Hash PRO-P3 online pH meter
Working Principle:
Detection principle: The main measuring components of a pH meter are a glass electrode and a reference electrode. The glass electrode is sensitive to pH, while the reference electrode is relatively stable. Placing the two electrodes of pH together in the same solution forms a primary cell, and the potential of this primary cell is the algebraic sum of the glass electrolysis and the reference electrode. The reference electrode potential of a pH meter is stable, so under constant temperature, the potential change of the original battery composed of solution and battery is only related to the potential of the glass electrode, which depends on the pH of the solution to be measured. Therefore, by measuring the potential change, the pH value of the pH solution can be obtained.

Technical Specifications:
P53 (discontinued) |
SC200 |
P33 |
PRO-P3 |
|
pH |
-2.00 — +14.00 |
-2.00 — +14.00 |
-2.00 — +14.00 |
-2.00 — +14.00 |
ORP |
-2100 — +2100mV |
-2100 — +2100mV |
-2100 — +2100mV |
-2100 — +2100mV |
temperature |
-20.0 — +200.0℃ |
-20.0 — +200.0℃ |
-20.0 — +200.0℃ |
-20.0 — +200.0℃ |
Number of sensors |
1 |
1-2 |
1 |
1 |
number of relays |
4 |
4 |
2 |
N/A |
Independent output |
2 pieces of 0/4-20mA |
2 pieces of 0/4-20mA |
2 pieces of 0/4-20mA |
1 0/4-20mA |
Shell protection level |
NEMA4X(IP65),1/2DIN |
NEMA4X(IP66),1/2DIN |
NEMA4X(面板)(IP65),1/2DIN |
NEMA4X |
Explosion-proof rating |
/ |
/ |
/ |
Class I,DivissionII, Group A,B,C,D,T5 |
Performance/Stability |
0.2% of the range every 24 hours, |
- |
0.2% of the range every 24 hours, |
0.05% of full range |
Performance/repeatability |
0.1% or better of the measuring range |
0.1% or better of the measuring range |
0.1% or better of the measuring range |
0.05% of the measuring range |
Power requirements |
190-260VAC |
190-260VAC,24VDC |
190-260VAC |
16-30VDC |
Installation method |
Panel mounted, wall mounted, or pipe mounted |
Panel mounted, wall mounted, or pipe mounted |
panel-type |
Panel mounted, wall mounted, or pipe mounted |
Installation occasion |
High protection level, |
High protection level, |
Low protection level, |
Explosion proof location, 24VDC |

Ordering Guide:
Here isGLI pH/ORPThe analyzer controller and installation accessories need to be ordered separatelyGLI 3/4Inch composite electrode or differential electrode probe:
LXV404.99.00102 sc200Controller, analog, single channel,220V
P33A1NN pH/ORPcontroller190 -260Vac
PRO-P3A1N pH/ORPTransmitter,16-30Vdc