E-mail
2942709300@qq.com
-
Phone
13631787342,15899943952
-
Address
Antai Building, No.4 Hongbao Road, Dongcheng Street, Dongguan City
Dongguan Haoen Testing Instrument Co., Ltd
2942709300@qq.com
13631787342,15899943952
Antai Building, No.4 Hongbao Road, Dongcheng Street, Dongguan City
1Electromagnetic three-axis vibration test benchPurpose:
Widely applicable to industries such as national defense, aviation, communication, electronics, automotive, home appliances, etc. This type of equipment is used to detect early faults, simulate actual working conditions for assessment, and conduct structural strength tests.
IIElectromagnetic three-axis vibration test benchMain functions:
1. Vibration function:
① Vertical ② Horizontal ③ Front and Back
④ Continuous movements (vertical horizontal, vertical front back, horizontal vertical, horizontal front back, front back vertical, front back horizontal)
⑤ Random vibration
⑥ Vertical+horizontal+forward and backward simultaneous vibration.
2. FM function: Set the frequency arbitrarily within the frequency range.
3. Sweep frequency function: (up frequency/down frequency/time range) can be set arbitrarily.
4. Programmable function: 1~15 segments can be adjusted arbitrarily, and each segment can be set arbitrarily (frequency/time) and cycled.
5. Frequency doubling function: Adjust 1-15 segments arbitrarily to increase the multiplier by ① low to high frequency, ② high to low frequency, ③ low to high and then to low frequency/recyclable.
6. Logarithmic function: 3 modes of logarithmic/cyclic adjustment: ① down to up frequency ② up to down frequency ③ down to up and then down frequency.
3、 Main technical parameters:
frequency range |
vertical |
level |
Vertical+Horizontal+Front Back |
50HZ (fixed frequency) |
HE-LD-Y-50 |
HE-LD-X-50 |
HE-LD-YX-50 |
1~600HZ (frequency conversion) |
HE-LD-Y |
HE-LD-X |
HE-LD-YX |
1~3000HZ |
HE-LD-Y-3 |
HE-LD-X-3 |
HE-LD-YX-3 |
1~5000HZ |
HE-LD-Y-5 |
HE-LD-X-5 |
HE-LD-YX-5 |
1. Workbench size (L * W): 50cm * 50cm
2. Vibration waveform: sine wave; half-sine
3. Frequency resolution accuracy: 0.01Hz
4. Scanning resolution accuracy: 0.01Hz
5. Amplitude (p-p): 0-5mm
6. Acceleration: 10g (acceleration, frequency, amplitude are interdependent)
7. Test load: 60KG
8. Time control: Any time can be set (in seconds)
9. Precision: The frequency can be displayed up to 0.01Hz, with a precision of 0.1Hz
10. Power supply voltage (V): 220 ± 20%
11. If you need to see the amplitude, waveform, acceleration, and accurate acceleration numbers, you need to purchase a separate measuring instrument.
12. All data shall be subject to no-load testing
13. Calculation formula: 1G=0.002xF ² xD 1g=9.8m/s ²
F: Frequency (in Hz) D: Amplitude G: Acceleration