Supplier of imported hydrogen leak detector

NegotiableUpdate on 04/29
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Hydrogen Power UST Germany UST hydrogen leak detector is an H2 detector with a detection range ranging from a very small PPM to 1000PPM. The bendable PRUFER flex is not a testing device, but a gas leak detector and cannot be used as a personal protective device. Suitable for use in hydrogen powered vehicles, refueling stations, hydrogen plants, etc.

Product Details

Introduction to HydrogenPower UST Germany UST hydrogen leak detector:

UST Umweltsensortechnik GmbH is a successful medium-sized enterprise, recognized as a company that develops and produces ceramic sensor technology, and has achieved success in the market. The fundamental key to the success of the company's business is market driven development, producing innovative ceramic sensor components for gas, temperature, and flow, as well as innovative equipment for gas detection. PRUFER flex is an H2 detector with a detection range ranging from a very small PPM to 1000PPM.

HydrogenPower USTUST Ulster, GermanyHydrogen leak detectorThe bendable PRUFER flex is not a testing device, but a gas leak detector and cannot be used as a personal protective device.


637774955162117458348.jpg


Main features of the product:

Ppm parts per million, abbreviated as ppm (Parts Per Million), is mainly used in the gas industry to refer to low concentrations. 1ppm is one cubic centimeter of the gas in one cubic meter of air.
1 ppm = 0.0001 Vol.%, 0.1% gas = 1000 ppm。

The lower explosive limit (LEL) of combustible gas reaches a certain concentration, and once it comes into contact with a fire source, an explosion will occur. This point is also different for different gases. The lower explosive limit is not related to the concentration of 4.0-4.4% mixed methane gas, as long as there is a small amount of contact with explosive mixtures.


Technical parameters of UST Hydrogen Power hydrogen leak detector in Germany:

scope H2:1ppm – 999ppm
Display error

10ppm: 30%

100ppm:20%

200ppm:20%

resolution 1ppm / 0.1 Vol.%
Test gas calibration Methane in 1.0 vol.% synthetic gas
Functional testing of the tested gas Methane in 100ppm synthetic gas
Detection Principle Gas sensitive semiconductor GGS 3000
display The liquid crystal display stage ranges from 0ppm to 1.0 vol.%, with concentration values represented by PPM and vol.%
Background concentration 250ppm
Reaction time (T90) 2-3 seconds
Operating temperature -20 - +50°C
Storage temperature -25 - +50°C

storage humidity

20 - 80%
storage environment Clean and prevent chemical media such as siliconewait
sound signal Depending on the concentration, it can be turned off and emit continuous audio when it exceeds the lower explosive limit
Battery status Display battery symbol, green operation light flashing, continuous operation display for 15 minutes
size 190 x 40 x 28 mm (length * width * height)
weight 320 g