Load tester (with peak value)Main technical parameters:
1 |
purpose |
Suitable for pressure measurement within 2000.0KN |
2 |
precision |
≤1% |
3 |
Power display of the largest small unit |
0.1KN |
4 |
power supply |
AC 220V ± 5% (50Hz) |
5 |
zero adjustment |
automatic |
6 |
Environmental temperature for use |
-5℃ ~ +45℃ |
7 |
Environmental humidity for use |
85% (relative humidity) |
8 |
Use without strong magnetic fields or noise sources around |
|
This load tester is a dual window display instrument that can display peak values; Accept customized customer parameters!!
Load tester (with peak value)Precautions:
1The power supply voltage must be accurate and error free during use
2The cable connecting the sensor to the host must not have any intermediate joints. If it is damaged, the cable must be replaced and the wiring must be accurate.
3When using, it is necessary to follow the instructions and operate according to the prescribed procedures. In case of operation errors or display errors, please press the "reset" button and operate again.
4During the loading process, the instrument must not be equipped with a "reset" button, otherwise the displayed force value will be incorrect. After unloading, press the "reset" button again in an unloaded state to reset the instrument to normal operation.
Load tester (with peak value)Common faults and their solutions
1No display after startup
Fault cause: ① Short circuit of power cord or failure to connect power supply
② Poor plug contact or damaged switch
③ The fuse is broken
④ Abnormal source voltage
Exclusion method: ① Check the power cord connector and repair it
② Replace the power plug or switch
③ Replace the fuse
④ Install a voltage regulator power supply
2The instrument display is garbled or0—9A number
Reason for malfunction: ① Abnormal power supply voltage
② Poor contact of sensor connection wire or sensor malfunction
③CPUAbnormal operation
Exclusion method: ① Check the power supply voltage and install a regulated power supply
② Replace the sensor wiring or sensor
③ Press the "Reset" button or turn off the local power and then turn it back on
The load tester (with peak value) is suitable for testing the compressive strength of various cement and concrete products. The mechanical performance tests of upper and lower water pipes, pipe piles, and various rigid and non rigid materials show that the product meets GB/T16752 and third-party testing standards.