LMI Milton Roy metering pump GM seriesSimple, economical, and sturdy, designed for efficient water treatment applications with low pressure and high flow rates. Capable of handling flow rates of up to 175psi and 475gph (1800l/h). Combining the design and production process of heavy-duty industrial drive technology, this mechanical driven diaphragm pump reduces flow restrictions, reduces the possibility of hydraulic oil contamination by the medium, and ensures safe transportation.
Advantages:
Design is concise. The pump has fewer movable parts and is designed to be compact and lightweight.
More flexibility. The G series features a variable frequency drive with stroke adjustment. There are three foot sizes to choose from, with multiple hydraulic ends available for selection.
Reliable performance. Corrosion resistant plastic or aluminum casing can reduce the heat accumulation generated by high-performance motors in harsh environments.
Long term cost advantage. This pump has reliable performance, minimal maintenance, and reduces the overall cost of using the pump throughout its entire lifecycle.
Performance parameters:
Z high pressure/Z high flow 175psi (12 bar)
High flow rate can reach 475gph (1800l/h)
Adjustment ratio of 10:1, steady-state accuracy of+/-1%
Application: The GM series metering pump is suitable for various applications such as chemical dosing, water treatment and sewage treatment plants, industrial processes, agriculture, etc. These pumps have reliable performance and are capable of adding various chemical agents, such as ferric chloride, aluminum sulfate, high molecular weight polymers, alkali metals, sodium hydroxide, acids, anti scaling and anti foaming agents, as well as other coagulation/flocculent substances, slurry treatment, pH control and adjustment, and desalination.
LMI Milton Roy metering pump GM series
The stroke can be adjusted under both static and dynamic conditions
Z large liquid temperature 40 ℃
Steady state accuracy: ± 2% (10%~99%)
Z large suction range: 3m water column
• Z-high suction pressure: 20m water column
• Optional dual diaphragm pump head structure
Suggested maintenance cycle: ≤ 1.0MPa4000h ≤ 0.7MPa8000h
Automatic control mode selection
Electric stroke controller
Accept external control signals, adjust the stroke length of the metering pump, and thereby change the output flow rate of the metering pump.
Choose HE type for G series metering pumps. The GB series can choose ECC explosion-proof type.
• Variable frequency controller
Accept external control signals and adjust the stroke speed of the metering pump.
Power supply: 380V/50Hz three-phase/220V/50Hz single-phase
Control signal: 4-20mA
Motor switch controller (VARIPULSE)
Reverse applied to GM series metering pumps, used to control three-phase motors, change stroke frequency, and thereby regulate the output flow of the metering pump.
V-type - integrated installation with metering pump, VR type - separate installation with metering pump
Technical parameters of electric stroke controller | ||
type |
HE |
ECC(GB) |
power supply |
220V±10%,50/60Hz |
|
control signal |
4~20mA |
|
Protection level |
IP65 |
NEMA4 |
feedback signal |
4~20mA |
4~20mA |
power consumption |
20VA |
N/A |
ambient temperature |
-10℃~+40℃ |
-40℃~+50℃ |
input impedance |
120Ω |
250Ω |
output load |
100~500Ω |
N/A |
execution time |
0~99%/150S |
0~99%/180S |
Explosion-proof rating |
none |
Zone 1, Class I, Groups B, C, and D |
lubricating oil
Pump type |
volume |
Environmental temperature<-5 ℃<> |
Environmental temperature ≥ -5 ℃ |
GB |
3L |
Mobil 600XP68 |
Mobil 600XP220 |
GM |
0.8L |
Mobil 600XP68 |
Mobil 600XP220 |
Material of pump head overcurrent components
Pump head material |
valve body |
valve seat |
Valve ball |
diaphragm |
sealing ring |
import and export connections |
||
GM0002~GM0050 | ||||||||
PVC |
PVDF |
PVDF |
ceramics |
PTFE |
fluororubber |
PVC |
||
PVDF |
PVDF |
PVDF |
ceramics |
PTFE |
PTFE |
PVDF |
||
316SS |
316SS |
316SS |
316SS |
PTFE |
fluororubber |
316SS |
||
GM0090~GM0500 | ||||||||
PVC |
PVC |
PVC |
glass |
PTFE |
fluororubber |
PVC |
||
PVDF |
PVDF |
PVDF |
ceramics |
PTFE |
PTFE |
PVDF |
||
316SS |
316SS |
316SS |
316SS |
PTFE |
fluororubber |
316SS |
||
GB0080~GB1500 | ||||||||
PVC |
PVC |
PVC |
ceramics |
PTFE |
fluororubber |
PVC |
||
PVDF |
PVDF |
PVDF |
ceramics |
PTFE |
PTFE |
PVDF |
||
316SS |
316SS |
316SS |
316SS |
PTFE |
Fluororubber/PTFE |
316SS |
||
GB1800 | ||||||||
Pump head material |
Valve body/liner |
Valve plate/lift limit plate |
spring |
diaphragm |
sealing ring |
import and export connections |
||
PVC |
PVC |
PVC |
Hastelloy C |
PTFE |
fluororubber |
PVC |
||
PVDF |
PVDF |
PVDF |
Hastelloy C |
PTFE |
PTFE |
PVDF |
||
316SS |
316SS |
316SS |
Hastelloy C |
PTFE |
fluororubber |
316SS |
||
Technical parameters of VARIPULSE motor controller | |
Features: |
|
Smooth pulse design, no impact |
The stroke can be adjusted under both static and dynamic conditions |
Multiple materials and pump head structures are available for selection |
• Optional electric stroke controller |
Mechanical driven PTFE membrane |
• Liquid temperature 40 ℃ |
• Manual/automatic stroke adjustment is optional |
Steady state accuracy ± 2% (10%~99%) |
• Stroke adjustable from 0% to 99% (automatic/manual) |
• Suction stroke of 4m water column |
• Optional dual diaphragm pump head structure |
• Inhalation pressure: 20m water column |
Suggested maintenance cycle: ≤ 1.0MPa 4000h ≤ 0.7MPa 8000h | |
Optional motor controller for external signal automatic control, motor frequency adjustable from 0 to 99% (GM pump automatic control mode) | |
Power supply: 220V (± 10%)/50HZ single-phase |
Motor power: 0.09~0.75KW |
Protection level: IP55 |
Environmental temperature: -20~40 ℃ |
Fault indication: on-site indication |
Passive contact output (250V/1A) |
Control method 1: Analog signal control |
Control input signal: 4~20mA |
Input impedance: 250 ohms |
Stroke frequency adjustment: 0~144spm |
Control mode 2: Manual potentiometer adjustment |
Adjustment range: 6-144spm |
Control method 3: Pulse signal control |
Control input signal: passive contact or open circuit collector signal |
Pulse frequency: Max. 144 pulses/min (1 pulse=output per stroke) Applicable metering pumps: GM0010, GM0050, GM0170,GM0240, GM0330, GM0400 | |
Note: Metering pumps equipped with VARIPULSE control must be equipped with sensing probes. The metering pump with a stroke frequency of 144spm can be adapted to the VRIPULSE controller. | |
Warning! When selecting the application of this series of metering pumps, it is recommended to install a pressure relief valve on the pump outlet pipeline. Please refer to the metering pump system attachment (typical configuration diagram) for details. | |