High performance liquid chromatography is widely used in the fields of food, environment, chemical engineering, detection, teaching, and academic research, and is a precision analytical instrument widely used in sample analysis. Beijing Hemu Technology provides you with ShimadzuSecond hand liquid chromatography instrumentLeasing and sales business, including Shimadzu liquid chromatography LC-20AD/20AT/20AB, etc.
1. Infusion unit Prominence LC-20AD/20AT/20AB
LC-20AD infusion method: parallel double plunger
LC-20AT infusion method: series double plunger
LC-20AB infusion method: parallel double plunger (type 2)
2. Gradient system
LC-20AB gradient method: high-pressure mixing; Number of mixed solvents: 2 liquids
LC-20AD/20AT Low Voltage GE Specification; Gradient method: low-pressure mixing, maximum number of mixed solvents: 4 liquids
3. Detector
Prominence SPD-20A/SPD-M20A
SPD-20A UV detector:
Wavelength range: SPD-20A 190nm-700nm, SPD-20AV 190nm-900nm
Drift: 1 × 10-4AU/h
Linear:>2.5AU
Function: Dual wavelength detection at 190nm-370nm or above, proportional chromatogram output, wavelength scanning, time program
SPD-M20A diode array detector:
Light source: D2 lamp, W lamp
Number of diode components: 512
Wavelength range: 190nm-800nm
Wavelength accuracy: below 1nm
Wavelength precision: below 0.1nm
Noise: ± 0.3 × 10-5AU
Drift: 0.5 × 10-3AU/h
Linear:>2.0AU
Function: Contour line output, spectral retrieval
4. Prominence SIL-20A/20AC automatic sampler
Injection method: full volume injection, variable injection volume
Injection volume setting range: 0.1ul to 100ul (standard), 1ul to 2000mL (optional)
Injection volume precision: RSD: below 0.3% (under necessary conditions for 10mL injection)
Cross contamination: less than 0.005% (naphthalene, chlorhexidine)
Repeated injection times: 30/1 sample
Needle cleaning: set arbitrarily before and after injection
Sample cooler: SIL-20A without SIL-20AC module cooling and heating method, with moisture removal function at 4 ℃ -4
5. Column temperature box Prominence CTO-20A/20AC
Temperature regulation method: forced air circulation type
Cooling method: CTO-20A None, CTO-20AC Electronic Cooling
Temperature control precision: below 0.1 ℃
Temperature control range: CTO-20A (room temperature+10) ℃ -85 ℃, CTO-20AC (room temperature -10) ℃ -85 ℃
Storage space: W220 × H365 × D95mm
Can accommodate instruments: 2 manual samplers, gradient mixers, 2 high-pressure flow path switching valves, etc
Timer program: Linear temperature program
Safety measures: solvent sensor, temperature fuse, upper temperature limit
Beijing Hemu Technology Co., Ltd. provides you with information on the parameters, prices, models, principles, and more of Shimadzu liquid chromatography LC-10A/20A/2010Second hand liquid chromatography instrumentYou can consult the company's customer service hotline for information on renting and selling equipment 24/7.