Beijing Hemu Technology provides rental services for Shimadzu second-hand liquid chromatographs, with Shimadzu LC-10A/20A/2010 in stock. Please feel free to inquire.

Product Details

High performance liquid chromatography is widely used in the fields of food, environment, chemical engineering, detection, teaching, and academic research, and is a precision analytical instrument widely used in sample analysis. Beijing Hemu Technology provides you with ShimadzuSecond hand liquid chromatography instrumentLeasing and sales business, including Shimadzu liquid chromatography LC-20AD/20AT/20AB, etc.


1. Infusion unit Prominence LC-20AD/20AT/20AB

LC-20AD infusion method: parallel double plunger

LC-20AT infusion method: series double plunger

LC-20AB infusion method: parallel double plunger (type 2)


2. Gradient system

LC-20AB gradient method: high-pressure mixing; Number of mixed solvents: 2 liquids

LC-20AD/20AT Low Voltage GE Specification; Gradient method: low-pressure mixing, maximum number of mixed solvents: 4 liquids


3. Detector

Prominence SPD-20A/SPD-M20A

SPD-20A UV detector:

Wavelength range: SPD-20A 190nm-700nm, SPD-20AV 190nm-900nm

Drift: 1 × 10-4AU/h

Linear:>2.5AU

Function: Dual wavelength detection at 190nm-370nm or above, proportional chromatogram output, wavelength scanning, time program

SPD-M20A diode array detector:

Light source: D2 lamp, W lamp

Number of diode components: 512

Wavelength range: 190nm-800nm

Wavelength accuracy: below 1nm

Wavelength precision: below 0.1nm

Noise: ± 0.3 × 10-5AU

Drift: 0.5 × 10-3AU/h

Linear:>2.0AU

Function: Contour line output, spectral retrieval


4. Prominence SIL-20A/20AC automatic sampler

Injection method: full volume injection, variable injection volume

Injection volume setting range: 0.1ul to 100ul (standard), 1ul to 2000mL (optional)

Injection volume precision: RSD: below 0.3% (under necessary conditions for 10mL injection)

Cross contamination: less than 0.005% (naphthalene, chlorhexidine)

Repeated injection times: 30/1 sample

Needle cleaning: set arbitrarily before and after injection

Sample cooler: SIL-20A without SIL-20AC module cooling and heating method, with moisture removal function at 4 ℃ -4


5. Column temperature box Prominence CTO-20A/20AC

Temperature regulation method: forced air circulation type

Cooling method: CTO-20A None, CTO-20AC Electronic Cooling

Temperature control precision: below 0.1 ℃

Temperature control range: CTO-20A (room temperature+10) ℃ -85 ℃, CTO-20AC (room temperature -10) ℃ -85 ℃

Storage space: W220 × H365 × D95mm

Can accommodate instruments: 2 manual samplers, gradient mixers, 2 high-pressure flow path switching valves, etc

Timer program: Linear temperature program

Safety measures: solvent sensor, temperature fuse, upper temperature limit


Beijing Hemu Technology Co., Ltd. provides you with information on the parameters, prices, models, principles, and more of Shimadzu liquid chromatography LC-10A/20A/2010Second hand liquid chromatography instrumentYou can consult the company's customer service hotline for information on renting and selling equipment 24/7.