E-mail
perit@139.com
-
Phone
13816937484
-
Address
Room 9011, Building B, Lane 519, Macau Road, Putuo District, Shanghai
Shanghai Xudun Electronic Technology Co., Ltd
perit@139.com
13816937484
Room 9011, Building B, Lane 519, Macau Road, Putuo District, Shanghai
+GF+Signet pH/ORP Electrode Product Introduction
Diagnostic Function of GF Magnet 2751 pH/ORP Intelligent Sensor、
The performance and ease of use have been greatly improved,
At the same time, it ensuresmaximumThe process and data integrity.
The 2751 solution does not require on-site calibration and can help reduce system downtime,
And reduce the cost of correction. The automatic performance check function also reduces time-consuming maintenance and calibration.
For greater flexibility and * functionality, please pair the 2724-2726 or 2734-2736 series with the 2751 Smart
Sensor electronics paired with 9900 transmitter, 9950 dual channel transmitter, or 0486 Profibus hub
Use it. Other features include electrode health monitoring through glass impedance measurement, glass breakage detection, and reference impedance measurement
Testing and diagnosis. Convenient remote calibration eliminates the hassle of on-site calibration.
Using digital (S ³ L) signal output, connect six 2724-2726 or 2734-2736 electrodes to an 8900 multiparameter
On the controller, use 6 2751 pH/ORP sensor signal amplifiers
Using digital (S ³ L) signal output, pair two 2724-2726 or 2734-2736 electrodes with two 2751 pH/ORP
The sensor signal amplifier is connected to a 9950 dual channel transmitter.
The electrodes 2724-2726 are recommended for general use applications.
2734-2736 electrodes are recommended for harsh applications.
2734-2736 electrode, utilizing * reference technology to extend electrode lifespan in almost all applications.
+GF+Signet pH/ORP Electrode Product Introduction
Ordering Information
2724-2726 and 2734-2736 pH/ORP electrodes * * used in conjunction with amplifier 2751
Manufacturer Part Number Order Number Description
3-2724-00 159 001 545 electrode, pH, Flat glass, PT1000, 3/4 in. NPT thread**
3-2724-01 159 001 546 electrode, pH, Flat glass, PT1000, ISO7/1 R3/4 thread*
3-2724-10 159 001 547 electrode, pH, Flat glass, 3K Balco, 3/4 in. NPT thread
3-2724-11 159 001 548 electrode, pH, Flat glass, 3K Balco, ISO7/1 R 3/4 thread
3-2724-HF-10 159 001 771 electrode, PH, Hydrofluoric acid resistant, flat glass, 3K Balco, 3/4 in. NPT thread
3-2724-HF-11 159 001 772 electrode, pH, Hydrofluoric acid resistant, flat glass, 3K Balco, ISO7/1 R 3/4 thread
3-2726-00 159 001 553 electrode, pH, Light bulb type glass, PT1000, 3/4 in. NPT thread**
3-2726-01 159 001 554 electrode, pH, Light bulb type glass, PT1000, ISO7/1 R 3/4 thread**
3-2726-10 159 001 555 electrode, pH, Light bulb glass, 3K Balco, 3/4 in. NPT thread
3-2726-11 159 001 556 electrode, pH, Light bulb type glass, 3K Balco, ISO7/1 R 3/4 thread
3-2726-HF-00 159 001 549 electrode, pH, Hydrofluoric acid resistant, bulb type glass, PT1000, 3/4 in. NPT thread**
3-2726-HF-01 159 001 550 electrode, pH, Hydrofluoric acid resistant, bulb type glass, PT1000, ISO7/1 R 3/4 thread**