E-mail
njhxsysb@163.com
-
Phone
15851853397
-
Address
No. 109 Lanhua Road, Qiaolin Economic Development Zone, Pukou District, Nanjing
Nanjing Hengxing Experimental Equipment Co., Ltd
njhxsysb@163.com
15851853397
No. 109 Lanhua Road, Qiaolin Economic Development Zone, Pukou District, Nanjing
Precision constant temperature water bathDesign features:
1. This is a practical and precise productSuper constant temperature water bathThe inner liner is made of all stainless steel SUS304; Durable, beautiful and atmospheric, with a lifespan of over 10 years!
2. The entire temperature control system adopts microcomputer PID intelligent programming. After setting the temperature, it automatically and precisely controls the temperature. The actual temperature and set temperature of the water temperature are displayed with high precision of 0.01 or 0.1 ℃ respectively. The centrifugal cycle design is adopted to make the temperature at multiple points basically consistent, and the temperature fluctuation is ≤± 0.05 ℃; When the resolution is 0.1 ℃, the fluctuation of water temperature is controlled within ≤± 0.5 ℃. So according to your precision requirements, you can choose different precision and prices.
3. Introduction to the difference between internal circulation and external circulation: Internal circulationhigh temperatureconstant temperature bathMainly used for testing samples or containers placed in a water tank, the internal circulation type has a larger circulation flow rate than the external circulation type, and the water temperature will be more uniform; The external circulation ring is mainly used to connect external equipment through a circulation hose, and continuously circulate hot water to maintain high temperature and temperature on external equipment or container jackets. Due to the large heat dissipation during external circulation, the accuracy is relatively lower compared to internal circulation. So users should pay attention to the difference in this item when selecting, and choose the product according to their own usage needs.
4. The internal circulation adopts isolated centrifugal blades for stirring, resulting in a uniform temperature field and greatly improving temperature control accuracy and uniformity.
5. It has functions such as overcurrent protection, safety grounding, digital temperature correction, sensor open circuit and short circuit alarm, over temperature alarm, and automatic recovery after power outage, greatly improving work efficiency.
6. The configuration of using power supply AC 220V 50HZ 0.5~3KW varies
Precision constant temperature water bathModel and parameters:
|
model |
Temperature range ℃ |
Temperature fluctuation degree ℃ |
Dimensions inside the slot (length * width * depth mm) |
Groove depth mm |
Slot size mm |
Overall dimensions mm |
Loop method |
|
ST-RT-1A |
Room temperature+5~100 |
±0.05 |
130*60*150 |
150 |
130*60 |
330*220*360 |
internal circulation |
|
ST-RT-1B |
Room temperature+5~100 |
±0.5 |
|||||
|
ST-RT-2A |
Room temperature+5~100 |
±0.05 |
130*120*150 |
150 |
125*120 |
330*280*360 |
internal circulation |
|
ST-RT-2B |
Room temperature+5~100 |
±0.5 |
|||||
|
ST-RT-5A |
Room temperature+5~100 |
±0.05 |
250*150*150 |
150 |
245*150 |
450*310*360 |
internal circulation |
|
ST-RT-5B |
Room temperature+5~100 |
±0.5 |
internal circulation |
||||
|
ST-RT-5C |
Room temperature+5~100 |
±0.5 |
External circulation flow rate 4L/min |
||||
|
ST-RT-10A |
Room temperature+5~100 |
±0.05 |
280*190*200 |
200 |
275*190 |
480*350*390 |
internal circulation |
|
ST-RT-10B |
Room temperature+5~100 |
±0.5 |
internal circulation |
||||
|
ST-RT-10C |
Room temperature+5~100 |
±0.5 |
External circulation flow rate 4L/min |
||||
|
ST-RT-15A |
Room temperature+5~100 |
±0.05 |
280*250*200 |
200 |
275*250 |
480*410*390 |
internal circulation |
|
ST-RT-15B |
Room temperature+5~100 |
±0.5 |
internal circulation |
||||
|
ST-RT-15C |
Room temperature+5~100 |
±0.5 |
External circulation flow rate 4L/min |
||||
|
ST-RT-18A |
Room temperature+5~100 |
±0.05 |
320*280*200 |
200 |
315*280 |
520*440*390 |
internal circulation |
|
ST-RT-18B |
Room temperature+5~100 |
±0.5 |
internal circulation |
||||
|
ST-RT-18C |
Room temperature+5~100 |
±0.5 |
External circulation flow rate 4L/min |
||||
|
ST-RT-25A |
Room temperature+5~100 |
±0.05 |
280*250*300 |
300 |
275*250 |
480*410*490 |
internal circulation |
|
ST-RT-25B |
Room temperature+5~100 |
±0.5 |
internal circulation |
||||
|
ST-RT-25C |
Room temperature+5~100 |
±0.5 |
External circulation flow rate 4L/min |
||||
|
ST-RT-30A |
Room temperature+5~100 |
±0.05 |
400*330*230 |
230 |
395*330 |
600*490*420 |
internal circulation |
|
ST-RT-30B |
Room temperature+5~100 |
±0.5 |
internal circulation |
||||
|
ST-RT-30C |
Room temperature+5~100 |
±0.5 |
External circulation flow rate 4L/min |
||||
|
We are a professional manufacturer of constant temperature water tanks. If the above parameters do not meet your usage requirements, the company can also customize according to your needs. Non standard customization: Mr. Zhang |
|
||||||