Welcome Customer !

Membership

Help

Beiqi International Trade (Beijing) Co., Ltd
Custom manufacturer

Main Products:

ag-mach>Products
Product Categories

Beiqi International Trade (Beijing) Co., Ltd

  • E-mail

    phq@kitazaki.cn

  • Phone

    15510102388

  • Address

    406B, Building 1, Block A, Zhubang 2000 Business Building, Chaoyang District

Contact Now

AND electronic scale wholesale

NegotiableUpdate on 01/18
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

GX-32001M-AND Dustproof and Waterproof Electronic Balance Kitasaki International Advantages Business: Temperature and Humidity Meter, Electronic Analysis Balance, Precision Electronic Balance, Portable Desktop Scale, Density Balance, Pipette Calibration Balance, Moisture Analyzer, Viscometer, Vibration Rheometer, Waterproof and Dustproof Platform Scale, Waterproof and Dustproof Desktop Scale, Weighing Sensor, Weighing Control Display, Programmable Measurement Controller, Ultrasonic Thickness Gauge, etc.

Product Details

GX-32001M-AND dustproof and waterproof electronic balance


防尘防水中量级电子天平GX-M系列/GF-M系列(A&D阿波罗)Image


防尘防水中量级电子天平GX-M系列/GF-M系列(A&D阿波罗)Image

GF-32001M

防尘防水中量级电子天平GX-M系列/GF-M系列(A&D阿波罗)Image

Dust proof image

防尘防水中量级电子天平GX-M系列/GF-M系列(A&D阿波罗)Image

Waterproof image

GX-32001M-AND dustproof and waterproof electronic balance
内置重量型 GX-M系列

Basic GF-M series

  • Wide selection
    0.01g (8.2kg) -0.1g (32.2kg) for all 14 models

  • The all-new A&D Apollo high-capacity GX-M/GF-M series,Dustproof and waterproof rating IP65, capacity 32.2kg,
    Rich interfaces and troubleshooting solutions suitable for embedded applications.

  • washable
    Anxin "IP65 dustproof and waterproof" ensures that when weighing powders and liquids, Anxin not only has the scale pan and scale pan bracket, but also the rear of the body frame can be disassembled, making cleaning and washing easy.

  • Scale pan with shock absorber mechanism, allowing you to cope with impact with peace of mind
    The structure with a shock absorber mechanism on the back of the scale can reduce the impact on the sensor.

  • Integrated into the production line
    ISD: Impact detection: When the scale pan is impacted, a level 4 warning display and buzzer will sound to notify.

  • Used to check the repeatability and minimum of the balance
    Weighed ECL
    It only takes 90 seconds to calculate repeatability

  • Used for measuring liquid such as pump flow rate
    FRD: Flow Display
    Calculating load changes as "flow" can achieve high-precision flow measurement through a balance alone


industry... 3 new features .. ISD / ECL / FRD

ISD during integration into the production line: impact detection

A level 4 warning display and buzzer will notify you of the production line when the scale pan is impacted
: Easily check the degree of impact on the workpiece → Improve work efficiency during installation/prevent balance failure after installation
Research purpose: To prevent malfunctions of the balance due to impacts and deviations in weighing values during use, ensuring weighing accuracy
Impact level warning display+log function: Record impact levels 3 and 4 (50 data points)


Easily check the "impact level" that is difficult to measure.When it is subjected to strong impact, a warning will be issued, so you can use it with confidence.

ECL: Electronic Control Load (Self Test) Function, used to check the repeatability and minimum weighing value of the balance

  • Thanks to the internal mechanism of the balance, the repeatability (standard deviation SD) of the balance can be measured and calculated without the need for external weights.

