The RFS GEMS adjustable flow switch in the United States is based on the working principle of the rotor, and it will not indicate a flow state in the absence of flow. Once an action point is set, RotorFlow will indicate a "no flow" state regardless of whether the rotor stops working for any reason.
|
RFS US GEMS Adjustable Flow SwitchIntroduction:
Combine visual flow state with electronic switch action Concise and adjustable switch point calibration; When the set point is reached, the LED signal is displayed
RotorFlow switchRaise the reliability of your equipment to a new standard. Based on the working principle of the rotor, it will not indicate a flow state in the absence of flow. Once an action point is set, RotorFlow will indicate a "no flow" state regardless of whether the rotor stops working for any reason.
RFS US GEMS Adjustable Flow SwitchTypical ApplicationsProtect valuable electronic devices from damage caused by coolant flow interruption
Semiconductor production equipment
laser
Medical equipment
X-rays and other high-energy tubes
Mechanized welding equipment
|
|
RFS US GEMS Adjustable Flow Switchperformance parameters welding materials Shell made of copper, stainless steel or polypropylene (hydrolytically stable, glass tempered) Ceramic rotor shaft Nylon mixture for rotor Lens polysulfone O-ring Viton (alloy body); Rubber (polypropylene) Low flow adapter glass reinforced polypropylene The highest work pressure Copper or stainless steel shell 200 PSIG@70 ℉ Polypropylene shell 100 PSIG@70 ℉,40 PSI MAX@180 ℉ Zui high working temperature Copper or stainless steel shell -20~212 ℉ (-29 ℃~100 ℃) Polypropylene shell -20~180 ℉ (-29 ℃~82 ℃) The ambient temperature for the electrical part is 150 ℉ (65 ℃) Zui high viscosity 200 SSU Input voltage 24 VDC or 110 VAC Relay contact (SPDT) 1Amp, 24VDC resistive; 0.3Amp,110 VAC Repeatability 2% MAX Set point accuracy (factory setting) ± 5% Set point deviation 15% MAX Electrical connection 20AWG PVC sheath, 24 '' cable, color code: Red=VAC/VDC, Black=Ground White=normally open contact, brown=normally closed contact Green=Public Connection Point
|
RFS US GEMS Adjustable Flow Switchstandard
|
Set point calibration using LED signal (F6RFS type)
After installing and powering on the pipeline, complete the following steps to calibrate the flow value at the switch action point. The only tool required is a straight screwdriver.
1. Adjust the flow rate on the pipeline to within the range of the switch action. 2. Insert a screwdriver into the opening behind the casing and into the adjustment screw of the potentiometer. 3. If the LED does not light up, slowly rotate the screwdriver clockwise until the LED lights up. 4. If the LED is on, slowly rotate the screwdriver clockwise until the LED goes out. Then slowly rotate the screwdriver counterclockwise until the LED lights up
|