Requirements for testing indicators and list of instruments and equipment for returning manure to the field in the livestock and poultry manure resource utilization project
According to the Standards Committee agriculture and rural areas ecological environmentThe Guiding Opinions on Promoting the Construction of Standard System for Resource Utilization of Livestock and Poultry Manure were jointly issued. There are two application techniques for manure utilization: solid manure returning to the field and liquid manure returning to the field.
The indicator requirements include:restrictionindicatorAnd technical indicators.
restrictionThe indicators are mainly based on three criteria,GB 38400-2019 Toxic and Harmful Substances in FertilizersRestriction requirements、 NY/T 1334-2007 Guidelines for the Safe Use of Livestock and Poultry Manure, Harmful Substances in Returning Livestock and Poultry Manure to the Fieldrestriction standard.
What is required to be tested in the standardlimit indicatorThere are: total cadmium, total mercury, total arsenic, total lead, total chromium, total TA, urea, mortality rate of roundworm eggs, number of fecal coliforms, total nickel, total cobalt, total vanadium, and total antimony; Copper and zinc.
Technical indicators, mainly based on standards,NY/T 3877-2021 Calculation Method for Land Carrying Capacity of Livestock and Poultry Manure.
The technical indicators required in the standard include nitrogen, phosphorus, and potassium.
According to the guidance and relevant standards, Zhengzhou Pengjian Agricultural Technology has compiled a set of laboratory instruments and equipment suitable for use in the county wide promotion project of livestock and poultry manure resource utilization, supporting bidding and project cooperation.
serial number |
Product List |
Specifications/Model number |
quantity |
remark |
1 |
High precision intelligent organicFertilizer component detector |
PJ-TXC04 |
1Taiwan |
Detect organic fertilizer nitrogen, phosphorus, potassium, organic matter, pH, chloride ions, heavy metals |
2 |
Flame photometer |
FP6400 |
1Taiwan |
Potassium determination |
3 |
spectrophotometer |
722 |
1Taiwan |
Phosphorus determination |
4 |
Kjeldahl nitrogen analyzer |
containeighty percentKong digestion furnace |
1Taiwan |
Nitrogen determination |
5 |
Organic fertilizer electronic moisture analyzer |
DSH 110g/5mg |
1Taiwan |
Rapid determination of moisture content |
6 |
desktoppH meter |
PHS-3C |
1Taiwan |
Detect acidity and alkalinity(PH) |
7 |
Constant temperature and humidity biochemical incubator |
150LStudio size50*40*75cm |
1Taiwan |
Sample cultivation |
8 |
Ultrapure Water System |
20L/h |
1Taiwan |
Provide distilled water |
9 |
electric furnace+Asbestos net |
Quadruple1kw |
1Taiwan |
Heating and dissolving the sample |
10 |
vacuum drying oven |
53L, Automatic start/stop of vacuum pump, studio size 415 * 345 * 370mm |
1Taiwan |
vacuum drying |
11 |
constant temperaturewater bath |
sixKong |
1Taiwan |
Accelerate the dissolution of samples |
12 |
Sample shrinking machine |
stainless steelThe particle size is smaller than3mm |
1Taiwan |
Split Samples |
13 |
Solid sample crusher |
800 grams |
1Taiwan |
Crush the sample |
14 |
Fertilizer sampler |
Straight handle,length100cm |
1document |
Organic fertilizer sampling |
15 |
Reciprocating oscillator |
Digital display speed regulation0-300r/min |
1Taiwan |
Accelerate the dissolution of samples |
16 |
electronic balance |
range220g/accuracy 0.0001g |
1Taiwan |
Weigh the sample |
17 |
Biological microscope (with display) |
Measure bacterial activity |
1Taiwan |
bacteria/Fungal/Microbial Observation |
18 |
autoclave |
40L, Self controlled type |
1Taiwan |
High-pressure sterilization |
19 |
clean bench |
Double sided,studio dimensions1360*600*520mm |
1Taiwan |
Provide a dust-free environment |
20 |
high-speed centrifuge |
250mL * 4 tubes |
1Taiwan |
Measuring the mortality rate of roundworm eggs |
21 |
Test sieve |
10 20 mesh sieves |
1set |
Screen the sample |
22 |
pipette gun |
0.1-1ml and 1-10ml |
1set |
sampling |
23 |
constant temperature drying oven |
studio100*100*100cm |
1Taiwan |
Dry cultivation samples |
24 |
beaker |
100、500、1000ml |
3set |
container |
25 |
petri dish |
60、75、90、100mm |
10set |
Sample cultivation |
26 |
reagent bottle |
100、500、1000ml |
3set |
Place sample vessels |
27 |
One set of filtration device |
vacuum pump+Filter bottle+funnel |
1set |
Micro porous cotton gel filter membrane (diameter)35mm, Aperture 0.65-0.8 micrometers) |
28 |
Test Kit |
matchingPJ-TXC04 |
1set |
Nitrogen, phosphorus, potassium, organic matter, humic acid11 trace elements5Heavy metal reagents |
29 |
Heavy metal arsenic reaction device |
matchingPJ-TXC04 |
1set |
Detecting heavy metal arsenic |
30 |
Organic fertilizer thermometer |
PJ-YWD |
1Taiwan |
Production line temperature detection |
31 |
Organic fertilizer water separation meter |
PJ-FSC |
1Taiwan |
Moisture detection on the production line |
32 |
fume hood |
Floor standing,150*65*190cm |
1Taiwan |
Pollutant gas emissions |
33 |
burette |
10、25、50ml |
3set |
Titration sample |
34 |
Erlenmeyer flask |
100、250、1000ml |
3set |
Place sample vessels |
35 |
volumetric flask |
50、100、250、500、1000ml |
3set |
Place sample vessels |
36 |
Alkali hydrolysis nitrogen reaction device |
matchingPJ-TXC04 |
1set |
Detecting alkaline hydrolyzed nitrogen |
37 |
Atomic absorption spectrophotometer |
Zca- 1000 |
1 unit |
Heavy metal determination |
38 |
Inductively Coupled Plasma Emission Spectrometer |
ICP700T |
1 unit |
Heavy metal determination |