Welcome Customer !

Membership

Help

Shanghai Kaitai Pump Manufacturing Co., Ltd
Custom manufacturer

Main Products:

ag-mach>Products

Shanghai Kaitai Pump Manufacturing Co., Ltd

  • E-mail

    139170592@qq.com

  • Phone

  • Address

    No. 229, Lane 2928, Jihe Road, Qingpu District, Shanghai

Contact Now

CQB-G series stainless steel high-temperature insulation magnetic pump

NegotiableUpdate on 10/09
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

CQB-G series stainless steel high-temperature insulation magnetic pump

Product Details

Product Overview:
The CQB-G high-temperature insulation pump adopts a multiple circulation cooling structure to ensure the reliability and stability of the original power and magnetic transmission. At the same time, the use of column pin couplings reduces the noise and vibration of the pump. The detachable and column pin couplings are used simultaneously, which increases the structure of the pump and is more conducive to heat dissipation. At the same time, it is also very convenient for users to repair or replace parts. A cooling fan blade is also designed on the outer rotor of the pump to ensure the stability of the magnetic steel. This series of pumps is suitable for transporting high-temperature media with a temperature of ≤ 300 ℃.
Installation and debugging
(1) High temperature magnetic pumps should be installed horizontally Before driving, check the lubricating oil level in the cooling tank If the oil level is too low, it should be replenished in a timely manner. Before starting the pump Firstly, the cooling water circuit should be opened The opening degree of the inlet valve should be adjusted according to the temperature of the cooling outlet pipe after the pump is working normally.
(2) When the suction liquid level is higher than the axis of the fruit Open the suction pipe valve before starting If the suction liquid level is lower than the pump axis line The pipeline needs to be equipped with a bottom valve.
(3) The pump should be inspected before use The motor fan blades should rotate flexibly No jamming or abnormal noise All fasteners should be tightened.
(4) Check if the rotation direction of the motor is consistent with the direction mark of the magnetic pump.
(5) After the motor is started Slowly open the discharge valve After the pump enters normal working condition Adjust the discharge valve to the desired opening.
Before the pump stops working The discharge valve should be closed first Then cut off the power Close the cooling water pipe valve again.
Performance parameters:
This data is for reference only.
model traffic
Q
m3/h
head
H
m
Net Positive Suction Head (NPSH)
NPSH
m
speed
n
r/min
shaft power
Pa
Kw
efficiency
or
%
Equipped with electric motor power Kw
Medium density g/cm3
≤1 ≤1.3 ≤1.84
CQB-G 32-20-125 1.9
3.2
3.8
22
20
18.5
2900 0.49
0.58
0.62
23
30
31
Y 801-2
YB