  • Fault diagnosis and diagnostic function, check whether the balance runs well in its installation environment (display "OK" when SD is within the specification range)

  • Automatically measure within approximately 90 seconds

Production line: Accuracy confirmation in harsh installation environments, such as loading it into the production line and weighing and calculating it with a small load → even when working (tare weight)
It can also be calculated in the case of overload of Daiwa's built-in weights
Research purpose: Ventilation chambers are used to examine the effects of wind and vibration, and to check the minimum weight when used in crane or balance enclosures

By using the 'minimum weighing value alarm function', it is possible to determine at a glance whether the sample size meets the set minimum weighing value(onlyThe 'g' mode. In addition to the values calculated by ECL, they can also be set arbitrarily
.)

Used for measuring liquid FRD such as pump flow: flow display

Using the change in load as the "flow rate", high-precision flow measurement can be carried out through a computational balance.Due to the waterproof nature of the balance, there is no problem even if liquid splashes onto the main unit.
Production line: Improve the accuracy and stability of conveying pumps and measuring devices (liquids and powders), etc
Research application: Control the flow rate of solutions added to cell culture media, etc.

Flow measurement data processing software "WinCT-FRD"

The flow changes can be displayed in real-time in the form of charts, and the weighing values and flow values can be displayed on two axes simultaneously.

Allow adjustment of balance characteristics and weighing speed

WinCT GXA Filter is a data communication software that can adjust the weighing speed of a balance.
You can set internal filters, zero tracking, averaging, etc.
The setting data can be read from the balance and changed at once.
Settings can be saved in CSV file format.
You can read the saved CSV file and write the settings to the balance.
You can turn on/off the extension function (detailed filter settings).

specialty

Can be safely cleaned

Dustproof and waterproof rating IP65, even weighing powders and liquids can be done with peace of mind. Not only the scale pan and scale pan bracket, but also the rear of the main frame can be disassembled, making cleaning and washing easy.

Impact resistant safety

The scale pan with shock absorber has a shock absorber on the back, which can reduce the impact on the sensor.

Comparator function

Less, just right, more "is displayed as [Lo, Ok, Hi].Convenient packaging and arrangement work (3/5 steps).
You can also output the comparison results and enlarge them for display on the host.

Automatic power on/off function

This function can be turned on or off through internal settings (or controlled through commands from the PLC, etc.).
Example: When the power supply of the built-in device is turned on ⇒ When the day is powered on, the power supply of the balance is turned on.

Equipped with 2ch output as standard, it can connect to both PC and printer simultaneously PLC、 External monitor, etc. 2ch.

  • RS-232C interface (D-Sub9P male)

  • USB interface (mini B-type), including USB cable (1.8m)

Wireless communication can also be achieved by connecting the optional AD-8529 Bluetooth converter to RS-232C.

Usage example: USB connected to PC, RS-232C connected to printer, external monitor or PLC → Output scale
Quantity to PC and printer
→ Use PC to control the balance/print out the measured values with a printer
→ Use a PC to control the balance with an external display or input the measured value into the PC while monitoring

Password function

  • Security features that restrict balance users and clock settings

  • 3 steps to enter password before using the balance: Administrator/User/Guest

Statistical calculus

Statistically process the weighing values and display/output the results.

Proportion meter mode

Calculate and display/output the specific gravity of solids or liquids.

UFC Function (Universal Flex Coms)

You can set any output format.

Mao Net Tar Weight Mode

It can be zeroed and peeled separately, and can output gross weight, net weight, and tare data.

Simulated output of weighing results

The optional analog voltage output (GXM-06) can achieve 0-1V (or 0.2-1V) output.It can be effectively used to control external devices (not waterproof).
The analog output is updated according to the display refresh cycle.The display rewrite cycle can be changed through the internal settings of the balance (approximately 5 times/second, approximately 10 times/second, and approximately 20 times/second).

