Welcome Customer !

Membership

Help

Chengde Feirui Automation Equipment Co., Ltd
Custom manufacturer

Main Products:

ag-mach>Products
Product Categories

Chengde Feirui Automation Equipment Co., Ltd

  • E-mail

    13653344774@163.com

  • Phone

    17832040885

  • Address

    High tech Zone, Chengde City, Hebei Province

Contact Now

How much is the PTFE rotor flowmeter

NegotiableUpdate on 01/18
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Chengde Feirui metal tube rotor flowmeter is suitable for measuring the flow rate of liquids, gases, and vapors in closed pipelines, and is widely used in measurement and self-control systems in industries such as petrochemicals, chemical engineering, fertilizers, metallurgy, power, food, pharmaceuticals, and papermaking.

Product Details

1Chengde Feirui - Metal tube rotor flowmeterOverview

DSF1The series metal tube float flowmeter is suitable for measuring the flow rate of liquids, gases, and vapors in closed pipelines. Composed of a measuring tube and an indicator, using the principle of variable area measurement, the measured medium flows through the measuring tube from bottom to top. Relative to a certain flow rate value of the measured medium, the magnetic float will correspond to a position in the measuring tube. This position is transmitted to the indicator system through magnetic coupling, and the corresponding flow rate value is read out by the dial and pointer. When the transmitter is installed, it can output 4~20mAStandard current signal, digital communication signal, or switch contact signal. In addition to the structural forms applicable to the inflow and outflow directions of the medium, there are also special structural forms applicable to other flow directions.

DSF1The series of metal tube float flowmeters have been widely used in measurement and self-control systems in industries such as petrochemicals, chemical engineering, fertilizers, metallurgy, power, food, pharmaceuticals, and papermaking for many years due to their excellent craftsmanship, complete functions, stable performance, and safe and reliable quality.

IIChengde Feirui - Metal tube rotor flowmeterfeature

1Measurement tube

Durable all metal structure design that can meet all pressure rating requirements;

You can choose stainless steel, Hastelloy, titaniumInconelTheMonel, liningPTFEVarious materials;

Adopting a special structural design to meet high-temperature usage requirements;

In addition to the bottom in and top out vertical installation structure, it can meet various installation needs;

For crystalline media or occasions that require insulation, jacket type can be chosen.

2Indicator

Optional cast aluminum304 or316 Stainless steel indicator housing;

Coaxial magnetic system, powerful pointer damping function, makes instrument operation safer, more stable and reliable;

Modular design allows for quick addition or replacement of transmitters to instruments on-site;

The transmitter hasLCD(backlight)The function of displaying instantaneous flow and cumulative flow on site;

Optional two-wire system 420mATransmitter module;

optional Dry contact andrelayWaiting for multiple alarm switches to meet different working conditions and integrated system requirements;;

optionalModbus RTUorHARTWaiting for multiple communication protocols;

There are low-power battery powered options available;

Explosion proof:Exd(Gas)/Dust)

IIITechnical Specifications

instrument model

DSF10

flow range

water 10----200000l/h

air 0.07 to 4000m3/h(20, 1.013bar)

turndown ratio

101Standard type 201(Special type)

precision

Standard accuracy:1.5%High precision1%

connection method

flange connection

mark accurateHG/T20592(DN15DN200)

special 殊:DIN2512(DN15DN200)

ANSI(1/2"-8)

National standards, Japanese standards, etc. are based on user needs

threaded connection DIN11851Or according to user needs

work pressure

DN15DN50 PN4.0Mpa(Special type)25Mpa

DN80DN100 PN1.6Mpa(Special type)16Mpa

Clamp pressure rating:1.6Mpa

temperature range

medium temperature

40 to+220(standard form)

20 to+90(PTFEtype)

40 t o+400(high-temperature type)

ambient temperature

40 to+60

medium viscosity

DN15: ≤5mPa.s(S15.1S15.3)30mPa.s(S15.4S15.9)

DN25: ≤250mPa.s

DN50DN150:≤300mPa. s

LCD (Liquid Crystal Display)

Instantaneous flow display numerical range050000

Accumulated traffic display value range099999999

output

Standard signal:two-wire system420mA

pulse signal:minimum interval50ms

alarm signal:Collector open circuit, MAX100mA@30VDCInternal impedance100W

power supply

standard form:24VDC(10.8VDC36VDC

communicative:220VAC(85265VAC)

battery type: 3.6@4AHNickel-metal hydride battery

electrical interface

M20×1.51/2NPT

overall height

standard form250mm(Except for other installation methods)

Protection level

IP65

Explosion-proof rating

ExdbIICT6 Gb