0.75
Y 802-2
YB
1.1
Y 90S-2
YB
1.5
CQB-G 32-20-160 1.9
3.2
3.8
34
32
29
2900 0.84
0.99
1.03
21
28
29
Y 802-2
YB
1.1
Y 90S-2
YB
1.5
Y 90L-2
YB
2.2
CQB-G 40-20-105 3.8
6.3
7.5
13
12.5
11
2900 0.42
0.55
0.56
32
29
40
Y 801-2
YB
0.75
Y 802-2
YB
1.1
Y 90S-2
YB
1.5
CQB-G 40-25-125 3.8
6.3
7.5
22
20
18.5
2900 0.81
0.98
1.05
28
35
36
Y 802-2
YB
1.1
Y 90L-2
YB
2.2
Y 100L-2
YB
3.0
CQB-G 40-25-160 3.8
6.3
7.5
34
32
29
2900 1.41
1.72
1.79
25
32
33
Y 90L-2
YB
2.2
Y 100L-2
YB
3.0
Y 112M-2
YB
4.0
CQB-G 40-25-200 3.8
6.3
7.5
52.5
50
48
2900 3.02
3.43
3.77
18
25
26
Y 112M-2
YB
4.0
Y 132S1-2
YB
5.5
Y 132S2-2
YB
7.5
CQB-G 50-40-85 7.5
12.5
15
9
8
7.5
3.5
3.5
4.0
2900 0.46
0.56
0.61
40
49
50
Y 801-2
YB
0.75
Y 802-2
YB
1.1
Y 90S-2
YB
1.5
CQB-G 50-32-105 7.5
12.5
15
13
12.5
11
3.5
3.5
4.0
2900 0.760
0.91
0.94
35
47
48
Y 802-2
YB
1.1
Y 90S-2
YB
1.5
Y 90L-2
YB
2.2
CQB-G 50-32-125 7.5
12.5
15
22
20
18.5
3.5
3.5
4.0
2900 1.49
1.62
1.63
30
42
43
Y 90L-2
YB
2.2
Y 100L-2
YB
3.0
Y 112M-2
YB
4.0
CQB-G 50-32-160 7.5
12.5
15
34
32
29
3.5
3.5
4.0
2900 2.48
2.79
2.96
28
39
40
Y 100L-2
YB
3.0
Y 112M-2
YB
4.0
Y 132S1-2
YB
5.5
CQB-G 50-32-200 7.5
12.5
15
52.5
50
48
3.5
3.5
4.0
2900 5.10
5.49
6.13
21
31
32
Y 132S2-2
YB
7.5
Y 132S2-2
YB
7.5
Y 160M1-2
YB
11
CQB-G 50-32-250 7.5
12.5
15
82
80
78.5
3.5
3.5
4.0
2900 9.57
10.89
13.32
17.5
25
26
Y 160M2-2
YB
3.0
Y 160M2-1
YB
8.5
Y 180M-2
YB
5.5
CQB-G 65-50-125 15
25
30
22
20
18.5
3.5
3.5
4.0
2900 2.25
2.67
2.91
40
51
52
Y 100L-2
YB
3.0
Y 112M-2
YB
4.0
Y 132S1-2
YB
5.5
CQB-G 65-50-160 15
25
30
34
32
29.5
3.5
3.5
4.0
2900 4.34
5.07
5.48
32
43
44
Y 132S1-2
YB
5.5
Y 132S2-2
YB
7.5
Y 160M1-2
YB
11
CQB-G 65-40-200 15
25
30
53
50
47
3.5
3.5
4.0
2900 8.66
9.20
10.1
25
37
38
Y 160M1-2
YB
11
Y 160M2-2
YB
15
Y 160L-2
YB
18.5
CQB-G 65-40-250 15
25
30
82
80
78.5
3.5
3.5
4.0
2900 13.4
14.72
16.88
25
37
38
Y 160L-2
YB
18.5
Y 180M-2
YB
22
Y 200L1-2
YB
30
CQB-G 80-65-125 30
50
60
22.5
20
18
4.0
4.0
4.5
2900 4.48
5.24
5.55
41
52
53
Y 132S1-2
YB
5.5
Y 132S2-2
YB
7.5
Y 160M1-2
YB
11
CQB-G 80-65-160 30
50
60
34
32
29
4.0
4.0
4.5
2900 7.72
9.08
9.67
36
48
49
Y 160M1-2
YB
11
Y 160M2-2
YB
15
Y 160L-2
YB
18.5
CQB-G 80-50-200 30
50
60
53
50
47
4.0
4.0
4.5
2900 12.03
14.80
16.34
36
46
47
Y 160L-2
YB
18.5
Y 180M-2
YB
22
Y 200L1-2
YB
30
CQB-G 80-50-250 30
50
60
84
80
75
4.0
4.0
4.5
2900 19.06
23.08
26.07
36
46
47
Y 200L1-2
YB
30
Y 220L2-2
YB
37
Y 225M-2
YB
45
CQB-G 100-80-125 60
100
120
23
20
16.5
4.0
4.0
4.5
2900 8.35
9.73
9.46
45
56
57
Y 160M1-2
YB
11
Y 160M2-2
YB
15
Y 200L1-2
YB
30
CQB-G 100-80-160 60
100
120
35
32
28
4.0
4.0
4.5
2900 12.43
15.85
16.34
46
55
56
Y 160L-2
YB
18.5
Y 180M-2
YB
22
Y 200L1-2
YB
30
CQB-G 100-65-200 60
100
120
54
50
47
4.0
4.0
4.5
2900 21.01
25.69
28.44
42
53
56
Y 200L1-2
YB
30
Y 220L2-2
YB
37
Y 225M-2
YB
45
CQB-G 100-65-250 60
100
120
86
80
74.5
4.0
4.0
4.5
2900 37.98
45.39
49.69
37
48
49
Y 250M-2
YB
55
Y 280S-2
YB
75
Y 280M-2
YB
90