USB functionality

  • Can switch between one-way and two-way through internal settings

    • Unidirectional (quick USB): No need to install drivers, output directly to PC
      Alphabet can also output, supporting GLP output and statistical calculation output

    • Bidirectional communication: Data can be collected through data processing software WinCT
      Two way communication requires the installation of a "virtual serial port mode" driver program.

clock function

During GLP output and data storage, date and time data can be output and stored

Floor weighing

Standard underfloor weighing bracket

display mode

G (grams), PCS (quantity),% (percentage), ct (carats), mom (unit of pearl measurement), DS (specific gravity)

Data memory function

Weighing values: up to 200 (up to 50 per unit mass (piece)/up to 50 in calibration history)
Comparator setting values (upper and lower limits): up to 20/tare weight values up to 20

Specification: Built in weight GX-M series

Minimum display of 0.01g model

type name GX-8202M GX-8202MD GX-10202M
称重能力 8.2 kilograms 8.2 kilograms 10.2 kilograms
MIN represents 0.01 grams 0.01g(0~2.2kg)
0.1g(2.2~8.2kg)
0.01 grams
repetitiveness
(Standard deviation)
0.01 grams 0.01g(0.05g) 0.01 grams
Straightness ±0.03g ±0.02g(±0.1g) ±0.03g
stabilization time
(Representative value when set to FAST)
About 1.5 seconds About 1.5 seconds About 1.5 seconds
scale pan size 270×210mm 270×210mm 270×210mm
Material of measuring dish SUS316 SUS316 SUS316
Body quality About 9.3 kg About 9.3kg About 9.3kg

MIN displays 0.1g model

type name GX-12001M GX-22001M GX-32001M GX-32001MD
称重能力 12.2 kilograms 22.2 kilograms 32.2 kilograms 32.2 kilograms
MIN represents 0.1g 0.1g 0.1g 0.1g(0~6.2kg)
1g(6.2~32.2kg)
repetitiveness
(Standard deviation)
0.1g 0.1g 0.1g 0.1g(0.5g)
Straightness ±0.2g ±0.2g ±0.2g ±0.2g(±1g)
stabilization time
(Representative value when set to FAST)
About 1.5 seconds About 1.5 seconds About 1.5 seconds About 1.5 seconds
scale pan size 270×210mm 270×210mm 270×210mm 270×210mm
Material of measuring dish SUS316 SUS316 SUS316 SUS316
Body quality About 9.3 kg About 9.3kg About 9.3kg

Approximately 9.3kg





















Basic specifications GF-M series

MIN shows 0.01g model

type name GF-8202M GF-8202MD GF-10202M
称重能力 8.2 kilograms 8.2 kilograms 10.2 kilograms
MIN represents 0.01 grams 0.01g(0~2.2㎏)
0.1g(2.2~8.2㎏)
0.01 grams
repetitiveness
(Standard deviation)
0.01 grams 0.01g(0.05g) 0.01 grams
Straightness ±0.03g ±0.02g(±0.1g) ±0.03g
stabilization time
(Representative value when set to FAST)
About 1.5 seconds About 1.5 seconds About 1.5 seconds
scale pan size 270×210mm 270×210mm 270×210mm
Material of measuring dish SUS316 SUS316 SUS316
Body quality About 8.3 kg About 8.3kg About 8.3kg

MIN displays 0.1g model

type name GF-12001M GF-22001M GF-32001M GF-32001MD
称重能力 12.2 kilograms 22.2 kilograms 32.2 kilograms 32.2 kilograms
MIN represents 0.1g 0.1g 0.1g 0.1g(0~6.2㎏)
1g(6.2~32.2㎏)
repetitiveness
(Standard deviation)
0.1g 0.1g 0.1g 0.1g(0.5g)
Straightness ±0.2g ±0.2g ±0.2g ±0.2g(±1g)
stabilization time
(Representative value when set to FAST)
About 1.5 seconds About 1.5 seconds About 1.5 seconds About 1.5 seconds
scale pan size 270×210mm 270×210mm 270×210mm 270×210mm
Material of measuring dish SUS316 SUS316 SUS316 SUS316
Body quality About 8.3kg About 8.3kg About 8.3kg About 8.3kg