Schneider contactor distributor LC1D115006Q5C is a 3-level contactor from the TeSysD series, suitable for various control type motor systems with ambient temperatures below 60 ° C.
Product Details

Schneider contactor agent

LC1D115006Q5C is a 3-level contactor from the TeSysD series, suitable for various control type motor systems with ambient temperatures below 60 ° C. It operates 3600 times per hour with a standard control coil providing a voltage of 380V 50Hz and a working altitude of 3000m. The product passes through and meets IP2X protection level on the front, preventing direct finger contact. It uses a ring terminal wiring method.


Size chart

Schneider contactor agentSpecifications

Product Series TeSys
Product Type contactor
Product short name LC1D
Application fields of contactors Applied to non inductive or micro inductive loads, resistance furnaces
Applied to AC loads with a power factor greater than or equal to 0.95
Usage category AC-1
AC-3
polar number 3P
Rated working voltage [Ue] Power circuit:<=300='' v='' dc=''>Power circuit:<=1000='' v='' ac='' 25... 400='' hz=''>
Rated working current [Ie] 200 A 60 ° C) on...<=440='' v='' ac='' ac-1=''>115 A 60 ° C) on...<=440='' v='' ac='' ac-3=''>

Supplementary information
Electric motor power (kW) 30 kW on... 220/240 V AC 50/60 Hz (AC-3)
55 kW on... 380/400 V AC 50/60 Hz (AC-3)
59 kW on... 415/440 V AC 50/60 Hz (AC-3)
75 kW on... 500 V AC 50/60 Hz (AC-3)
80 kW on... 660/690 V AC 50/60 Hz (AC-3)
75 kW on... 1000 V AC 50/60 Hz (AC-3)
Type of circuit contact 3 NO
protective cover none
Auxiliary contact type exclude
Rated insulation voltage [Ui] Power circuit: 1000 V in accordance with IEC 60947-4-1
Rated impulse withstand voltage [Uimp] 8 kV complies with IEC 60947
Overvoltage category III
Agreed heating current [Ith] 200 A on...<60>
Fuses used in conjunction with relays 250 A gG on...<=690='' v=''>200 A gG on...<=690='' v=''>
Control circuit characteristics AC on... 50/60 Hz
Surge suppression module No built-in surge suppression module
Average impedance 0.6 m? - Ith 200 A 50 Hz suitable power circuit
operating frequency 2400 times/hour on...<60>
(~50Hz suction) Power consumption (VA) 280…350 VA 50 Hz 0.8 20 °C)
280…350 VA 60 Hz 0.8 20 °C)
(~50Hz hold) Power consumption (VA) 2…18 VA 50 Hz 0.3 20 °C)
2…18 VA 60 Hz 0.3 20 °C)
Wiring ability Control Circuit: Bolt Tightening 2 1... 2.5 mm2 Cable Selection: Flexible Wire with Cable Terminal
Control Circuit: Bolt Tightening 1... 2.5 mm2 Cable Selection: Flexible Wire with Cable Terminal
Power Circuit: Bus Terminal Cable Selection: Hardwire Bus Cross Section: 5 x 25 mm
Power circuit: What is the outer diameter of the 10... 120 mm2 terminal block? 25 mm cable selection: flexible wire without wire terminal
Power circuit: What is the outer diameter of the 10... 50 mm2 terminal block? 25 mm cable selection: flexible wire without wire terminal
Power circuit: What is the outer diameter of the 10... 120 mm2 terminal block? 25 mm cable selection: flexible wire with wire terminal
Power circuit: What is the outer diameter of the 10... 50 mm2 terminal block? 25 mm cable selection: flexible wire with wire terminal
Power circuit: What is the outer diameter of the 10... 120 mm2 terminal block? 25 mm cable selection: Hardwire without wire terminal
Power circuit: What is the outer diameter of the 10... 50 mm2 terminal block? 25 mm cable selection: Hardwire without wire terminal
Control Circuit: Bolt Tightening 1... 2.5 mm2 Cable Selection: Flexible Wire without Cable Terminal
Control Circuit: Bolt Tightening 2 1... 2.5 mm2 Cable Selection: Flexible Wire without Cable Terminal
Control Circuit: Bolt Tightening 1... 2.5 mm2 Cable Selection: Hardwire without Cable Terminal
Control Circuit: Bolt Tightening 2 1... 2.5 mm2 Cable Selection: Hardwire without Cable Terminal
tightening torque Control circuit: 1.2 N.m fastened with a screwdriver using bolts? 6 flat mouth
Control circuit: 1.2 N.m fastened with a screwdriver No. 2 cross screw using bolts
Power circuit: 12 N.m, secured with bolts in a hexagonal shape of 4 mm
Power circuit: 12 N.m via cable connector hexagonal 13 mm screw: M8
Control circuit: 1.2 N.m fastened with bolts using a screwdriver pozidriv No 2
Installation method rail mounting
Bottom plate installation
electrical life 0.5 Mcycles 250 A AC-1 Ue 条件下 <= 440='' v=''>0.9 Mcycles 115 A AC-3 Ue 条件下 <= 440='' v=''>1.4 Mcycles 80 A AC-3 Ue 条件下 660/690 V
mechanical life 8 Mcycles
Safety and reliability level B10d=1369863 nominal load contactors comply with EN/ISO 13849-1
The contactor with B10d=20000000 mechanical loads complies with EN/ISO 13849-1
working altitude 3000 meters without
model LC1D
meet the standard GB 14048.4
IEC 60947-4-1
IEC 60947-1
Product Certification CCC
CE
UKCA
environment
Surrounding air temperature 60... 70 ° C (allowed under Uc)
Storage environment temperature -60…80 °C
Fire resistance and ability to withstand abnormal high temperatures 850 ° C complies with IEC 60695-2-11
height 158 mm
width 120 mm
depth 136 mm
Net weight 2.5 kg
packaging unit
Unit category of packaging 1 PCE
per kilogram 1
package weight 2531.08 g
Packaging 1 Height 17.5 cm