E-mail
m975@163.com
-
Phone
13370059858
-
Address
Floor 2-3, No. 107 Xizha Branch Road, Shanghai
Shanghai Jinggong Industrial Co., Ltd
m975@163.com
13370059858
Floor 2-3, No. 107 Xizha Branch Road, Shanghai
The wider diameter of the Delger detection tube makes reading very convenient. The large spacing scale markings provide clear and decisive measurement results. The color change of the reagent inside the tube can be easily indicated by the length of the entire coloring agent. Many detection tubes have two sets of calibrated scales, so results can be easily obtained without further calculation.



A detection tube that only extracts a gas sample once does not always provide results quickly! Although many Delger detection tubes require multiple samples, the results are obtained in a very short time. Not only can you benefit from quick analysis, but a large volume of samples also helps to obtain accurate results.
Not all detection tubes are the same! Accurate detection results of Delger detection tube and Delger compressed air quality detector. The measurement error of most Delger detection tubes does not exceed ± 10%. This is determined by the design of colorimeters and constant volume vacuum pumps that have been manufactured for over 60 years. Each batch of detection tubes is calibrated separately to ensure quality, and each batch of detection tubes is regularly tested during the two-year storage period to ensure the accuracy of the entire service life of the detection tubes.
DrägerCompressed air detection tubeTwo years without calibration, the Delger detection tube is easy to read.

There are many types of Delger detection tubes! Compared to other manufacturers, it can detect more gases and has a wide measurement range. Delger has over 300 types of detection tubes that can accurately detect more than 500 types of gases.
Delger makes gas detection very easy. The Delger Accuro air pump does not require lubricating oil like a piston air pump. The air pump is made of corrosion-resistant non-metallic materials. It can withstand intense operation and harsh chemical environments. The Delger detection tube has been pre calibrated for two years. The Delger detection tube only needs to be stored away from direct sunlight and below 25 ℃. Any temperature controlled office meets the requirements.

Delger short-term testing common organic compound detection range and order number, if neededDrager compressed air detection tubewholesale priceYou can view more appendix information.
Name of detection tube |
measurement range |
Order Number |
Acetaldehyde 100/a |
100-1,000 ppm |
67 26 665 |
乙酸 Acetic Acid 5/a |
5-80 ppm |
67 22 101 |
Acetone 100/b |
100-12,000 ppm |
CH22901 |
Acetone 40/a |
40-800 ppm |
81 03 381 |
Acid Test Acid 5/a |
Qualitative Qualitative |
81 01 121 |
Acrylonitrile 0.5/a (5) |
0.5-20 ppm |
67 28 591 |
Acrylonitrile 5/b |
5-30 ppm |
CH26901 |
Air Current Tubes |
CH25301 |
|
|
Alcohol 25/a 50-4000 ppm isopropanol Lsopropanol 25-5000 ppm methanol Methanol |
81 01 631 |
|
Ammonia 2/a |
2-30 ppm |
67 33 231 |
Ammonia 5/b |
5-100 ppm |
81 01 941 |
Ammonia 5/a |
5-70 ppm |
CH20501 |
Ammonia 0.5%/a |
0.5-10 Vol.% |
CH31901 |
Aniline 0.5/a |
0.5-10 ppm |
67 33 171 |
Aniline 5/a |
1-20 ppm |
CH20401 |
Arsenic 0.05/a |
0.05-60 ppm |
CH25001 |
苯 Benzene 0.5/a |
0.5-10 ppm |
67 28 561 |
苯 Benzene 0.5/c(5) |
0.5-10 ppm |
81 01 841 |
苯 Benzene 2/a |
2-60 ppm |
81 01 231 |
苯 Benzene 5/a |
5-40 ppm |
67 18 801 |
苯 Benzene 5/b |
5-50 ppm |
67 28 071 |
Compressed air detection tube ordering information
The Delger compressed air detection tube is mainly used to detect the content of various impurities in compressed air. Currently, it mainly detects the oil content and water content of compressed air.
Description Product Name |
Delger detection tube name |
Pic No. Order Number |
Measurement range (20 ℃, 1013 hPa) |
Ammonia (for CO2) |
Ammonia water |
6733231 |
2 to 30ppm |
Carbon Dioxide 100/A-P |
Carbon dioxide |
6728521 |
100 to 3000 ppm |
Carbon Monoxide 5/A-P |
Carbon monoxide |
6728511 |
5 to 150 ppm |
Hydrogen Sulfide 0.2/a (for CO2) |
Hydrogen sulfide |
8101461 |
0.2-5ppm |
Hydrogen Sulfide 1/d (for MultiTest) |
Hydrogen sulfide |
8101831 |
1 to 20 ppm |
Nitrous Fumes 0.5/a (for MultiTest/CO2) |
Nitrogen oxides |
CH29401 |
0.5-10 ppm |
Oil 10/a-P |
Oil |
6728371 |
0.1 to 1.0 mg/m3 |
Oil impactor |
Oil box |
8103560 |
0.1,0.5,1.0 mg/m3 |
adapter for oil impactor |
Adapter |
8103557 |
|
oil PN (for Navy) |
Oil |
8103111 |
5mg/m3 |
oxygen 5%/b |
Oxygen |
6728081 |
5-23Vol% |
Phosphine |
|
CH31101 |
0.1-4ppm |
Sulfur Dioxide 0.5/a (for MultiTest/CO2) |
Sulfur dioxide |
6728491 |
1-25 ppm |
Sulfur Dioxide 1/a |
Sulfur dioxide |
CH31701 |
1-25ppm |
Water Vapour 5/a-P (for CO2) |
Water vapor |
6728531 |
2 to 450 mg/m3 |
Water Vapour 20/a-P (for HP/alpha) |
Water vapor |
8103061 |
20 to 1500 mg/m3 |