SIBATA environmental detection micro pumpMP-Σ300NII.
SIBATA environmental detection micro pumpMP-Σ300NII.
The MP - ∑ series micro pump is a small, lightweight, portable, high-performance suction pump (air pump, air pump) with integrated flow measurement function. There are three basic types to choose from, ranging from 0.5 L/min, 3 L/min, and 5 L/min to different flow ranges. Due to the stable inhalation flow rate, it can be widely used for sampling harmful substances in working environments, indoor environments, air environments, and other environments.
Equipped with a flow sensor, it can directly measure the suction flow rate and display the instantaneous and cumulative flow rates digitally.
Built in constant current function to suppress the decrease in suction flow caused by increased suction pressure due to dust collection and other factors.
Timer sampling can be performed through four modes: manual, shutdown timer, volume timer, and loop timer.
-LCD screens are backlit, allowing for viewing of traffic even in the dark.
You can see the dirt on the backup filter.
Equipped with measurement data recording function, the past 10 measurement results can be viewed on the micro pump body and computer.
| Product Code | 080860-304 | |
|---|---|---|
| type | MP-Σ300NII. | |
| Measurement Mode | Manual, shutdown timer, Volium timer, cycle timer | |
| communication | Use dedicated communication software to read and set data | |
| Pumping method | Double diaphragm system | |
| traffic accuracy | Set flow rate within ± 5% | |
| flow meter | Mass flow sensor | |
| material | Pump head: ABS, POM, TPU, diaphragm: EPDM, valve: EPDM, housing: PC | |
| Variable flow range | 0.50~3.00 liters/minute | |
| Constant flow usage range | 0.5L/min:0~10.0kPa 1.0L/min:0~7.0kPa 2.0L/min:0~6.0kPa 3.0L/min:0~5.0kPa | |
| Time setting and display | Year/Month/Day, Hour: Minute | |
| Air inlet and exhaust outlet | Outer diameter: 6 mm and 8 mm (using pipes: inner diameter: 5 mm and 7 mm) | |
| Instantaneous flow display range | 0.20-4.50 liters per minute | |
| quality | 0.65 kg (including lithium-ion rechargeable battery) | |
| Time Settings | 0.00~999.59 (hours. minutes) | |
| display | LCD display (with backlight) | |
| Accumulated flow setting range | 0.0~9999.9 liters | |
| Accumulated traffic display | 0.0~19999.9L | |
| business environment | 0~40 ° C · 10~90% RH (no condensation) | |
| power | Lithium ion secondary battery, AA battery (8 AA batteries) (8 x per battery) (optional), AC adapter (optional) | |
| size | 145 (width) × 67 (depth) × 95 (height) | |
| accessory | Lithium ion secondary battery | |
| Price (excluding tax) | 98000 yen | |
| speech |
*The instantaneous flow rate and comprehensive flow rate are displayed as values equivalent to 25 ° C and 1 atmosphere at the time of shipment. You can also change the value to 20 ° C and 1 atmosphere by operating the screen. *Excluding chargers for lithium-ion secondary batteries. Need to use the fast charger QC-10N separately. *The working time is the reference value when unloaded at 25 ° C. *The battery life varies depending on the ambient temperature and usage history during operation. *The loop timer mode can repeat the timer operation up to 5 times. *To set a loop timer, a communication cable with MP ∑ NII./∑ N software is required. *To maintain product performance, we recommend that you request regular major repairs, calibration, and replacement of consumables every year. *Under special usage conditions, flow accuracy may not be met. *When using dry batteries, a separate dry battery unit DB-10N type is required. *The working time is the reference value when unloaded at 25 ° C. *To set a loop timer, a communication cable with MP - ∑ n software is required. |
|