Hash 1720E Low Range Online Turbidity MeterLXV525.KTO014CN
1720EApplication Industry
The online turbidity meter can be applied to monitor the turbidity of pre filtration, post filtration, sedimentation, and effluent water in water plants; Monitoring of water quality in municipal pipeline networks; Industrial process water quality monitoring, circulating cooling water, activated carbon filter effluent, membrane filtration effluent, etc.

Hash 1720E Low Range Online Turbidity MeterLXV525.KTO014CN
technical indicators | ||
range |
0.0001~ 9.9999; 10.000~ 99.999NTU; Automatically select range |
|
Accuracy: |
0 When the reading is around 40NTU, take the larger of ± 2% or ± 0.02 of the reading |
|
40 ± 5% of the reading at around 100NTU | ||
Resolution: |
0~ 9.9999NTU: 0.0001NTU; |
|
10.000~ 99.999NTU: 0.001NTU | ||
Reproducibility: |
Better than ± 1.0% or ± 0.002 of the reading, whichever is greater |
|
Response time: |
Step response, initial response time of about 1 minute and 15 seconds |
|
Signal average: |
6Users can choose between 30, 60, and 90 seconds; The default value for users is around 30 seconds |
|
Sample flow rate: |
200~750mL/min |
|
Operating Temperature |
For single sensor systems, the temperature ranges from 0 to 50 ℃, while for dual sensor systems, the temperature ranges from 0 to 40 ℃ |
|
Sample temperature: |
0 ~ 50℃ |
|
Simulated output |
0/4~20mA optional. Programmable within the range of 0-100NTU |
|
relay: |
3 SPDT only, 230VAC, 5A; Setable point alarm |
|
Power requirements: |
100~230VAC,50/60Hz, Automatic selection; 40VA |
|
Inlet pipeline: |
1/4' NPTInternal thread, 1/4 'compression fitting (provided) |
|
Drainage pipeline: |
1/2' NPTInternal thread, 1/2 'hose (provided) |
|
Digital Communication: |
MODBUS/RS485,MODBUS/RS232,LonWorksProtocol, Profibus (optional) |
|
Standard method: |
Standard Method 2130B, USEPA 180.1, HACH Method 8195 |
|
shell |
NEMA-4X/IP66controller |
|
Size: |
Turbidity meter: 25.4 × 30.5 × 40.6cm |
|
Ordering Guide | ||
Whole machine order | ||
2976800CN |
1720E turbidity meter with sc200 controller, probe cable length of 2 meters, 20 NTU STABLCAL standard solution |
|
2978100CN |
1720E turbidity meter with SC200 controller (single channel, 220V), probe cable length of 2 meters, STABLCAL standard solution of 20NTU |
|
2976900CN |
1720E turbidity meter with SC200 controller (dual channel, 24V), probe length of 2 meters, 20 NTU STABLCAL standard solution |
|
2978200CN |
1720E turbidity meter with SC200 controller (single channel, 24V), probe length of 2 meters, 20NTU STABLCAL standard solution. For other communication output order numbers, please refer to the SC200 ordering instructions |
|
Single turbidity probe | ||
60101-01 |
1720ETurbidity meter probe, probe cable length of 2 meters |
|
|
|
||
1720EOptional Accessories
5796000 25ft. (7.6M) extension cable
4630800 Power cord (230VAC) with waterproof plug. (Note: The power cord must be ordered separately)
5225000 20NTU, ICE-PIC verification module
5221500 1NTU,ICE-PICVerification Module
2660153-CN 20.0NTU,1L,STABLCALVerification and calibration standard solution
2659853-CN 1.0NTU,1L,STABLCALVerification and calibration standard solution
4415600-CN FORMAZINCalibration toolkit
246149-CN FormazinStandard solution, 4000NTU, 500ml
4415300 Calibration bucket, 1L (order separately)