Welcome Customer !

Membership

Help

Shanghai Shangshi Era Experimental Equipment Co., Ltd
Custom manufacturer

Main Products:

ag-mach>Products
Product Categories

Shanghai Shangshi Era Experimental Equipment Co., Ltd

  • E-mail

    zhouhuibing@ctel.net.cn

  • Phone

    13917524241

  • Address

    No. 111 Wencai Road, Shanghai

Contact Now

Which is a good cold and hot shock test chamber

NegotiableUpdate on 01/18
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The cold and hot shock test chamber is a testing equipment used in the metal, plastic, rubber, electronics and other material industries to test material structures or composite materials. It can withstand continuous environmental changes of high and extremely low temperatures in an instant, and detect chemical changes or physical damage caused by thermal expansion and contraction of the sample in the shortest possible time.

Product Details

thermal shock chamberIt is a testing equipment used in the metal, plastic, rubber, electronics and other material industries to test material structures or composite materials. It can withstand continuous environmental changes of high and extremely low temperatures in an instant, and detect chemical changes or physical damage caused by thermal expansion and contraction of the sample in the shortest possible time.

Product Model

SS-LRCJ2-400

SS-LRCJ3-225

structural approach

Two box impact (basket style)

Three boxes of impact

Studio size D * W * H

600*600*620mm

500*600*750mm

Basket size D * W * H

400*400*400mm

/

Nominal internal volume

64L

225L

Dimensions D * W * H

2350*1370*1950mm

1700*2000*2200mm

Main technical parameters

(1) Temperature shock range: -55 ℃ to+85 ℃;

(2) Temperature fluctuation: ≤± 1.0 ℃;

(3) Low temperature pre cooling:+25 ℃ to -55 ℃ ≤ 45 minutes;

(4) High temperature preheating: rise from+25 ℃ to+150 ℃ for ≤ 25 minutes;

(5) Basket transfer time: ≤ 10s;

(6) Temperature recovery time: ≤ 5 minutes.

(1) Temperature shock range: -55 ℃ to+150 ℃;

(2) Temperature fluctuation: ≤± 1.0 ℃;

(3) Low temperature pre cooling:+25 ℃ to -60 ℃ ≤ 50min;

(4) High temperature preheating: rise from+25 ℃ to+150 ℃ for ≤ 25 minutes;

(5) Wind door switching time: 5 seconds;

(6) Temperature recovery time: ≤ 5 minutes.

meet the standard

GB/T 2423.1-2008 Environmental testing for electrical and electronic products - Part 2: Test methods - Test A: Low temperature;

GB/T 2423.2-2008 Environmental testing for electrical and electronic products - Part 2: Test methods - Test B: High temperature;

GB/T 2423.22-2012 Environmental Testing Part 2: Test Methods Test N: Temperature Variation;

GB/T 10592-2023 Technical Conditions for High and Low Temperature Test Chambers;

If the above standards and specifications are replaced by new standards and specifications, the new standards and specifications shall be implemented.






















Note:thermal shock chamberNon universal standard sizes or other special temperature requirements can be consulted for customization.