stably and reliably.

The new technology of adopting non-uniform magnetic field and special magnetic circuit structure greatly reduces the volume and weight, and has the characteristics of small and lightweight.

Equipped with isolated RS485 communication function, isolated pulse output, microprocessor can automatically detect and reset air traffic control.

On site, parameters such as range, medium density, and flow unit can be modified online according to the actual needs of users.

There are no movable parts or obstruction components, and there is almost no additional pressure loss during measurement.

The measurement results are independent of physical parameters such as flow velocity distribution, liquid pressure, temperature, density, viscosity, etc.

Easy to use, simply connect the power supply after installation and it can be used. Instantaneous and cumulative quantities are directly displayed in Chinese on the upper and lower rows of the LCD screen.

Technical Specifications

Nominal diameter series DN (mm): DN5-DN600

Accuracy level: 0.5 level; Level 1.0

Temperature of the tested medium: Rubber lining: -20 to+60 ℃; High temperature rubber lining: -20 to+90 ℃;

Polytetrafluoroethylene (PTFE) lining: -25 to+140 ℃; Po lining: -30 to+105 ℃

Rated working pressure: DN10~DN65: 2.5Mpa

DN80~DN150: 1.6MPa

DN200~DN600: 1.0Mpa

Please specify other special pressures (such as 6.4MPa) when ordering

Flow measurement range: The flow measurement range corresponds to a flow velocity range of 0.05-10m/s

Conductivity range: The conductivity of the measured fluid shall not be less than 20us/cm

Output signal and load resistance: 4-20mADC, 0-750 Ω; 0-1000HZ, duty cycle 50%

Communication signal (RS-485): Up to 256 interfaces of the same type can be connected and isolated on the electrical device.

Cable length: The total length is less than 2Km.

Baud rate: 300-9600bps

Electrode materials: Molybdenum containing stainless steel, titanium (Ti), tantalum (Ta), Hastelloy (HC), platinum (Pt) or other electrodes with special requirements

Protection level: Submersible type: IP68; Other: IP65

Power supply: 220VAC ± 10%, 50HZ ± 5%; 24VDC

Length of straight pipe section: upstream ≥ 5DN, downstream ≥ 2DN

Connection method: The flowmeter and piping are connected by flanges, and the flange connection size should comply with the provisions of GB9119-88

High pressure type: butt welded connection between the high-pressure flange and piping provided by the supplier

Explosion proof mark: mdIIBT4

Environmental temperature: -25 ℃ to+45 ℃

Relative humidity: 5% to 95%

Total power consumption: less than 20W